FLOW INSTRUMENTS

Quality & Simplicity in Flow Measurement

BT11 Series Totaliser Quality & Simplicity in Flow Measurement

Introduction

Overview

The FBT11 progammable self powered flow totaliser is specifically designed for computing & displaying totals from flow meters or machinery with frequency, sine wave or pulse outputs.

The instrument simultaneously displays resettable (batch) total & a cumulative total in engineering units as programmed by the user.

Ultra low power consumption provides as much as 10 years of service from the replaceable 3.6V lithium battery.

The BT11 may also be powered externally by 8~24Vdc.

Direct on meter and panel mounting versions are available.

Features

FBT11 Features

Self powered, 8 digit LCD cumulative totaliser and large

  

digit resettable totaliser 20ºC to+ 80ºC operation Simple flow chart programming with English prompts PNP/NPN selectable non scaleable or scaled pulse output

IP66 / 67 (Nema 4X) weatherproof Reinforced Plastic

housing enclosure Extended battery life up to 8 to 10 years & can be externally powered by 8~24Vdc

   

Pin protected Programming Reverse Polarity protected.

Accepts universal pulse inputs.

Meter or remote mount.

Programming

Simple Programming

The FBT11 is fully user programmable and has selectable PIN protection for security.

Simple flow chart programming with English prompts enables less technically skilled users to configure the FBT11 with ease. Once in the program mode the scrolling prompts guide you through the entire programming routine greatly reducing the need to refer to the manual.

Output / Options

Pulse Output

The FBT11 output is NPN – PNP transistor link selectable for either non-scaleable pulse output to 5Khz or fully scaleable pulse output with a limit of 50hz. Both pulse outputs have a 50mA maximum drive capability.

Optional

Display backlighting ( needs external dc power for this option to illuminate )

Enviroments

The FBT11 is designed to suit harsh conditions in industrial or marine environments. The robust housing is weatherproof to IP66, UV resistant, glass reinforced with viton seals

FBT11 RT100 Series Universal Specifications Rate Totaliser

Display Configuration Signal Type Input Frequency Range K-Factor Range Engineering Units Custom multifunction LCD

 5 digit total (resettable) 7.5mm high display  8 digit accumulated total 3.6mm high display 3 programmable decimal points with both display lines Four tactile feedback keypad for flow chart entry of data with scrolling English prompts. User selectable 4 digit PIN set-up protection.

Programmable engineering units and decimal point location for both rate and total.

All programmed data is battery protected Universal pulse / frequency input compatible with reed switch, coil-sine, voltage pulse & Namur proximity detectors. Max input frequency is 5Khz for coils, 2.5Khz for hall effect & current pulse inputs, 2Khz for voltage pulse devices & 500Hz for Namur proximity sensor.

0.001 to 99999.999 with floating decimal point during K-factor entry Selectable as iltres, m3, kgs, gal, lbs, MLtr & Mgal or no units

FBT11 RT100 Series Universal Specifications Rate Totaliser

Decimal Points Power Supply Pulse Output Operating Temperature Mounting Conduit Entries Physical

Individually programmable from 0 to 3 positions for total and accumulated total.

3.6Vdc Self powered by replaceable Ultra Lithium batteries, life expectancy of 7to 10 years. External via regulated 8 to 24VDC Scaleable Pulse output max load 50mA and needs to be externally powered for this feature to operate.

Non-Scaleable pulse output NPN/PNP selectable transistor, represents one pulse out for each input pulse from the primary measuring element.

-20 ° C to + 80° C Wall or horizontal / vertical pipe mount (with optional brackets) Panel mount (all models) Direct on flow meter mount (may require optional adaptors) Self drill cable gland entry at base & rear of the enclosure Overall 85mm diameter x 45mm deep – weight 175gams

FRT12 Rate Totalizer Quality & Simplicity in Flow Measurement

Introduction

Overview

The FRT12 flow rate totaliser has been specifically designed to operate with pulse producing flow meters such as positive displacement, turbine and paddle-wheel sensors, without the need for external power.

Ultra low power consumption is a result of innovative design which provides may years of service from a replaceable lithium battery.

External power may be applied to interface with common controllers such as PLC's via the scaleable pulse output and/or optional analog output. Multipoint linearity correction of the flow meter input can be programmed to enhance flow sensor rangeability.

