Transcript FIRE SAFETY

FIRE SAFETY
Dean Fenton
Fire legislation has previously been
reactive- Examples include:
1985

1987
-
Bradford Fire - 58 Deaths
1960

1964
-
Top Storey Club Bolton – 19 deaths
-
Licensing Act 1964
1987
-
Kings Cross – 31 deaths
Fire Safety and safety at places
of sport regulations 1987

1989
Fire precautions (sub surface rail
station) regulations 1989
Every year there are more than 40,000 premises fires in
the UK, resulting in around 300 deaths and 9,000 people
injured.
Around 75% of School fires are started deliberately,
arson continues to be a serious issue for local authorities
and fire services.
The majority of Arsonists are aged between 10 and 19,
so tackling the problem involves educating school aged
children about the dangers of deliberate fire setting.
(Source – Early Intervention – Gordon Mott – Report 88).
National cost of fire in Schools
2000
2001
2002
2003
2004
2005
£65,000,000
£93,000,000
£96,500,000
£73,500,000
£83,000,000
£67,000,000
Source – Zurich Insurance Company (2006)
The Regulatory Reform
(Fire Safety) Order 2005
Affects all non domestic premises.
The order applies to England and Wales, it:
Revokes all other ‘fire legislation’ and fire
certificates.
• Creates a single regime for fire safety.
• Is enforced by the ‘fire service’.
Responsible Person
The ‘responsible person’ could be owner,
occupier or employer within a building.
Within RMBC owned buildings it is likely to
be a shared responsibility between the
Premises Management Section, The
Manager / Head Teacher / Most senior
person on site and the site manager.
Duty of the Responsible Person
Take precautions to ensure the safety of everyone.
Assess risks to the building and it’s occupants.
Record the information as soon as practicable.
The assessment must identify vulnerable people.
Risk of arson is to be taken into account.
Avoid risks or evaluate risks if they cannot be avoided.
Combat the risk at source.
Reduce the risk so far as is reasonably practicable.
Risk Assessment
Risk Assessments must be written,
available for inspection and reviewed and
monitored regularly.
The fire service cannot do risk assessments
for us but can advise on areas of
weakness.
Step 1 – Identify fire hazards
Sources of ignition / heat.
Sources of fuel.
Sources of oxygen.
The Fire Triangle
Oxygen
‘ a fire can only start
when all 3 are present’
Heat
Fuel
Step 2 - Identify people at risk
Lone workers eg. caretakers, cleaners
etc.
People who are unfamiliar with the layout
of the building eg. visitors.
People with disabilities / Young People
Step 3 – Evaluate, remove, reduce and
protect from risk
Evaluate the risk of a fire occurring.
Evaluate the risk to people from fire eg. spread of fire and smoke
within building (age of building etc)
Remove or reduce fire hazards eg. paper stored safely, litter,
appropriate use and maintenance of portable heaters etc.
Remove or reduce risks to people eg. safer products, safe storage,
housekeeping etc.
Detection and warning systems, fire fighting, lighting, signage,
maintenance, escape routes etc.
Step 4 – Record, plan, inform,
instruct and train
Record significant findings and action taken.
Prepare an emergency plan.
Inform and instruct relevant people.
Co-operate with others eg. multi occupied buildings.
Provide training – e.g. evacuation, fire
extinguisher etc.
Step 5 – Review and Revise
Keep the assessment under review.
Revise where necessary.
Vulnerable people
How will we get a vulnerable person from
the building in an emergency ?
Personal Emergency Evacuation Plans (PEEPS)
Once the alarm is activated – who does
what ?
You will need to designate roles to certain staff
eg. Registration, door security, assist vulnerable
persons to safety etc.
Water Extinguisher
Used for class ‘A’ fires eg:
wood / paper etc
Direct the jet at the base of the flame and
keep it moving across the area of the fire.
Seek out any hot spots after the main fire is
extinguished.
A fire spreading vertically should be
attached at it’s lowest point and followed
upwards.
Carbon Dioxide Extinguisher
Used for class ‘B’ and ‘E’ fires eg:
petrol and electrical
DO NOT hold the horn – it becomes extremely cold
during use.
DO NOT use in confined spaces as there is a
danger of asphyxiation.
Dry powder extinguisher
Used for class ‘A’, ‘B’, ‘C’, ‘E’ fires eg:
Wood, paper, petrol, gas, electrical
Liquid fires – direct the nozzle towards the near edge
of the fire. With a rapid sweeping motion drive the fire
towards the far edge until extinguished.
Electrical equipment – switch off the apparatus /
power supply if possible.
Foam Extinguisher
Used for class ‘A’ and ‘B’ fires eg:
Wood, paper, petrol etc
Direct the jet with a gentle sweeping movement, and
allow the foam to drop down and lie on the surface liquid.
DO NOT aim the jet directly into the liquid as this will
drive the foam beneath the surface and render it
ineffective. In addition it may splash the fire to the
surrounding area.
Fire Blanket
Ensure you are positioned between the
fire and the fire escape route / door.
Pull the tapes to remove the blanket from
it’s container.
Hold blanket by the handles and using as
a shield to protect your face completely
cover the fire.
Turn off the electric / gas supply.
Leave the area closing all fire doors
behind you and contact the fire brigade.
DO NOT remove a fire blanket for at least
30 minutes.
Finally
DVD – fire safety
Handouts
Evacuation chair - Demonstration
Any Questions?
Reference
Fire Risk Assessment for the building
where you work.
Fire safety log book for the building where
you work.