PROPORTIONAL VALVES - BASIC PRINCIPLES

Steve Skinner, Eaton Hydraulics, Havant, UK Copyright  Eaton Hydraulics 2000

BASIC SYSTEM 1)

Consider a simple hydraulic system consisting of a reservoir (A), electric drive motor (B), pump (C), relief valve (D), filter (E), flow control valve (F), directional control valve (G) and cylinder (H).

G F E D C A H 2)

Movement of the cylinder is controlled by the flow control valve (which determines the speed of movement) and the directional control valve (which determines which way the cylinder moves).

B

BASIC SYSTEM

When the cylinder speed.

solenoid valve is energised, the cylinder piston will extend or retract at a speed determined by the flow control valve. The solenoid valve itself therefore has no control over the

BASIC SYSTEM

A three position solenoid valve can: - extend the cylinder

BASIC SYSTEM

A three position solenoid valve can: - extend the cylinder - retract the cylinder

BASIC SYSTEM

A three position solenoid valve can: - extend the cylinder - retract the cylinder - stop the cylinder

The solenoid valve is therefore acting much like a switch in an electrical circuit.

In one position the light is switched off...

... and in the other position it is switched on but there are no intermediate states.

However, another type of switch can be used for controlling a light bulb known as a dimmer switch.

In this case, the switch can be turned to any position between fully off and fully on to vary the brightness of the bulb.

In this case, the switch can be turned to any position between fully off and fully on to vary the brightness of the bulb.

In this case, the switch can be turned to any position between fully off and fully on to vary the brightness of the bulb.

In this case, the switch can be turned to any position between fully off and fully on to vary the brightness of the bulb.

In this case, the switch can be turned to any position between fully off and fully on to vary the brightness of the bulb.

In this case, the switch can be turned to any position between fully off and fully on to vary the brightness of the bulb.

In this case, the switch can be turned to any position between fully off and fully on to vary the brightness of the bulb.

In this case, the switch can be turned to any position between fully off and fully on to vary the brightness of the bulb.

BASIC SYSTEM 1)

A proportional directional valve can be thought of as the dimmer switch equivalent of an electrical switch.

2)

The valve spool can now be moved not just to one of three discrete positions but anywhere in between.

The direction of the spool movement away from the central cylinder the piston.

position moves but still determines which way the the amount of spool movement also controls the speed of

BASIC SYSTEM

So in effect the proportional directional valve is acting as both a directional valve and a flow control valve.

SWITCHING SOLENOID VALVE

A conventional solenoid valve can be thought of as a simple switching valve.

It is controlled by some form of electrical device which simply switches the electrical current on or off.

SWITCHING SOLENOID VALVE

A conventional solenoid valve can be thought of as a simple switching valve.

It is controlled by some form of electrical device which simply switches the electrical current on or off.

SWITCHING SOLENOID VALVE

A conventional solenoid valve can be thought of as a simple switching valve.

It is controlled by some form of electrical device which simply switches the electrical current on or off.

PROPORTIONAL VALVE

A proportional directional valve however will be controlled by an electrical device more like a dimmer switch.

PROPORTIONAL VALVE

By varying the current to either solenoid, the be controlled.

amount of spool movement can be varied and hence the amount of flow through the valve can

PROPORTIONAL VALVE

By varying the current to either solenoid, the be controlled.

amount of spool movement can be varied and hence the amount of flow through the valve can

PROPORTIONAL VALVE

By varying the current to either solenoid, the be controlled.

amount of spool movement can be varied and hence the amount of flow through the valve can

PROPORTIONAL VALVE

By varying the current to either solenoid, the be controlled.

amount of spool movement can be varied and hence the amount of flow through the valve can

PROPORTIONAL VALVE

By varying the current to either solenoid, the be controlled.

amount of spool movement can be varied and hence the amount of flow through the valve can

PROPORTIONAL VALVE

By varying the current to either solenoid, the be controlled.

amount of spool movement can be varied and hence the amount of flow through the valve can

PROPORTIONAL SOLENOID F G C B A D E

So unlike a conventional solenoid valve, the electrical current flowing through the coil of a proportional valve needs to be regulated not just switched on or off.

