G-Eye Extending your monitoring & control capabilities

Download Report

Transcript G-Eye Extending your monitoring & control capabilities

G-Eye
Extending your monitoring & control capabilities
Control and management solution for
datacenters, computer rooms and power equipments
G-Eye – Net SNMP, cellular, dry
contacts, temperature, power
measurements, environment monitor
G-Eye
19'
1U
•
Datacenters and server facilities, cellular sites and countless other locations
require continuous electrical power to function properly. G-Eye enable you to
ensure and monitor the electrical supply at any location, and many other
parameters. G-Eye is the perfect solution, offering total flexibility and
protecting business continuity, and can even be the answer for a remote site
in the Amazon forest!
•
G-Eye integrate power measurements and the monitoring and control of
UPS(s), environment sensors, dry contacts, and IT devices, all in a single
unique device, with built-in immediate alert capabilities via SMS/Mail/SNMP
trap/Popup. Works on LAN/WAN network.
Environment
Extreme environmental changes can dramatically
affect the operating capabilities of electrical systems.
G-Eye solution:
The unit accepts input from multiple temperature
sensors, enabling real-time monitoring of
temperatures at a number of sites. Alarm thresholds
(high and low) can be custom configured for each
sensor. When the temperature reading passes above
or below the permitted range, the unit immediately
issues an alarm message to defined recipients, such
as field technicians, indicating the specific critical
sensor.
Dry Contacts
A single, small malfunction at a site can lead to waste and/or
damages. The ideal approach is simple:
“Head off problems before they occur”.
G-Eye solution:
An input dry contact is an electrical circuit that connects to an external
device. The external device can open or close the circuit. The
G-Eye detects a change in the state of the circuit and issues an
alarm message to up to ten user-defined phone numbers. A wide
range of supported sensors, such as security/smoke /flood/motion,
can also be ordered with the unit.
An output dry contact is an electrical circuit that connects to an
external device and can be opened or closed at user command.
This enables the G-Eye user to control external devices; for
example: opening or closing a gate, turning a generator or an air
conditioner off or on.
Power/UPS
1) Vital electrical systems require backup units to supply power in
the event of a mains failure.
2) Wide electrical measurements capacity
G-Eye solution:
1)The unit has a built-in web interface enabling the user to browse
anytime and anywhere using an internal/external IP address.
The internal modem is programmed to immediately send an
alert to prearranged recipients when the UPS is in critical state
(battery low), while servers receive UDP messages and start
count-down before shutdown. Users can also check UPS’s
estimated backup time based on active load, via the web, and
monitor other parameters, including: input/output voltage
according to different phases of UPS, dc battery voltage,
frequency, battery temperature.
2) 0-5 Vdc analog inputs for high/low voltages and currents,
external accessories available for different need.
Users are instantly notified if any measurement exceeds userdefined thresholds. Additional inputs accept 4-20 mA, and a
kWh meter.
IT control
Are you instantly informed of server/switch/routers that suddenly
lose ping request? Can you be alerted in real-time if the CPU
load, physical/virtual memory or hard disc space is over-limit in
one of your 40 servers? Today it is possible to remotely connect
to each server and perform a manual shutdown when the site is
operating on UPS batteries. But after the ac failure is resolved,
why wait till morning and wake them manually when someone
somewhere in the world needs these servers overnight?! How
can you even be sure that the ac has been restored at all?
G-Eye solutions:
The unit can controls and monitors IT targets. User can configure
the IP address, server name, MAC address (retrieved
automatically), shutdown countdown length for ac failure/low
battery, and countdown time for "wake up" when regular ac
power is restored. User-defined number of ping checks, CPU
load, physical/virtual memory and hard disk usage limits, as well
as alarm status when one of these limits is exceeded.