Features FRT12 Features

   Self powered, 8 digit total and accumulated total, 5 digit LCD instantaneous rate display 10ºC to+ 80ºC operation All data is retained in the event of power loss or battery removal  Simple flow chart programming with English prompts  PNP/NPN selectable scaled pulse output as standard  Robust IP67 (Nema 4X) Reinforced Plastic Enclosure with M20 x 1.5 electrical conduit connections or ½” NPT option

Features FRT12 Features

 Low frequency cut off  Extended battery life up to 8 years with unique programmable power  management function. Multipoint linearity correction. ( Up to 10 points, best under external power )  Loop powered 4-20 mA output and selectable PNP or NPN flow alarms  Multi functional dual flow inputs. ( A+B, A-B & A ÷B )

Flow meter B

Features

FLOMEC Function A - B

Flow meter A

Programming

Simple Programming

The FRT12 is fully user programmable and has selectable PIN protection for security.

Simple flow chart programming with English prompts enables less technically skilled users to configure the FRT12 with ease. Once in the program mode the scrolling prompts guide you through the entire programming routine greatly reducing the need to refer to the manual.

Outputs

Scaleable Pulse Output

A selectable NPN or PNP output with variable pulse width is provided to ensure compatibility with commonly used PLC inputs and counters. The default width of 300ms (frequency permitting) enable most PLC's to successfully scan the incoming pulses with standard input circuits, reducing need for the additional cost of high speed counter inputs.

Loop Powered 4 - 20 mA Output

An optional high resolution analogue output enables transmission of the instantaneous flow rate. During configuration the FRT12 will simulate the zero and span currents with a facility to digitally tune these values to match your secondary instrument .

Outputs

Flow Alarm Outputs

Optional NPN or PNP selectable high and low flow rate alarms have independently adjustable dead bands to provide application flexibility and enable connection to commonly used devices.

Enclosure Design

Thoughtful design enables the FRT12 to be mounted directly onto flow meters regardless of their orientation. Multiple conduit connection also reduce wiring restrictions simplifying and minimising installation costs.

Optional stainless steel mounting kits enable wall or pipe mounting with commonly available worm drive ring clamps.

FRT12 Specifications

Display Configuration Signal Type Input Frequency Range K-Factor Range Engineering Units Custom multifunction LCD

- 8 digit alphanumeric, 9mm (0.35") character height displays:  8 digit total (resettable)  8 digit accumulated total   5 digit instantaneous flowrate programming prompts and messages - Subscript text, 2mm (0.08") character height, annunciates functional status Four tactile feedback keypad for flow chart entry of data with scrolling English prompts. User selectable 4 digit PIN set-up protection.

Programmable engineering units and decimal point location for both rate and totals, time base, K-factor, rate dampening and power management function.

All data is E 2 PROM protected in case of power loss or battery failure.

Universal pulse / frequency input compatible with reed switch, open collector, Namur and sine wave with 20mV minimum P-P voltage (typical of turbine coils) 0 to 5 kHz (rate display minimum 0.25 Hz) 0.001 to 99999.999 with floating decimal point during K-factor entry Selectable as ltr, m3, kgs, gal, lbs or no units

FRT12

Rate Time Base Decimal Points Power Supply Pulse Output Linearisation Optional Analog Output Optional Alarm Outputs

Specifications

Selectable units, per second, minute, hour or day Individually programmable from 0 to 3 positions for rate, total and accumulated total.

3.6Vdc Self powered by replaceable Ultra Lithium batteries, life expectancy of 5 to 8 years depending on power management selection.

External via regulated 8 to 24VDC or optionally via the 4-20 mA output loop.

Optional: Universal AC/DC (110-240VAC) with SPST relays Scaleable NPN/PNP selectable transistor, 100 mA max. resistive load Auto ranging pulse width with 1:1 ratio, defaulting to a maximum of 300 ms.

Up to 10 flow rate and frequency coordinates can be entered to enhance flowmeter accuracy when externally powered (VDC or 4-20 mA loop) 2 wire 4-20 mA output, 12 to 24 VDC into 750 ohms @24VDC Resolution 0.1% of range, programmable zero and span with output simulation 2 x NPN / PNP selectable transistor outputs, low and high flow alarms with adjustable deadband, 100 mA max. resistive load

FRT12 Specifications

Optional Dual Inputs Enclosure Mounting Conduit Entries Operating Temperature

A+B, A-B or A  B, all outputs correspond to the flow computation IP67 (Nema 4X) UV resistant fibreglass reinforced plastic with stainless steel screws and viton o-rings seals.

109 mm (4.3") diameter x 46 mm (1.8") deep, 0.45 kg (250 grams) Wall or horizontal / vertical pipe mount (with optional brackets) Panel mount (all models) Direct on flowmeter mount (may require optional adaptors) 3 x M20 x 1.5 or 1 / 2 " NPT -20 to 80 o C (-4 to 176 o F)

FRT20 Rate Totaliser Quality & Simplicity in Flow Measurement

FRT20 Introduction

Overview

The FRT20 flow rate totaliser has a large digit display & has been specifically designed for computing & displaying flow rates & totals from flow meters with pulse, sine wave or frequency outputs.