The construction proportional of solenoid however similar to that of an on/off solenoid.

a is The solenoid consists of: - a coil (A) - a frame (B) - an armature (C) - a pole piece (D) - a push-pin (E) The armature is enclosed in a core tube (F) and the whole assembly material (G).

is often fully encapsulated in a plastic resin

PROPORTIONAL SOLENOID

When a voltage is applied to the coil connections, an electrical current will flow through the coil.

PROPORTIONAL SOLENOID 1)

In turn, the electrical current creates a magnetic field which is concentrated in the metal frame, pole piece and armature.

2)

There is however a gap in the magnetic circuit between the pole piece and armature so a force is created which acts to close this gap and complete the magnetic circuit.

PROPORTIONAL SOLENOID 1)

The push-pin connects the solenoid to the valve spool and normally moves the spool against a spring.

2)

coil.

The force created by the solenoid is determined by the strength of the magnetic field which itself is proportional to the current flowing through the

PROPORTIONAL SOLENOID

Increasing the coil current will increase the solenoid force and hence move the spool a greater amount against the spring.

PROPORTIONAL SOLENOID

Increasing the coil current will increase the solenoid force and hence move the spool a greater amount against the spring.

PROPORTIONAL SOLENOID

Increasing the coil current will increase the solenoid force and hence move the spool a greater amount against the spring.

PROPORTIONAL SOLENOID I F F I

The solenoid is designed so that the relationship between the solenoid force (F) and the coil current (I) is a linear one. This means that the solenoid force depends only on the coil current.

SWITCHING SOLENOID SPOOL

A further difference between a switching solenoid valve and a proportional valve is in the design of the spool.

SWITCHING SOLENOID SPOOL 1)

With a switching valve, the spool is designed to achieve minimum pressure drop when the valve is energised.

2)

Which would mean that to control low flow rates, the amount of spool opening required would be very small and difficult to control.

Q S S Q

PROPORTIONAL SPOOL Q 1)

A proportional valve spool therefore has wider lands with notches cut into the edges.

S S

PROPORTIONAL SPOOL 1)

A proportional valve spool therefore has wider lands with notches cut into the edges.

Q 2)

So although the maximum flow through the valve may be reduced (compared to a switching valve) low flows in particular are more easily controlled and the opening of the valve is more gradual.

S S

PROPORTIONAL SPOOL

Depending upon the maximum flow to be controlled, different spools can be fitted to a particular valve which have different shape, size or number of spool notches.

Q S S

DIRECT ACTING PROPORTIONAL RELIEF VALVE 1)

Proportional valves can also be used to control pressure. In this case a proportional solenoid is used to push a poppet against a seat via a spring. The greater the solenoid force the greater the pressure required to push the poppet off its seat and open the valve.

DIRECT ACTING PROPORTIONAL RELIEF VALVE 1)

Proportional valves can also be used to control pressure. In this case a proportional solenoid is used to push a poppet against a seat via a spring. The greater the solenoid force the greater the pressure required to push the poppet off its seat and open the valve.

2)

This provides a direct acting relief valve function but like most such valves, it is only possible to pass small flow rates through the valve.

TWO-STAGE PROPORTIONAL RELIEF VALVE

To control higher flow rates, the proportional acting relief valve can be used as the pilot stage of a two stage relief reducing valve).

direct (or

TWO-STAGE PROPORTIONAL RELIEF VALVE

To control higher flow rates, the proportional acting relief valve can be used as the pilot stage of a two stage relief reducing valve).

direct (or

BENEFITS OF PROPORTIONAL SYSTEMS

REMOTE CONTROL - CONVENTIONAL SYSTEM

In order to adjust the speed of an actuator in a conventional system, the flow control valve has to be mounted in a convenient or accessible position. This may often mean running high pressure hydraulic pipes to and from an operator’s desk.

