radiation detected

Download Report

Transcript radiation detected

Radiation. Safety.
Portable Instruments & Area Monitors
Radiation. Safety.
Portable Instruments | Smart Meters: RDS-31
radiation detected:
• Gamma and X-ray: 48 keV to 3 MeV
detector(s):
• internal energy-compensated GM tube
• smart external detectors
• Frisker
• GM Tube
• Silicon Diode (60 keV to 6 MeV)
measurement range:
• dose rate: 0.01 μSv/h to 0.1 Sv/h (1
μRem/h to 10 Rem/h)
• accumulated dose: 0.01 μSv to 200 Sv (1
μRem to 20,000 Rem)
Alarm indicators:
• Visual (LED), audible (speaker), tactile
(vibration)
•Optional internal WRM2 radio (900 MHz and 2.4 GHz)
Radiation. Safety.
Portable Instruments | Smart Meters: RAMR-200
radiation detected:
• Gamma and X-ray: 60 keV to 2 MeV
detector:
• energy-compensated GM tube
• External Smart Detectors (Frisker,
High range GM detectors)
measurement range:
• dose rate: 0.01 mSv/h to 1 Sv/h (10
μRem/h to 100 Rem/h)
• accumulated dose: 0.01 mSv to 800 Sv
(10 μRem to 80,000 Rem)
alarms:
• User-adjustable setpoints for dose rate
and accumulated dose
Radiation. Safety.
Portable Instruments | Handheld: TelePole WR
radiation detected:
• Gamma and X-ray: 70 keV to 2 MeV
detector:
• two energy-compensated GM tubes
measurement range:
• dose rate: 0.5 μSv/h to 10 Sv/h (0.05
mRem/h to 1,000 Rem/h)
• accumulated dose: 0.01 mSv to 800 Sv
(10 μRem to 80,000 Rem)
additional:
• Data-logging functionality
• Short Pole option
• Alarm setpoints for dose rate and
accumulated dose
•WRM2 transmitter option
Radiation. Safety.
Portable Instruments | Handheld: RDS-30
radiation detected:
• Gamma and X-ray: 48 keV to 1.3 MeV
detector:
• energy-compensated GM tube
measurement range:
• dose rate: 0.01 μSv/h to 100 mSv/h (1
μRem/h to 10 Rem/h)
• accumulated dose: 0.01 μSv to 1 Sv (1
μRem to 100 Rem)
alarm levels:
• User-adjustable alarm setpoints for dose
rate and accumulated dose
Radiation. Safety.
Portable Instruments | Handheld: AMP 50/100/200
Common characteristics:
•
•
•
•
•
Gamma and X-ray: 70 keV to 2 MeV
Waterproof probe head
Optional WRM2 External Transmitter
Optional cable lengths (25 to 250 feet)
AC and battery powered
AMP-50:
• 0.1 μSv/h to 40 mSv/h (10 μRem/h to 4
Rem/h)
AMP 100:
• 0.5 mSv/h to 10 Sv/h (5 mRem/h to 1,000
Rem/h)
AMP 200:
• 0.5 mSv/h to 100 Sv/h (5 mRem/h to
10,000 Rem/h)
Radiation. Safety.
Portable Instruments | Handheld: RDS-80A
radiation detected:
• Alpha: >2 MeV
• Beta: >100 keV
• Gamma and X-ray: 5 keV to 1.3 MeV
detector:
• End window GM tube
• 1.5 to 2 mg/cm2 MICA window
measurement range:
• 1 CPM to 100,000 CPM
• 0.1 DPM to 1,000,000 DPM
Alarm indicators:
• Visual (LED) and audible (speaker)
Radiation. Safety.
Portable Instruments | New Ion Chamber – RI02
Radiation. Safety.
Portable Instruments | Area Monitors: DRM-1
radiation detected:
• Gamma and X-ray: 70 keV to 2 MeV
detector:
• two energy-compensated GM tubes
measurement range:
• dose rate: 0.5 μSv/h to 10 Sv/h (0.05 mRem/h
to 1,000 Rem/h)
• accumulated dose: 0.01 mSv to 800 Sv (10
μRem to 80,000 Rem)
Alarm Indicator:
• Separately locatable alarm module includes
dose rate display, Speaker, and bright Red /
Green lamps
• Integrated WRM2 transmitter (900 MHz or 2.4 GHz)
Radiation. Safety.
Portable Instruments | Area Monitors: DRM-2
DRM-2:
• 0.5 μSv/h to 10 Sv/h (0.05 mRem/h to 1,000
Rem/h)
• Two energy-compensated GM tubes
• Integrated WRM2 transmitter (900 MHz or 2.4 GHz)
Display with audible and visual alarms
• AC and battery-backup powered
DRM-2D:
• 0.01 μSv/h to 100 μSv/h (1 μRem/h to 10
mRem/h)
• One CsI detector
• WRM2 Radio
• Display with audible and visual Alarms
• AC and battery-backup powered
• Integrated WRM2 transmitter (900 MHz or 2.4 GHz)
Radiation. Safety.
Portable Instruments | Area Monitors: DRM-2E
radiation detected:
• Gamma and X-ray: 70 keV to 2 MeV
detector:
• two energy-compensated GM tubes –
externally locatable into inhospitable areas
measurement range:
• dose rate: 0.5 μSv/h to 10 Sv/h (0.05
mRem/h to 1,000 Rem/h)
• accumulated dose: 0.01 mSv to 800 Sv (10
μRem to 80,000 Rem)
additional:
• Integrated WRM2 transmitter (900 MHz or 2.4 GHz)
• External detector can be located 25 feet to
250 feet away from the meter
Radiation. Safety.
Portable Instruments | RDS-31iTx-AM
Radiation. Safety.
Area Monitors | Perimeter Systems – Near Boundary Monitor
• Integrated DRM-2
detection: 0.5 μSv/h to 10
Sv/h (0.05 mRem/h to
1,000 Rem/h)
• WRM2 radio or cell
modem transmission
• Solar-powered – no AC
required
• Back-up battery charges
in environments to -40oC
• Fully self contained
apparatus