No Slide Title

Download Report

Transcript No Slide Title

Stowood Scientific
Instruments
Oxford OX3 9UP
Download 2001
A Trend Reporting and
Analysis System for
Pulse Oximeters
Download 2001 Chart Display
Overview

Download 2001 is a software package which
runs on Windows (95/ 98/ 2000/ NT/ XP)

Interfaces computers to a number of
different oximeters

This presentation describes the main
features & applications and is intended for
the respiratory or sleep technician/ clinician
Features & Benefits

Many oximeters store data internally and this
trend data is accessible to computers

Download 2001 allows you to move this
recorded data from the oximeters to your
computer to View and Analyse it

This is extremely useful both clinically and
for research purposes
Dl2001 with Oximeter

The computer serial port (or USB port via a
serial port adapter +) is connected to the
oximeter output connector P1 + Contact SSI

The handheld oximeter is in its docking
station*, both turned on with the ASCII 2
output mode set
* RDS 1, 1B, 3 or 3B

The oximeter and computer are powered up
and the Dl2001 programme run on the
computer in Windows
Oximeter Link
A mouse click on
the oximeter icon on
the menu bar
creates the link with
the oximeter
Simple Method
If you choose:
- ‘Automatically
download largest
recording’ and
- ‘Auto print report
after downloading’
sit back and wait
for the report to be
printed!
* tick the boxes
Otherwise….
View the data - checking the quality as
it comes in to the computer

(1)
Otherwise….
(2)
Choose required
recording from oximeter
recordings

Assign the patient
name and details to it

The data screen
(‘chart’) will then open

First Data Screen

This screen shows 10 minutes of the recording
Two SpO2 low alarm violated vents are shown in red as well as the
actual alarm limit (90)

Downloading Data to Computer:
Preparing for Next Patient

Oximeters typically store 24 hours or even up
to 72 hours (several nights of data) of data

The software can handle this amount of data,
but it is quicker to clear the oximeters
memory after downloading to the computer

It is then ready for the next recording
Controls and Data Manipulation

View the full study by clicking on an icon, or
see a different time period on screen with the I
(interval) icon

Step (Page) through the data

Pan through the data page by page (adjust the
speed with View | Page | Pan Rate)

View numerical values by moving the cursor
on the trace
Full Study or Interval?
Full Study Icon
Interval Icon
Select study
range for
chart screen:
- ‘Full Study’
or
- ‘Interval’
Zoom
Zoom In Icon
Zoom Region Icon
Get more
detail with:
- ‘Zoom In
(binary x2)’
or
- ‘Zoom
Region’
Marking a ‘Zoom region’ 
Right hand side numbers
shown at vertical cursor:
- SpO2 value of 77
- pulse rate value of 61
Amplitude Control
Here the axis is being reset
to 70 - 100% Saturation
RH
Mouse
Menu

Fit To Scale (the trace) or
change the Amplitude
with the mouse right hand
button menu | Amplitude
control

Move and change the
amplitude using the
cursors - singularly or
together
Interval Control (The Ruler)

The Ruler allows you to control and see the
time interval marked between the cursors in
context of the recording (ie 3am - 4 am)

Cursors can be moved singularly or in
tandem by mouse - good for ‘nudging’
forward to see end of an event

The ‘Interval Icon’ can also be used to
change the interval in fixed steps
Analyse the Recording

Choose Analyse |
Analysis Report

Use Marked regions for
exclusion/inclusion of
chosen intervals

The other options (Plot
SpO2 etc) give single
pages from the report
Analysis Report - Page 1
Summary Page

Study & Patient
Details:
- Name
- Address
- Ht, Wt, Neck Size
- Epworth, BMI etc

Comments can
be entered from
the keyboard
Analysis Report - Page 2
Results
Overview
Analysis Report - Page 3
Saturation Plot

Plots:
- 1 hr/ line
- 8 hrs/ page

The vertical
axis is set in
Analysis |Setup |
Plot Options
Analysis Report - Page 4
Saturation
Analysis:
- mean, median, mode
- 5th/95th percentiles
- Dip rates x3 levels
(desauration events)
- Delta index, RRI & RDI
- minima,Time below
xx%
- frequency &
cumulative distributions
etc
Analysis Report - Page 4
Saturation Analysis
(extended):
- mean nadir
- Dip rates x6 levels
- Average and Maximum
event durations
- Saturation minima, etc
Analysis Report - Page 5
Pulse Rate Plot

Plots:
- 1 hr/ line
- 8 hrs/ page

Again, the
vertical axis
may be
changed in
Setup
Analysis Report - Page 6
Pulse Rate
Analysis:
- mean, median, mode
- standard deviation
- pulse rate rises
(PRR), PRR/hr
- Minima & Maxima
- frequency and
cumulative plots
etc.
Analysis Report - Page 7
Saturation & Pulse
Rate Plot