REMOTE CONTROL - PROPORTIONAL SYSTEM

With a proportional system however, where control valve adjustment is electronic, only low-power electrical cables valve.

need to be connected between the operator’s desk and the

PLC REMOTE CONTROL - PROPORTIONAL SYSTEM

More commonly these days, machine control is carried out by a digital electronic controller. Here again, the ability to control proportional valves electronically provides a simple interface between the hydraulic system and the electronic controller.

PROPORTIONAL PRESSURE CONTROL

The use of proportional directional and pressure control valves means that can all be hydraulic functions of a machine (movement and force) controlled electronically.

SOLENOID VALVE RESPONSE TIME

A further benefit of proportional valves is the ability to electronically control the speed of operation of the valve.

SOLENOID VALVE RESPONSE TIME

0.015

S

Depending upon its size and voltage supply, a conventional switching solenoid valve will have an energisation response time of approximately 15 milli-seconds.

SOLENOID VALVE RESPONSE TIME

0.040

S

The de-energisation response time will be only slightly slower (typically around 25 ms) since the return spring produces less force than the solenoid .

PROPORTIONAL VALVE RESPONSE TIME

The speed of movement of a proportional valve spool however can be determined decreasing by the the electronic signal fed to the valve solenoid. By gradually increasing or the signal ramping), it is possible to achieve energisation and response (known de-energisation times several seconds.

as of

S

PROPORTIONAL VALVE RESPONSE TIME

1.000

S

The speed of movement of a proportional valve spool however can be determined decreasing by the the electronic signal fed to the valve solenoid. By gradually increasing or the signal ramping), it is possible to achieve energisation and response (known de-energisation times several seconds.

as of

PROPORTIONAL VALVE RESPONSE TIME

2.000

S

The speed of movement of a proportional valve spool however can be determined decreasing by the the electronic signal fed to the valve solenoid. By gradually increasing or the signal ramping), it is possible to achieve energisation and response (known de-energisation times several seconds.

as of

PROPORTIONAL VALVE RESPONSE TIME

3.000

S

The speed of movement of a proportional valve spool however can be determined decreasing by the the electronic signal fed to the valve solenoid. By gradually increasing or the signal ramping), it is possible to achieve energisation and response (known de-energisation times several seconds.

as of

LIFT EXAMPLE - CONVENTIONAL SYSTEM

The reason why it is useful to be able to control the speed of spool movement of a valve is to reduce shock in a system. This is achieved by controlling the acceleration and deceleration of the actuator. Suppose, for example, that the simple hydraulic system described earlier is used to operate a passenger lift in a hotel.

LIFT EXAMPLE - CONVENTIONAL SYSTEM

When the solenoid valve is energised to lower the lift, the valve spool will move across very rapidly. This means that the cylinder will accelerate very quickly up to its maximum speed (determined by the setting of flow control valve F). This sudden starting of the lift provides a very uncomfortable ride for its occupants.

F

LIFT EXAMPLE - CONVENTIONAL SYSTEM

Similarly, when the lift reaches its destination, the solenoid valve will shut off very rapidly causing a sudden stopping of the lift and again a very uncomfortable situation for the occupants. In real hydraulic systems, the shocks generated by sudden starting and stopping of actuators create high peak pressures which are one of the principle causes of fluid leakage.

LIFT EXAMPLE - PROPORTIONAL SYSTEM

If the solenoid valve and flow control valve are replaced with a proportional valve then not only can the speed of the lift be adjusted electronically, but also its stopping and starting can be controlled.

LIFT EXAMPLE - PROPORTIONAL SYSTEM

The proportional valve can be opened sufficiently slowly to provide a smooth acceleration of the lift up to its maximum speed.

LIFT EXAMPLE - PROPORTIONAL SYSTEM

And likewise the deceleration can be controlled by slowing down the speed of spool movement back to the centre condition.

