Transcript שקופית 1
FlowLine Bipore® Heparin JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Product Description FlowLine Bipore vascular graft heparin coating of inner surface medical device class III wall thickness: 0,4 mm (thin wall) 0,7 mm (standard wall) length: 100 - 1000 mm diameter: 5 - 10 mm helical PTFE-monofilament reinforcement JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Product Description guideline: JOTEC FlowLine Bipore Heparin Xmm TW coating not visible shelf life: 2 years no resterilization nomenclature: i.e. 15TW6006S FlowLine Bipore Heparin length JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net diameter S: fully reinforced N: no reinforcement FlowLine Bipore® Heparin Product Description additional label FlowLine Bipore Heparin Heparin covalent bonded JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Indications Same indications as FlowLine Bipore® primarily in the periperal vascular region - femoralpopliteal - axillofemoral - iliacoiliacal - tibial and peroneal arteria arteriovenous shunt prothesis in hemodialysis JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Contraindications same contraindications as FlowLine Bipore® patients with hypersensitivity to heparin HIT Type II (heparin-induced thrombocytopenia) - immunologic disease - activation of platelets in presence of heparin - 0,5 - 3% of patients after dosage of 20.000 IU/d - occurence within 20 days - decrease of platelets < 50% - thrombosis and bleeding JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Thrombocytopenia lower incidence of HIT Type II with porcine heparin than with bovine heparin (0.4% vs 1.6%) dependent of applied heparin dose Thrombocytopenia (<50 000 / µl) Thrombocytopenia (<100 000 / µl) Thrombotic Complications Full-Dose Heparin (> 20.000 IU/d) 7/981 (0,7%) 26/1080 (2,4%) 4/1080 (0,4%) Low-Dose Heparin (< 15.000 IU/d) 0/362 (0%) 1/362 (0,3%) no Number of patients Warketing T., Kelton J., Prog Hemost Thromb 10, 1-34, 1991 JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Thrombocytopenia Coating of FlowLine Bipore Heparin heparin from porcine intestinal mucosa release of at most 20 IU in the case of largest graft no complications may be expected! JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Heparin in General physiological coagulation inhibitor liver, lung and intestinal mucosa physiological blood concentration: 100 µg/l enzymatic degradation by Heparinase half-life: 90 – 120 min partially excretion by urine JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Functional Principle binding of Antithrombin III in the blood plasma inhibition of coagulation imitation of the antithrombotic effect of heparansulfate as in the case of the natural endothelium creation of a „blood friendly“ surface by binding of selected plasma proteins JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Established Heparin Coatings Name Producer Market entry Bonding Application Carmeda BioActive Surface® Medtronic 1985 covalent ECC, ventricular assist devices, central venous catheter, coronary stent, ePTFE vascular graft (Gore) Duraflo II® Baxter 1988 ionic Bioline Coating® Jostra AG 1992 covalent with ionic interaction JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net ECC ECC, centrifugal pump, catheter, canules, tubes FlowLine Bipore® Heparin Heparin Coating of Vascular Grafts InterVascular InterGard™ Heparin W.L. Gore & Associates GORE-TEX® PROPATEN Vascular Graft JOTEC FlowLine Bipore® Heparin JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Product Comparison Product name InterGardTM Heparin GORE-TEX® Propaten FlowLine Bipore® Heparin Material Heparin Polyester porcine / Collagen high molecular Bonding Registration ionic 1991 ePTFE porcine / low molecular covalent 2002 ePTFE porcine / high molecular covalent with ionic interaction 2003 JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Structural Comparison InterGard™ Heparin GORE-TEX® PROPATEN ePTFE Polyester Collagen Heparin + Adhesive agent Activated surface FlowLine Bipore® Heparin Heparin Adhesive agent ePTFE JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net Adhesive agent Heparin FlowLine Bipore® Heparin FlowLine Bipore® Heparin – Coating ePTFE – Heparin Covalent bonding Adhesive agent JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net + FlowLine Bipore® Heparin InterGard™ Heparin – Coating ionic binding of high molecular heparin to polyester TDMAC (Tridodecyl-methyl-ammoniumchloride) as adhesive agent impregnation of heparinized polyester graft