The instrument displays resettable ( batch ) total, cumulative total and instantaneous flow rate in engineered units as programmed by the user Designed for the more rugged applications in mine sites & mobile installations, the FRT20 LCD display has a back light panel & large digits for distance viewing at night.

FRT20 Features FRT20 Features

 6 digit large LCD total & 8 digit cumulative      totaliser, 5 digit rate display.

10ºC to+ 80ºC operation.

Scaleable universal pulse or frequency inputs.

Non volatile memory.

Reverse polarity protection.

Simple flow chart programming with English prompts.

   Scaled pulse output LCD backlighting as standard.

Robust IP67 (Nema 4X) Aluminium field & panel mountable enclosure

FRT20 Programming

Simple Programming

The FRT20 is fully user programmable and has selectable PIN protection for security.

Simple flow chart programming with English prompts enables less technically skilled users to configure the FRT20 with ease. Once in the program mode the scrolling prompts guide you through the entire programming routine greatly reducing the need to refer to the manual.

RATE PROGRAM ENTER RESET ACCUM TOTAL

FRT20 Options

Flow Meter Options

The FRT20 can be mounted in various configurations including pipe mount, meter mount & panel mount kits are available.

The FRT20 is also available with a heavy duty facia protector shield where rugged applications warrant extra protection.

An extended life battery pack can be added & installed for those applications which cause heavy drain on the battery life.

meter mounts pipe mount panel mount facia protector

Dimensions

FRT20 Installation

Designed for the more rugged applications where metal enclosures are needed The FRT20 LCD display has a back light panel & large digits for distance viewing at night.

FRT20 Specifications

Display Configuration Signal Type Input Frequency Range K-Factor Range Engineering Units 2 lines of display with subscripts & icons

Accumulated total - 8 digit s 7mm high programmable to 3 decimal places Resettable Total - 6 Resettable digits 17mm high , 3 decimal places maximum Flow Rate – 5 digits to 3 decimal places Four tactile feedback keypad for flow chart entry of data with scrolling English prompts. User selectable 4 digit PIN set-up protection.

Programmable engineering units and decimal point location for both rate and totals, time base, K-factor, rate dampening and power management function.

All data is E 2 PROM protected in case of power loss or battery failure.

Universal pulse / frequency input compatible with reed switch, open collector, coil ( 15 mV P/P min ) Namur and other proximities 0.1hz to 5 kHz (with programmable low frequency cut -off) 0.001 to 99,999.999 ( scale or K-factor ) Selectable as ltr, m3, kgs, gal, lbs or no units

FRT20

Rate Time Base Decimal Points Power Supply Pulse Output Enclosure Operating Temperatures

Specifications

Selectable units, per second, minute, hour or day Individually programmable from 0 to 3 positions for rate, total and accumulated total.

3.6Vdc Self powered by replaceable Ultra Lithium batteries.

External via regulated 8 to 24VDC Optional: Extended life battery pack for heavy duty power applications NPN scaled pulse matches whole number of display ( pulse width mirrors pre-scaled incoming pulse IP66 / 67 ( Nema 4X ) powder coated aluminium -10 to +80 deg C ( 14 to 176 deg F )

FEB10 Series Batch Controller Quality & Simplicity in Flow Measurement

FEB10

Introduction

Overview

The FEB10 is a fully programmable high speed batch controller specifically designed to operate with common pulse producing flow meters such as positive displacement, turbine, mass, vortex or magnetic style. Power.

The instrument displays batch value, batch progress & cumulative total in engineering units as programmed by the user, it also logs the total number of batches performed and total volume dispensed.

The FEB10 scrolls messages to prompt the user at each stage of operation. Batch limiting and no flow detection are “safeguards” against erroneously high batch entries, loss of flow input signal or pump failure.

FEB10

Features FEB10 Features

   Large 8 digit batch & cumulative total LCD 10ºC to+ 80ºC operation Simple flow chart programming      Scaleable flow inputs Two Stage control Automatic over-run compensation PIN protected programming Missing Pulse (no flow ) Alarm  Maximum batch size limiting  Non volatile memory  Robust IP66/67 Reinforced Plastic Enclosure with M20 x 1.5 electrical conduit connections or ½” NPT option

FEB10

Outputs

Control Outputs

2 Independent outputs can be programmed to provide stepped control at the start and / or end of each batch.

DC powered models have two solid state control outputs, 1A NPN open collector, 24Vdc maximum.