MOTION CONTROL

In general therefore, proportional valves are capable of providing full motion control in terms of:

time

MOTION CONTROL

1. A smooth and controlled acceleration of an actuator up to its maximum speed.

Acceleration time

MOTION CONTROL

2. Control of the actuator velocity and if necessary maintaining it constant with varying loads.

Velocity Acceleration time

MOTION CONTROL

3. A smooth deceleration with minimal pressure peaks.

Deceleration Velocity Acceleration time

FORCE CONTROL Force

Proportional valves can also be used to control the force output from an actuator (for example in press or plastic injection moulding applications) by controlling the pressure applied to the actuator.

time

FORCE CONTROL Force

In such cases it is often necessary to control not only the maximum actuator pressure but also the rate at which the pressure is applied or removed.

time

FORCE CONTROL Force

In fact the machine cycle may consist of a series of ramps and holding periods all of which can be achieved with just the one proportional valve.

time

FORCE CONTROL Force

At the end of the machine cycle the rate at which the pressure is reduced is also critical in many processes.

time

FORCE CONTROL

Motion and force control can thus be achieved using proportional valves, and in some cases the same valve can be used for both motion and force control. This is usually referred to as ‘PQ’ control (P) and flow (Q).

ie.

the control of both pressure Furthermore, all these control functions can be achieved using electronic inputs to the valve thus providing a simple interface to the machine controller.

of

ELECTRONIC CONTROL

VALVE INPUT SIGNAL

As described earlier, the electrical current to the solenoid of a proportional valve needs to be regulated and not just simply switched on or off as is the case with a conventional valve.

VALVE INPUT SIGNAL

In theory, this could be achieved by using a dimmer switch type component (ie. a variable resistor). Practical problems such as heat generation and drift however mean that such a device would not normally be used except for the very simplest applications.

PROPORTIONAL VALVE AMPLIFIER

Normally, the current flowing through the proportional solenoid will be controlled by some form of electronic amplifier. The amplifier itself will require a power supply (usually 12 or 24 VDC) and a command input signal.

24 V DC

PROPORTIONAL VALVE AMPLIFIER

The output of the amplifier (electrical current) is controlled by the input signal so with zero input the output current is also zero.

24 V DC

PROPORTIONAL VALVE AMPLIFIER

Increasing the input signal to the amplifier results in a corresponding increase in output current to the valve solenoid.

24 V DC

PROPORTIONAL VALVE AMPLIFIER

Increasing the input signal to the amplifier results in a corresponding increase in output current to the valve solenoid.

24 V DC

PROPORTIONAL VALVE AMPLIFIER

Increasing the input signal to the amplifier results in a corresponding increase in output current to the valve solenoid.

24 V DC

PROPORTIONAL VALVE AMPLIFIER

The relatively large current required to drive the valve solenoid (typically 2 to 3 amps) is provided by the power supply so the current required from the input signal device is very small (normally just a few milli-amps). The input control device can therefore be a simple potentiometer.

24 V DC

PROPORTIONAL VALVE AMPLIFIER

In mobile applications the input device could by a joystick type potentiometer.

24 V DC

PROPORTIONAL VALVE AMPLIFIER

In an increasing number of applications however, the input signal is generated by the machine controller itself (eg. a PLC Programmable Logic Controller). This can then be fed directly to the valve amplifier to generate the appropriate output.

24 V DC

VALVE TYPES

NON-FEEDBACK VALVE

Different types of proportional valves with differing levels of performance are available to meet the requirements of a wide range of applications. The simplest type of proportional directional valve balances the solenoid force against a spring compression force in order to position the spool within the valve body.

NON-FEEDBACK VALVE

An input signal to the amplifier produces a corresponding output current to the valve solenoid. This current creates a force on the valve spool thus moving it across until the compression of the spring balances the solenoid force.

A small input signal thus creates a small opening of the valve.