with collagen JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin InterGard™ Heparin Just a fractional amount of heparin in contact with blood after implantation! JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin InterGard™ Heparin in vitro stability of heparin coating over 4 weeks with minimal loss after 7 days prospektive randomized clinical trial in comparison to uncoated ePTFE vascular graft (Devine et al.J Vasc Surg 2001) • lower amputation rate (6 vs 17) • significantly higher patency rates JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin InterGard™ Heparin – Randomized Clinical Trial Product brochure InterGard Heparin P/N: 7366/2 JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin GORE-TEX® PROPATEN Vascular Graft – Coating heparin coating of ePTFE vascular grafts • surface activation • application of adhesive agent • covalent binding of low molecular heparin by end-point attachment interaction of active heparin sequences with circulating blood JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin GORE-TEX® PROPATEN Vascular Graft stability proven in vitro – marginal heparin release within 24 h improved patency rates after 6 months ( Fig. 1) • Test animal: dog • Implantation site: Arteria carotis shunt model • Ø: 3mm, length: no statement no thrombus formation on bioactive surface after implantation for 2 h ( Fig. 2) JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin FlowLine Bipore® Heparin – Coating alternating coating consisting of adhesive agent and high molecular heparin high heparin loading to the inner surface! synthetic protein as adhesive agent avoidance of toxic substances! covalent cross linking by EDC (carbodiimide) avoidance of toxic substances! covalent bonding and ionic interactions bioactive sequences freely accessible! stable bonding of heparin! JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin FlowLine Bipore® Heparin – Coating no effect on the graft handling • implantation technique • anticoagulation no modification of mechanical features of ePTFE graft JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Dynamic Blood Test Using a Chandler Loop Model ePTFE graft Ø: 6 mm, l: 50 cm 37 °C H.P. Wendel Clinical Research Laboratory, Dept. of Thoracic and Cardiovascular Surgery, University of Tübingen JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net blood: 18 ml heparin: 1,2 IU/ml contact time: 2h FlowLine Bipore® Heparin Dynamic Blood Test Using a Chandler Loop Model Platelets [x103/µl] C: Control P: ePTFE graft H: FlowLine Bipore® Heparin C P H C P H C JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net P H FlowLine Bipore® Heparin Dynamic Blood Test Using a Chandler Loop Model ePTFE graft after 2 hours of blood contact JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin after 2 hours of blood contact FlowLine Bipore® Heparin Comparison of Product Range JOTEC vs GORE-TEX JOTEC Thin Wall, w/o reinforcement Length [cm] Gore Thin Wall, w/o reinforcement Ø [mm] Catalogue-No. 40 5 15TW4005N not available 50 6 7 8 15TW5006N 15TW5007N 15TW5008N 6 not available 8 80 6 7 8 15TW8006N 15TW8007N 15TW8008N 6 not available 8 JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin Comparison of Product Range JOTEC vs GORE-TEX JOTEC Thin Wall, reinforced Gore Thin Wall, reinforced Length [cm] Ø [mm] Catalogue-No. 40 5 15TW4005S not available 50 6 7 8 15TW5006S 15TW5007S 15TW5008S not available not available not available 70 5 15TW7005S not available 6 80 6 7 8 15TW8006S 15TW8007S 15TW8008S 6 not available 8 JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin JOTEC Product Range Thin Wall w/oreinforcement Standard Wall reinforced w/o reinforcement L [cm] Ø [mm] L [cm] Ø [mm] L [cm] Ø [mm] 10 5 10 5 20 6 7 40 5 40 5 40 5 50 6 7 8 50 6 7 8 70 5 70 5 80 6 7 8 80 6 7 8 JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net reinforced L [cm] Ø [mm] - - 50 6 7 8 50 6 7 8 70 5 - - 80 6 7 8 - - FlowLine Bipore® Heparin Product Advantages coating of inner surface no toxic substances stable covalent binding of heparin bioactive heparin sequences freely accessible high permanent hemocompatibility widest product spectrum JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin GORE-TEX® PROPATEN Vascular Graft Product brochure GORE-TEX PROPATEN June 2002 Fig. 1 JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net FlowLine Bipore® Heparin GORE-TEX® PROPATEN Vascular Graft Product brochure GORE-TEX PROPATEN June 2002 Fig. 2 JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany, www.jotec.net