SiD IR Layout

M. Breidenbach, P. Burrows, T. Markiewicz

SiD Collaboration Meeting 16-17 December 2005 Fermilab

2005.10.11 Discussion

2 / 13 • •

SiD Dimensions from 2005-05 files

– – – –

Barrel radius=6.450m

Barrel half-length=2.775m

EC Yoke=3.12m thick EC Yoke ends at 5.895m=2.775+3.120m

Garage assembly requirements

3m shielding wall between beamline position & garage

• Assuming self-shielding [which seems OK: see L. Keller, 2005.12.13 SLAC BDS mtg.] wall needed for commissioning only –

5m free space between shield wall & rotated barrel yoke3

• 2m free + 2m assembly fixture+1m free –

4m free space between rotated barrel yoke & rotated barrel HCAL

• 1m free + 2m assembly fixture+1m free –

5m free space between rotated barrel HCAL & pit wall

• 2m free + 2m assembly fixture+1m free

Tom Markiewicz

Detector Access Guesstimates

3 / 13 • • • • • • •

Door support leg overhang=

3.2m~25% door height (=barrel diameter=12.9m) Door opening=

3.0m

Free space to walk around door ends=

1.9m

Reserved radius =

8.0m (6.45 iron +1.55m services) Free space between dressed barrel & pit walls=

2.0m

PACMAN annulus=

3.0m [1m Fe, 2m concrete] Other

Tunnel diameter 3.2m

Assumed beam height=Barrel radius + 1m

Tom Markiewicz

SiD closed, on beamline, in 20m x 28m

10 8 6 4 2 -4 -6 0 -2 -8 -10 4 / 13 0 Barrel 2 Door Foot 3.0 m Mobile PAC1 Foot 4 6 Pit Wall 5.105 m Fixed PAC2 8 10 Shield Wall 12 14 Tunnel

0 -0.1

-0.2

-0.3

-0.4

-0.5

5 / 13 0 0.5

0.4

0.3

0.2

0.1

38cm OD Support Tube 2 40cm OD SiD Aperture 4 6

R20 Detail

Crab 8 10 12 1m wide platform 14 16

Tom Markiewicz

SiD open, on beamline, in 20m x 28m

-4 -6 0 -2 -8 -10 0 6 / 13 10 8 2 6 4 2.775 m 2 3.00 m 6.45 m 3.00 m 0.55 m 4 6 3.120 m 8 3.20 m 10 12 1.905 m 14 16

Tom Markiewicz

Half SiD in 48m x 28m IR anamorphic scale

10 5 -10 -15 -20 -25 0 0 -5 -30 -35 -40 7 / 13 2 4 6 Shield Wall HCAL rotated Barrel Yoke rotated 8 3.00 m 5.00 m 6.45 m 4.00 m 6.45 m 5.00 m 10 12 14 16

Tom Markiewicz

8 / 13

SiD (closed) in 48m x 28m IR x-scale=y-scale

Tom Markiewicz

Elevation View

Pit Elevation: 30m ?

– – –

1.000 Barrel-floor 12.90 Detector diameter 12.90 Free space above detector

3.000 Crane bridge and hook

9 / 13

Tom Markiewicz

Remaining Issues

• •

Door opening sequence

If 3.0m long PacMan moves over leg (how?) to outside

• 55cm clearance between door radius and PacMan seems marginal – On Shielding wall side, assuming shielding not needed after commissioning, infinite space available – On far side of garage, 10m is arbitrary » 12m is approximate maximum for 2 IR Baseline Configuration » Push-Pull not analyzed yet • Maybe move it out radially, then back (in z) to tunnel wall –

5.105m long PacMan either stays in position, surrounding final doublet/crab support platform, or itself opens radially to move to far walls, permitting 3.0m PacMan to open slightly & move back to pit wall Many beamline devices including Crab Cavity within 14m of IP

It would be very, very good to have these devices in the tunnel

Suggest we adopt a 18m wide hall by minimizing to ~ZERO both:

• 1.9m free space at end when door opens (SLD was ~0.5m) • 3.2m door support length – pocket in wall for door support legs – use legless scheme for earthquake proofing / moving 10 / 13

Tom Markiewicz

10 8 6 -8 -10 -4 -6 4 2 0 -2

Si D Open in a 20m x 18m Data Pit

Support Legs in pockets, screw drive earthquake constraints, etc.

2 4 6 8 10 Pit Wall at z=+9m 12 14

Half SiD in 48m x 18m IR Hall Anamorphic scale

10 5 0 -5 -10 0 -15 -20 -25 -30 -35 1 2 3 4 5 6 7 8 9 10

Tom Markiewicz

13 / 13

SiD (open) in 48m x 18m IR X scale = y scale

Tom Markiewicz