Slide 1
E1 Protection Switching Equipment
PRODUCT OVERVIEW
• E1 Protection Switching System provides
point to point 1+1 redundancy link support
between any 2 independent E1 ports or 2
groups of E1 ports connected via higher order
multiplexers.
• Each E1 redundancy switch (each E1 Switch card) supports one E1 link
• Upto 16, E1 links can be supported by a "pair" of E1 Protection Switching Systems.
Two E1 Protection Switching Systems are required (one at each end of the link) for
implementation of 1+1 redundancy solution.
• One E1 Protection Switching System must be configured as "Master" and installed at one
end of the E1 link.
• The other E1 Protection Switching System must be configured as “Slave” and installed at
the corresponding far end of the E1 link.
Confidential
Copyright, Valiant Communications Limited 2000-2005
Slide 2
E1 Protection Switching Equipment
FEATURES & HIGHLIGHTS
• Provides 1+1 E1 redundancy link (active+standby) between any two complementing
transmission mediums.
• Provides 1+1 E1 redundancy support to higher order multiplexers eg. E2, E3.
• System configuration & management interface through "CLI" text based commands.
APPLICATIONS
• Providing 1+1 alternate paths between any two Transmission medium (active+standby).
e.g:!
Fiber / Fiber.
!
Radio / Fiber.
!
Radio / HDSL
!
Fiber / HDSL etc.
Confidential
Copyright, Valiant Communications Limited 2000-2005
Slide 3
E1 Protection Switching Equipment
APPLICATION DIAGRAMS
DIAGRAM - 1
Confidential
Copyright, Valiant Communications Limited 2000-2005
Slide 4
E1 Protection Switching Equipment
DIAGRAM - 2
Confidential
Copyright, Valiant Communications Limited 2000-2005
Slide 5
E1 Protection Switching Equipment
DIAGRAM - 3
Redundancy for a group of E1 Ports connected to Higher Order Links (1+1)
Confidential
Copyright, Valiant Communications Limited 2000-2005
Slide 6
E1 Protection Switching Equipment
FRONT VIEW OF SHELF
Slot Assignment of E1 Redundancy Shelf
Front View (Left to Right)
Card Details
Part No.
Slot 1:
Power Supply Card
E1-010 (CBS50)
Slot 2 to Slot 17:
E1 Protection Switch Interface Card
E1-EPS-IC
Slot 18:
E1 Management Card (NMS)
E1-EPS-MC
Confidential
Copyright, Valiant Communications Limited 2000-2005
Slide 7
E1 Protection Switching Equipment
Technical Specifications
Power Supply Card
Input DC voltage
Range of input
Output voltages
Full Load Output Current
Input Voltage Reversal Protection
Over Current Protection
Short Circuit Protection
Under Voltage
Over Voltage
Efficiency at full load
Ripple at full load
Spike at full load
Power Consumption
-48V DC ( nominal )
-40V to -60V DC
+5V
18A@5VDC
Provided in the Card
20A for +5V
Current limit - 20A. Recovers on removal of short
< 4.5V
5.4V to 5.6V
>80%
<5mVrms
<50mV
120 Watts (Worst Case)
Mechanical Specifications
Rack Mounting
Height
Depth
Width
Weight
Standard 19 Inch. DIN Rack
133.33mm.
292mm.
483mm.
5.00 Kg.
Confidential
Copyright, Valiant Communications Limited 2000-2005
Slide 8
E1 Protection Switching Equipment
Equipment
Connector:
Impedance:
Compliance:
Framing:
Signal Pulse:
Number of E1 Ports per card:
RJ-45 (F)
120 Ohms
ITU-T G.703
ITU-T G.704
3.0 Volt - as per ITU-T G.703
1
E1 Interface Protected Link (Active):
Connector:
Impedance:
Compliance:
Framing:
Signal Pulse:
Number of E1 Ports per card:
Clock
RJ-45 (F)
120 Ohms
ITU-T G.703
ITU-T G.704
3.0 Volt - as per ITU-T G.703
1
Loop-timed (When E1 port is in use)
Internal / loop-timed (User selectable when
E1 port is not in use)
Confidential
Copyright, Valiant Communications Limited 2000-2005
Slide 9
E1 Protection Switching Equipment
E1 Interface Protected Link (Standby):
Connector:
RJ-45 (F)
Impedance:
120 Ohms
Compliance:
ITU-T G.703
Framing:
ITU-T G.704
Signal Pulse:
3.0 Volt - as per ITU-T G.703
Number of E1 Ports per card:
1
Clock
Internal / loop-timed (User selectable when E1
port is not in use)
Loop-timed (When E1 port is in use)
Confidential
Copyright, Valiant Communications Limited 2000-2005
Slide 10
VCL Products
 E1, Voice & Data Drop-Insert Multiplexer
 PRI ISDN (Q.931) Multiplexers
 E1 Intelligent Channel Banks
 E1 / T1 DCME (Digital Circuit Multiplication Equipment) - Voice Compression Equipment
 Thin Route DCME
 E1 / T1 Echo Cancellers
 E1 / T1 Digital Cross Connect
 T1 / E1 Converters
 E3, 34Mbps Multiplexer
 34Mbps Optical Line Transmission Equipment (OLTE)
 Digital Loop Carrier
 Remote Asset Management Systems
 STM-1 / STM-4 SDH Equipment
Thank you for your attention
For more details visit us at our Web Site at
http://www.valiantcom.com
71/1, Shivaji Marg, New Delhi - 110015, India
Phone: +91-11 5105 5601, +91-11 5105 5602, +91-11 5105 5603,
+91-11 2592 8415, +91-11 2592 8416, +91-11 2541 0053
Fax: +91-11 5105 5604, +91-11 2543 4300
E-mail: [email protected]
Copyright, Valiant Communications Limited 2000-2005
Confidential
Slide 11