Transcript Document
CBM Meeting ITEP 05.11.04 SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower SiPM main characteristics 42m 20m pixel h Resistor Rn=400 k Al Depletion Region 2 m R 50 Substrate Ubias Pixel size ~20-30m Electrical inter-pixel cross-talk minimized by: - decoupling quenching resistor for each pixel - boundaries between pixels to decouple them reduction of sensitive area and geometrical efficiency • Optical inter-pixel cross -talk: -due to photons from Geiger discharge initiated by one electron and collected on adjacent pixel Working point: VBias = Vbreakdown + DV ~ 50-60 V DV ~ 3V above breakdown voltage Each pixel behaves as a Geiger counter with Qpixel = DV Cpixel with Cpixel~50fmF Qpixel~150fmC=106e Dynamic range ~ number of pixels (1024) saturation SiPM Spectral Efficiency Depletion region is very small ~ 2m strong electric field (2-3) 105 V/cm carrier drift velocity ~ 107 cm/s very short Geiger discharge development < 500 ps pixel recovery time = (Cpixel Rpixel) ~ 20 ns Photon detection efficiency (PDE): - for SiPM the QE (~90%) is multiplied by Geiger efficiency (~60%) and by geometrical efficiency (sensitive/total area ~30%) - highest efficiency for green light important when using with WLS fibers Temperature and voltage dependence: -1 oC +4.2% in Gain * PDE*Xtalk +0.1 V +4.5% in Gain * PDE*Xtalk WLS fiber emission 40 One pixel gain M, 10 5 one pixel gain (exp. data) one pixel gain (linear fit) detection efficiency ( l =565nm) 15 30 10 20 5 10 operating voltage 0 0 0 1 Ubreakdown=48V 2 3 4 5 6 Overvoltage DU=U-Ubreakdown, V Photon detection efficiency = QEgeom Efficiencyof light registration , % 20 SiPM signal saturation due to finite number of SiPM pixels Individual tile energy reconstruction using calibration curve: SiPM signal vs energy deposited: Average number of photoelectrons for central tiles for 6 GeV 1000 250 1400 1200 LED Tile 1000 25 10 200 150 800 600 Counts 100 Counts SiPM signal 1600 100 400 50 200 0 0 200 400 600 TDC channel 800 1000 1200 1ch = 50 ps 1 1 10 100 1000 Number of phe 1 10 1 10000 100 Energy Deposited, MIP Very fast pixel recovery time ~ 20ns For large signals each pixel fires about 2 times during pulse from tile SiPM Noise noise rate vs. threshold random trigger 1p.e. 2p.e. Ped. 3p.e. 1p.e. noise rate ~2MHz. threshold 3.5p.e. ~10kHz threshold 6p.e. ~1kHz Optimization of operating voltage is subject of R&D at the moment. Experience with a small (108ch) prototype (MINICAL) Moscow SiPM cassette 3x3 tiles Tile with SiPM Hamburg Light Yield from Minical tiles (5x5x0.5cm3) Using triggered Sr source and LED at ITEP LED b N pixel Using electron beam at DESY (SiPM signals without amplification) Good reproducibility after transportation from Moscow to Hamburg LED and 90Sr signals Individual photoelectrons are clearly seen Light Collection Uniformity, Y11 MC 1mm fiber, Vladimir Scintillator, mated sides, 3M foil on top and bottom Reduction in light yield near tile edges is due to finite size of a b source Light yield drop between tiles acceptable (Calorimeter geometry is not projective) Cross-talk between tiles ~2% - acceptable Light collection efficiency 5x5x0,5cm3 mm Sufficient uniformity for a hadron calorimeter even for large tiles Acceptable cross-talk between tiles of ~2% per side Sufficient light yield of 17, 28, 21 pixels/mip for 12x12, 6x6, and 3x3 cm2 tiles (quarter of a circle fiber in case of 3x3 cm2 tile) Shower Shape 3 GeV e+ Black – data Yellow -MC After single tile calibration and smearing MC describes well shower shape NON-LINEARITY and ENERGY RESOLUTION for DIFFERENT BEAM POSITIONS 1,08 centerindiv side(0;+15) side(0;+25) side(+15;+15) 1,06 1,04 nonlinearity nonlinearity 1,02 A( Ei ) FIT( Ei ) For all cases the same fit function is used ! 1,00 0,98 SiPM 0,96 0,94 0,92 1 2 3 4 5 6 EnergyE[GeV] resolution 0,24 0,22 centerindiv side(0;+15) side(0;+25) side(+15;+15) 0,20 dE/E 0,18 0,16 0,14 0,12 0,10 0,08 1 2 3 4 E[GeV] 5 6 Beam position With universal SiPM calibration curve there is no differences in response for different beam positions (different SiPM saturation) Cassette, Absorber and Support Structure Cassette contains 220 tiles with SiPM and electronics There are 40 cassettes between 2cm iron absorber Altogether about 8000 tiles of 3x3, 6x6 and 12x12 cm2 with SiPM and individual readout Scan of Strip Using Cosmics Setup groove depth 2.5mm LED ∑ PoissXtalk·G(x0+i·Δx,0+1 ·√i) cosmics Center of strip, N pixels (peak) = 9.7 Scan of Strip Using Cosmics Setup (2) Strip 200x2.5x1cm3 Poisson mean for MIP at normal incidence MC: light yield for 4x1cm2 strip will be ~25% smaller. In the middle of 280x4x1cm3 strip we expect ~ 9p.e. With threshold 4.5p.e. • noise rate <10kHz • efficiency 98% • average efficiency >99% Similar detector - MRS APD - with smaller x-talk and similar efficiency is under investigation now. Expect efficiency >99.5% with noise <1kHz Metal-Resistor-Semiconductor APD (CPTA, Moscow) MRS APD Cross-talk MRS APD Efficiency vs. Wavelength Measurement of Scintillator Sensitivity to Neutron Background at BELLE Backup Slides Amplitude Dependence on Temperature T=+9.5oC T=+14.6oC T=+20.1oC T=+25.3oC Light Yield of Individual MINOS There is a substantial difference in individual strip responce. However all strips give more thanStrips 3p.e. at 3m. Sc. Nonuniformity across strip is about 5% only for 4cm x 1cm strips. SiPM SiPMs will be tested and calibrated with LED before installation into tiles (noise, amplification, efficiency, response curve, x-talk) PC driven generator LED driver Steering program Remote control 16 channel power supply DATA BASE ……. .. gate X~100 16 ch 12 bit ADC Tested SiPM 16 ch amp 16 ch 12 bit ADC Scheme of test bench for SiPM selection at ITEP Tiles will be tested with a triggered β source and LED before installation into cassette Test bench for tile tests at ITEP 16 chan amps 16 ch remote control power supply b -source 16 ch 12 bit ADC Steering program 16 sci tile plane step motor trigger counter movable frame DATA BASE discriminator gate Emission Spectrum of Y11 WLS Fiber Measured at distances 10cm, 30cm, 100cm and 300cm from source. Comparison of the SiPM characteristics in magnetic field of B=0Tand B=4T (very prelimenary, DESY March 2004) LED signal ~150 pixels A=f(G, , x) No Magnetic Field dependence at 1% level (Experimental data accuracy) Long term stability of SiPM 20 SiPMs worked during 1500 hours Parameters under control: •One pixel gain •Efficiency of light registration •Cross-talk •Dark rate •Dark current •Saturation curve •Breakdown voltage No changes within experimental errors 5 SiPM were tested 24 hours at increased temperatures of 30, 40, 50, 60, 70, 80, and 90 degrees No changes within experimental accuracy