Plots:
- 1 hr/ line
- 8 hrs/ page

Dips, Pulse rate
rises are marked
Analysis Report - Page 8
All Channels
12 hr plot


6 hrs/ line
Vertical axis may
be changed in
Setup
Analysis Report - Page 9
All Channels
24 hr plot


12 hrs/ line
Vertical axis may
be changed in
Setup
After Analysis:
Chart showing detected events
Editing & Adding New Events (1)

Use Insert/ Edit events
to edit/ move/ delete/
add existing events
with the mouse

Use Display/ Edit event
definitions and Insert
Event to add new
events/ event types
Editing & Adding New Events (2)


Can choose to exclude data associated to
marked events
Defined events can be observed in the chart
screen, and name of event by moving cursor
over event
Access/Search for Recordings

Search by
surname/ ID

Display
recording date/
time/ duration

Display patient
summary
(yellow box)
Help

The context-sensitive HELP programme is
accessed by buttons in each dialogue box
(see next slide)

The manual in Adobe Acrobat .pdf format
and the Adobe Acrobat reader is included
on the installation CD

Email and telephone support is also
available from Stowood directly
Help File Example

This shows
the
description of
the Ruler in
the HELP file.
Advanced Features: Montages

The 5 Montages are presettable configurations
of axes, intervals, and presentations which
can be accessed by a single icon
Advanced Features:
Display Method

As longer data intervals are
squeezed onto the display,
it is essential to show them
without losing utility

For oximetry the best way
is to show the minimum
value, for Pulse rate it may
be best to have the
envelope
Advanced Features: Markers


Parts of single or both traces may be marked
and labelled with the mouse or using a dialogue
box
The Markers may be visible or hidden
Advanced Features: Grid

A grid in colours of your choice can be
superimposed over the data (use View | Show
Grid and Edit | Gridlines Colour)
Advanced Features:
Combine, Export & Printing

Combine separate recordings
made in series

Export the data in text or Excel
readable format

Dump patient details/ results in
text format

Print Chart and report to
standard Windows printers in
B&W or colour
Advanced Features:
SpO2 Analysis Setup


Set your preferred dip definition (x3)
and plot axes for the report
Select to display extended SpO2
analysis page
Advanced Features:
Pulse Rate Analysis Setup

Set your preferred Pulse peak definition
(x3) and plot axes for the report
Advanced Features:
Report Analysis Setup

Set up the information to be contained
in your preferred report
Advanced Features: Import

Importing ‘Actiwatch’ recordings (Cambridge
Neurotechnology) as another trace
Advanced Features: Details (1)

Patient, study details and comments can be
entered and exported
Advanced Features: Details (2)

Enter referring practice details
Advanced Features: Details (3)

16 configurable (with your labels) data entry
fields can have data entered, stored and
exported
Language Option

There is currently
an English
(Original) and
French version

German and
Spanish versions
under development
Applications

Download 2001 is typically used in adult or
paediatric overnight studies at home or in the
ward

It is used to determine the range of oxygen
saturations and pulse rate experienced by the
patient.

It can also be used in many other situations,
eg. with nCPAP to determine efficacy of
treatment and also in research
Technical Information: 1

Download 2001 runs on W 95/ 98/ NT/ 2000/
XP platforms with SVGA (800 x 600 and up)
displays

Computers should have a serial port or USBserial adapter

Connector cables are available from your
Masimo supplier or Stowood
Technical Information: 2

Installation on the computer is by:
- Installshield from the CD or
- floppy disks created from the CD

The method for desaturation dip detection is
described in Stradling & Crosby BMJ 1990
300 75-8
Technical Information: 3

Available now for:
- BCI 3303
- Datex- Ohmeda 3700/ 3740/ 3800/ 3900
- Minolta 3i/ 5/ 7/ 8
- Masimo Radical
- Nonin 2500 and 8500
- Novametrix 515/ 520 oximeters
- Radiometer TINA

Versions under develoment for:
- Criticare 504
- Certain Nellcor N200s
- BCI 3303/ 3304
- Other oximeters/CO2 monitors also under development
Availability

Download 2001 may be purchased from your
Masimo supplier

For further information and support, contact
us on +44 (0) 1865 35 8860 or email
[email protected]

Our websites are www.stowood.co.uk and
www.stowood.com
Shipping Details

Download 2001 includes:
- Installation CD with installation software
- Manual and Help file
- PowerpointTM presentation
- Cable for one oximeter type

Upgrades from Download for Windows (16bit
s/w) to Download 2001 are available

E&OE
The End
© Stowood Scientific Instruments
OX3 9UP, UK
www.stowood.com
Thanks for Watching!
Let us have your feedback: