T775 Series 2000 Standalone Controller

Download Report

Transcript T775 Series 2000 Standalone Controller

SmartVFD HVAC and BYPASS Introduction

2

Smart Technology to Reduce Electricity Consumption

“Today, our continuing progress is restricted…not by the power of pumps, but by the depletion of aquifers.”

-

Paul Hawken Natural Capitalism

What Can We Do?

-

Generation

 Wind, Solar, Geothermal -

Transmission

 Smart Grid, local generation -

Efficiency

 Almost everything else including drives

Buildings use 40% of US Energy

Buildings use Massive Amounts of Energy

• •

• Buildings use 40% of US Energy 74% of electricity is consumed by commercial buildings

(source: US DOE, 2008 Building Energy Data Book)

More than half of that electricity is used to move air and water

3

Pumps & fans use more than half the world’s energy

Why Buy Drives:

VFDs Reduce Electricity Use

VFDs significantly reduce electrical consumption

-

Most pump and fan systems are oversized to account for maximum loads

-

Capacity usually exceeds demand Application of VFDs converts systems to variable flow

• •

Green House Gas Reduction

-

80% of commercial building CO 2 emission due to electricity consumption VFDs reduce Wear and Tear

-

Soft Start

4

A VFD provides speed control for a fixed-speed motor

Opportunities are Everywhere

Supply and return fans

Cooling Towers

Compressors

Stairway and parking ventilation

Boiler pumps and fans

Kitchen Hoods

Roof Top Units

Air Handlers

Elevators

Escalators

5

VFDs are a crucial part of energy management systems

What is a VFD?

• • Power Supply • 3 ~ • Variable Frequency Drive (VFD) • + • V1 • V3 • V5 • C • V2 • V4 • V6 • Rectifier • • DC- circuit • Inverter unit • Motor •

6

Energy Savings based on Proven Technology

7

Power Savings = Energy Savings

150 125 100 75 50 25 0 25 50 75 % Speed 100 125 150

Energy Savings

3/4 motor speed = 42% power

58% power saved

1/2 motor speed = 12.5% power

87.5% power saved Money Saved

Motor without VFD At 100% speed = $1,000 Cost Same motor with new VFD At 75% speed = $420 Cost

$580 Savings

At 50% speed = $125 Cost

$875 Savings

Whole Building Design

High performance HVAC Equipment - 10-40% energy savings

Whole-Building-Design - 40-70% energy savings - Design - Specify - Install and Commission - Maintain - Communication

8

Honeywell VFDs are crucial to energy management strategies

SmartVFD HVAC

• • • • •

Intuitive Interface Easy Commissioning Standard Communication Reliable Protection Effective Operation/Monitoring

9

The SmartVFD for Smart

Buildings

Graphic Interface

• • • • • • •

High resolution Intuitive commissioning Manual in keypad Help screens Real time clock Local/Remote Button Memory in keypad

10

Intuitive, Effective, Consistant SMART

11

Communications

Standard

RS485  BACnet  N2  Modbus Ethernet  Modbus/TCP  BACnet/IP -

Option Cards

 LonWorks  Profibus  CANopen  DeviceNet  Ethernet

Built-in Communications

Built-In Protection

DC Choke

Varnished boards

RFI filter standard

12

Harmonic, RFI, Environmental Protection

13

SMART Software

Start-up Wizard – Pump/Fan

Power loss ride through

Fire mode

Pump and Fan Cascade

Ramp Time Optimizer

Maintenance Counters

Pump Soft Fill

2 PID Controllers

The SmartVFD for Smart Buildings

14

SmartVFD BYPASS

• • • • •

Low total installed cost Compact size Easy component access NEMA 1, 12, 3R All configurations

Disconnect 2-contactor 3-contactor 3-contactor with AutoBypass, HOA Height Comparison 2ctr (1 - 7.5HP) 3ctr (1 - 7.5HP) 2ctr (10-20HP) 3ctr (10-20HP) 2ctr (20-40HP) 3ctr (20-40HP) Cool Blue 40 in 40 in 46 in 46 in 53 in 53 in Next Gen 30 in 37 in 33 in 40 in 43 in 53 in

Tools

• • • • • • •

SmartVFD Wizard Literature Energy Estimator Selection Tool Take-off Service Harmonic Simulator Technical Support

15

Specify-Select-Install-Operate-Monitor

16

http//.customer.honeywell.com/VFD

17

Value Proposition – SmartVFDs

• • •

For Contractors

• •

That need an easy to install, complete line of VFDs, cost effective, compatible with multiple communication protocols, strong warranty, technical support, high quality products Honeywell’s Variable Frequency Drives

Provide 1) low total installed cost; 2) complete line of drives and bypasses for all HVAC applications; 3) comparably priced throughout the VFD markets served; 4) compatibility with multiple communication protocols; 5)quality products backed by strong warranty and technical support

Unlike industrial manufacturers trying to push products in the HVAC segment and low-cost, low-quality manufacturers We do this by applying our building control expertise to a complete line of HVAC VFDs, easy interface for programming and commissioning (PC tools, programming wizards), offering standard communication capabilities (BACnet, ModBus, N2, LON), offering certification training, dedicated technical support and warranty peace of mind As demonstrated by past performance in year over year double-digit growth in the VFD portfolio.