An automatic over run compensation feature corrects for any batch errors attributed to slow closing valves. V2 V1

flow

No flow alarm

The FEB10 will monitor the flow situation for loss of flow meter input signal Control options V1 single stage V1 + V2 two stage

FEB10

Installation

* Vertical pipe mount

ECOBATCH

RUN ACCUM. TOTAL STOP BAT LOW gal BATCH PROG ACCUM TOTAL STOP RESET

Panel mount

Conduit entries have an integral moulded seal, to remove break seal out using suitable lever Cut a 106.5mm (4.2 ”) diameter hole in panel

Surface mount footprint

(use 4 screws supplied )

RATE TOTALISER

RUN ACCUM. TOTAL STOP BAT LOW gal PROGRA M ACCUM TOTAL RATE TOTAL

Wall mount using optional bracket set

96 mm ( 3.8 ” ) 42.6 mm ( 1.67 ” ) 18 mm ( 0.7 ” )

FEB10

V3.1 HOLD 3 2 1 TESTING DISPLAY 88888888 PROGRAM MODE ENTERED press Prog. key

PROG

to step through if PIN protected ENTER PIN PIN _ _ _ _ program levels CHANGE PIN No. Y / N NU PIN Y ~ N YES NO PIN _ _ _ _ RESET ACCUM TOTALS Y / N RESET Y ~ N SET ENGINEERING UNITS ENG UNIT Ltr gal m3 Ibs kgs (none) ENTER NUMBER PULSES PER DPt TOTAL SET DECIMAL POINTS 0 0.0 0.00 0.000

DPt ACCUM TOTAL 0 0.0 0.00 0.000

SET COUNT DIRECTION COUNT DN ~ UP START DELAY - RELAY 2 DELAY 000 ~ 999 seconds PRE STOP VALUE - RELAY 2 PRE 000 ~ 999 AUTOMATIC OVERRUN COMPENSATION A/COMP Y ~ N continued

Programming / Operation

hold Program & Stop keys for 5 secs to enter the program

PROG STOP PROGRAMING FLOW CHART Batch Set

TO CHANGE BATCH if incorrect ENTER BATCH QTY.

XXXXXXXX

EXISTING PROGRAM DETAILS ONLY K-factor (scale factor) is the number of pulses per unit volume or unit mass eg: 20.465 pulses / litre, gallon, kg etc.

SET MISSING PULSE TIME OUT T / OUT 00 ~ 99 seconds SET BATCH LIMIT XXXXXXXX NETWORK OPERATION N / WORK Y ~ N YES NO SET UNIT ID No.

ID No. X See page 13.

END Y ~ N NO YES Exit program mode

Batch Set

TO REPEAT BATCH

RUN B A T C H E N D RESET

TO ABORT TO PAUS E

STOP

TO RESUME

RUN

FEB10

CONTROLLER NETWORKING

FEB10 has a networking feature which allows up to 9 individual batch controllers to be networked together with each being connected to one common flow meter

(see opposite).

Typical applications are where one liquid is being dispensed to a number of individual outlets or a number of different liquids are to be batched via one common flow meter. Networking takes place when any one controller is started, at this point the flow meter input (count) is restricted to the controller in use, all other controllers will not count and their start function will be inhibited.

Installation

Flowmeter

Multi point batching

Ecobatch 1

ECOBATCH

Ecobatch 2 network loop

ECOBATCH V1

Valve

V2

Ecobatch 3

ECOBATCH V3

Ecobatch 4

ECOBATCH V4

Ecobatch 1

ECOBATCH Mix tank 1 Product 1 Mix tank 2 Mix tank 3 Multi product batching Product 2 Product 3 Mix tank 4

Ecobatch 2 network loop

ECOBATCH V1 V2

Ecobatch 3

ECOBATCH

Valves

V3

Flowmeter Ecobatch 4

ECOBATCH V4 Product 4

FEB10 Specifications

Display Input Signal Type K-Factor Range Control Outputs Alarm output Operating Temperature Power Requirements Engineering Units Status Interlocks

9mm High alpha numeric characters + subscripts Batch & Accumulated total - 8 digit programmable to 3 decimal places Pulse & frequency , reed switch, open collector, coil ( 15mV P-P min ) current, voltage, namur & other proximities. Max frequency 10Khz 0.001 to 9,999,999.999 with 3 floating decimals ( scale or K-factor ) Two 1Amp NPN open collectors, 24Vdc max.

No Flow Alarm – 1Amp open collector ( NPN/PNP selectable ) 24Vdc max.

-10 to +80 deg C 12 – 24 Vdc, 50mA Selectable as litres, m3, kgs, gallons, lbs or no units Batch status output, batch inhibit input, network looping.