Transcript V8プレ資料
Functions of “V8 series” are available, of course. Safety designing considered security and safety. The i-type (high-functionality) is equipped with Ethernet as a standard feature. Handheld V808CH Series debut! First edition: September 30, 200 Copyright 2008 2007 Hakko Electronics Co., Co.,Ltd. Ltd.All AllRights RightsReserved. Reserved. -0- Line-up 7.5” TFT VGA model V808iCH0 7.5” TFT 64K-color VGA TFT 64K Color Serial 2ch USB-B Ethernet V808CH0 FROM 4.5M 2M V808iCH1 Ethernet Deadman SRAM SW 128K Momentary FROM SRAM Deadman Key SW 12.5M 2M 512K Momentary Switch V808CH1 FROM 4.5M 2M Deadman Key SRAM SW 128K Momentary Switch V808iCH2 Ethernet FROM SRAM Deadman SW 12.5M 2M 512K 3-position*1 Deadman V808CH2 FROM 4.5M 2M SRAM SW 128K 3-position*1 V808iCH3 Ethernet FROM SRAM Deadman Key SW 12.5M 2M 512K 3-position*1 Switch V808CH3 FROM 4.5M 2M Deadman Key SRAM SW Switch 128K 3-position*1 V808iCH4 Ethernet FROM SRAM Deadman SW 12.5M 2M 512K 3-position*2 V808CH4 FROM 4.5M 2M SRAM SW 128K 3-position*2 CF I/F Emergency Stop SW FROM SRAM Deadman SW 12.5M 2M 512K Momentary Deadman *1 Output External 1, Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. *2 Output External 2 -1- Safety Feature Included the features that ensure the safety and security - Key Switch *1 A key switch is built-in so that only the person who has the key can operate the unit. - Dead-man Switch With a dead-man switch, you can prevent the false operation. Since three position types are available*2 vary from model to model, the output will be turned off even if you hold the switch tightly by unexpected accident. - Emergency Stop Switch Emergency stop switch in push lock method (galvanically separated mechanism) is included as standard equipment. Since an optional switch guard is also available, you can prevent the unconsidered emergency stop by using it. [When switch guard is mount *1 Available with only V808iCH1, V808CH1, V808iCH3, and V808CH3 *2 Available with only V808iCH2, V808CH2, V808iCH3,V808CH3, V808iCH4, and V808CH4 Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. -2- 8-way Comm. <Mixed Connection of Serial & Ethernet> Realizes the connection with PLC from up to eight different models or different manufacturers. 8-way communication realizes the connection with PLC or other automation devices from up to eight different models and/or different manufacturers by combining the connections of Ethernet (8-protocol) and serial (2-protocol). PLC from Co. APLC from Co. A PLC from Co. A Ethernet Connectable up to 31 units (LAN) RS-232C TB2 RS-422/485 Inverter TB3 PLC from Co. B Serial LAN Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. -3- USB port as Standard Equipment Slave (USB-B) Interface - Compatible with “PictBridge” printers PictBridge printers are now compatible. Documents such as a daily report and a monthly report can be printed out extremely easy. - High Speed Transfer of Screen Program Large capacity of the screen program designed by configuration software “V-SFT-5” can be transferred at high speed. Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. -4- LAN as Standard Equipment * 100BASE-TX/10BASE-T Interface - Screen program transfer Large capacity of screen program prepared by the configuration software “V-SFT-5” can be transferred at high speed. - Device Connection It is possible to connect plural PLC from different manufacturers with one V8 at the same time via Ethernet. - MES Interface Function Various kinds of information such as the production record, defect quantity, and error causes can be sent to the database in SQL statement via V-Server from V8. - When LAN is not in use. Mount a rubber cover when LAN is not in use - FTP Server Function It becomes possible to read and write each data from upper PC to Monitouch. Special application is not required because it transfers by general communication protocol. * Available only in i-type Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. -5- CF Card Interface as Standard Equipment Case 1 <Recipe Data> Production condition of each production item created in PC can be saved in CF card as CSV file. The saved data in CSV file can be read and written in PLC, and the data in PLC can be loaded in CF card at tooling change. Case 2 <Sampling> Ever-changing data and changes of the abnormal condition can be sampled and saved as records. Because you can save the data in CSV format, the file can be open in Excel without modification and also can be edited. Case 3 <Screen Program Transfer> Changed screen program is saved in CF card when performing the screen program change. Screen program can be transferred from CF card without carrying your PC to the production site. Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. -6- FROM & SRAM Loaded Available drastic increased FROM capacity & SRAM High-capacity FROM Screen memory capacity of FROM is drastically increased to 12.5MB (4.5MB with no i-type). It allows you to design the screen program without caring the memory capacity. V808iCH V608CH High-capacity SRAM 12.5MB *1 2.7MB Built-in SRAM 512KB (128KB with no i-type) is available as standard feature. Capacity for the sampling data and range of use of the user memory are drastically enlarged. *1 Available only in i-type Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. -7- Part Names - Equipped a wealth of interfaces USB-B TB1:Power supply(24V) CF card I/F Ethernet TB2:RS-232C and External output (4 points) TB3:RS-422/485, Key switch output, and Emergency stop switch output Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. -8- V808CH Exterior View (Unit: mm) - Side - Front - Rear - Bottom - Top surface Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. -9- Product Specifications *1 *1 Available only when SIEMENS MPI is connected. Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. -10- Configuration Specifications Model Remark Ethernet FROM SRAM V808iCH0 Yes 12.5MB 512KB V808CH0 N/A 4.5MB 128KB V808iCH1 Yes 12.5MB 512KB Dead-man switch Key switch Scheduled to acquire CE/UL/cUL N/A Scheduled to acquire CE/UL/cUL Momentary No external output With internal import Scheduled to acquire CE/UL/cUL Yes V808CH1 N/A 4.5MB 128KB Scheduled to acquire CE/UL/cUL V808iCH2 Yes 12.5MB 512KB Scheduled to acquire CE/UL/cUL V808CH2 N/A 4.5MB 128KB V808iCH3 Yes 12.5MB 512KB N/A Scheduled to acquire CE/UL/cUL 3-position External output 1-point With internal import Scheduled to acquire CE/UL/cUL Yes V808CH3 N/A 4.5MB 128KB V808iCH4 Yes 12.5MB 512KB V808CH4 N/A 4.5MB 128KB Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. Scheduled to acquire CE/UL/cUL 3-position External output 2-point Without internal import Scheduled to acquire CE/UL/cUL N/A Scheduled to acquire CE/UL/cUL -11- Accessories - Configuration Software V-SFT-5(Ver.5) Windows98/Me/NT Ver4.0/2000/ XP/XP 64 Edition/Vista 32bit Edition - Option Units V8H-Cx V8H-SWG UB-FR External-connection cable exclusively for V808CH. x: 3, 5, 15, 20m Switch guard to prevent the false operation of the emergency stop switch. Cable for USB-B board surface extraction V7-BT V6H-WF V8H-WFV Replacement lithium battery for V8 series. Set of bracket for wall hanging Fixing bracket exclusively for V808CH. V6H-WF1 Bracket for wall hanging (Wall side) Copyright 2008 Hakko Electronics Co., Ltd. All Rights Reserved. -12-