GSM control
User controls the unit via simple SMS commands.
Alarm messages can be sent to different targets
depending on the type of alarm. Examples of control
commands: temperature, dryin, dryout, shutdown,
wake, it, power, humidity… . Some of them are of
course password protected.
Exclusive
G-Eye Solutions
Backup capability
Need:
To monitor devices in a remote location, and to be
alerted in the event of a power outage in the building,
which has no power backup system.
Solution:
G-Eye enables you to monitor a wide range of devices
and sensors remotely, and has a built-in battery
backup that enables it to notify you immediately via
SMS in the event of any irregularities, even during a
power outage.
High number of power
measurements
Need:
To monitor 16 different voltages and current measurements and the
frequency of two AC lines, and to be notified instantly when any
of the measurements are too high or too low.
Solution:
• G-Eye monitors up to 16 dc and ac voltages and currents and
two ac line frequencies.
• Real-time measurements are viewable on-line at any time.
• System generates instant notification of management and
technicians via email and/or SMS if any of the measurements
fall outside of their user-defined acceptable ranges.
Easy migration path
You are a satisfied user of G4, using it to perform
multiple monitoring, and control functions, but you
have exhausted G4's capacities – you need
additional input and output connections.
Solution:
Move up to the G-Eye – same great features as the G4,
but many more analog inputs for power
measurements, more input and output dry contacts,
plus battery backup. After configuring G-Eye for the
desired alarms, simply disconnect your inputs from
the G4, connect them to the G-Eye, and you're ready
to go.
Change your point of view
Server room
Smoke detector
SNMP trap
Air condition start operation automatically
Air Condition stop operation
GPRS/SMS Control
and Notification
G-Eye
AC Fail
Motion detector
Shutdown
Servers
Wake-up
Servers
AC Recovered
Alarm
DC > 380v
Door open
AC current >200A
Battery cabinet
High temperature
Leak detection
and notification
Control via SMS
• The G-Eye can send notifications up to 10 mobile phone numbers. Any
of these numbers can be granted full control over the unit if desired.
• A “status” SMS command returns a short description of the unit’s state.
• All critical commands require an SMS password and the originating
phone number must be defined via the web interface as being
authorized to issue commands.
• User can choose to receive periodic automatic status notifications.
Critical commands include:
• Shutdown server, wake up server, change dry contact status (open,
close, pulse), reboot.
Control via SMS commands
G-Eye
Added Values:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Support various UPS Manufacturer and all Gamatronic UPS & DC systems.
Monitors up to 32 Network devices (Servers, routers…)
Wake up delay (Wake On LAN).
Environment input measurements :
4 temperature sensors,2 humidity inputs,1 flood detector, 1 liquid level (4-20 mA).
2 Frequencies.
2 kWH meter inputs.
4 analog inputs ±60 mVdc / ±60 Vdc.
12 analog inputs 0–5 Vdc. External accessories available for stepping down high
voltages and high currents.
Up to 32 environmental sensors via dry contacts.
Up to 16 dry contact controlled devices.
1 internal Quad band cellular modem.
Auto response to events.
Full remote control via Web or mobile phone.
Event group notifications.
Event logs (256).
Remote
User
Site
Auto response
G-eye can automatically respond to events without
human intervention.
Environment
GSM:
Control and manage via
mobile phone
•Humidity
•Temperature
Http:
•Flood
•Liquid Level (4-20 mA)
Internal web server, history log,
friendly GUI for configuration
and instant access
•Input/Output dry contacts
Servers
•Check CPU load, Memory space and more
•Ping check
•Automatic Shutdown/wake-up in UPS
failures and immediate shutdown in critical
event
Power measurements
•UPS monitoring, Gamatronic DC systems
•AC/DC voltage/current
•Frequency
•kWH meter
SNMP:
Polling, trap to SNMP
manager software
Notification:
SMS, Emails and SNMP
traps
G-Eye
main
screen
G-Eye
main
screen
UPS P+
Internal web interface enables remote
access and friendly GUI.
G-Eye
IT devices
Thru SNMP, the cpu load, virtual /
physical memory and hard disc
space are constantly monitored.
User can configure different limits.