NON-FEEDBACK VALVE

Increasing the input signal gradually opens up the valve and allows more flow to pass through...

NON-FEEDBACK VALVE

... until the valve is wide open and passing maximum flow.

NON-FEEDBACK VALVE 1)

For any input signal therefore, the spool is positioned by balancing solenoid force against spring force. In practice however, other forces also act on the spool. Flow forces in particular are generated when flow passes through the valve and these will act with the spring to oppose the solenoid force and thus reduce the amount of spool opening.

NON-FEEDBACK VALVE 1)

For any input signal therefore, the spool is positioned by balancing solenoid force against spring force. In practice however, other forces also act on the spool. Flow forces in particular are generated when flow passes through the valve and these will act with the spring to oppose the solenoid force and thus reduce the amount of spool opening.

2)

This simple type of valve will therefore have limitations both on the maximum flow rate it can pass and also with its performance in terms of accurate positioning of the valve spool.

FEEDBACK VALVE

Valve performance can be increased by adding a spool position sensor to the valve. This sensor provides an electronic feedback signal to the amplifier and thus allows the spool to be positioned much more accurately.

FEEDBACK VALVE

Increasing the input signal to the amplifier gradually opens the valve flow path.

FEEDBACK VALVE

Increasing the input signal to the amplifier gradually opens the valve flow path.

FEEDBACK VALVE

As before, flow forces will build up to oppose the solenoid force and attempt to reduce the spool opening. Any reduction in opening is now detected by the spool sensor however and results in an increased output current from the amplifier and an increased force from the solenoid to counteract the flow forces.

FEEDBACK VALVE 1)

As the pressure drop and flow rate through the valve increase further, ultimately the flow forces will overcome the solenoid force and act to reduce the valve opening as with the simple valve but this will now occur at a significantly greater flow rate than before. For a given size therefore, a feedback type valve will pass a greater flow than the equivalent non feedback valve and the spool positioning will be more accurate.

2)

The penalty for the improved performance however is a higher cost valve and the fact that the amplifier needs to be dedicated to the type of valve it is controlling (as opposed to a multi-purpose amplifier used on the non-feedback valve).

TWO-STAGE SOLENOID VALVE

When higher flow rates need to be controlled, a two stage valve becomes the most practical and larger solenoids).

solution (rather than fitting larger As with direct acting valves, a two-stage proportional valve has many similarities with its equivalent switching valve, but there are also significant differences.

TWO-STAGE PROPORTIONAL VALVE

Firstly, the main spool is modified to incorporate the spool metering notches as on the direct acting valves.

This provides a more controlled path.

opening and closing of the valve flow

TWO-STAGE PROPORTIONAL VALVE

Secondly, the pilot stage is modified of the so that the solenoid current varies the pressure created in the ports leading to either end main spool.

Effectively, the pilot stage operates as two proportional pressure reducing valves.

TWO-STAGE PROPORTIONAL VALVE

Thirdly, the main spool springs are replaced with just one spring. This means that the same spring is compressed whichever side of center the main spool is moved thus avoiding the need for two accurately matched springs.

TWO-STAGE VALVE (NON-FEEDBACK)

Finally, a pressure reducing module is sometimes fitted between the main stage and pilot stage to reduce the pilot pressure when operating at high system pressures (typically greater than 3000 psi).

TWO-STAGE VALVE (NON-FEEDBACK)

Energizing one of the pilot stage solenoids creates a pressure in one main spool end-chamber proportional to the solenoid current.

This pressure pushes the main spool across until the main spring compression force balances the pilot pressure force.

TWO-STAGE VALVE (NON-FEEDBACK)

Energizing the opposite solenoid moves the main spool in the other direction but still compresses the same main centering spring.

TWO-STAGE VALVE (SINGLE FEEDBACK)

When an increased level of performance is required, a spool position sensor can be fitted to the main spool and a single solenoid pilot stage used. As before however, this will increase the cost of the valve and require a dedicated amplifier.