OCE 2006 Presentation Template

Download Report

Transcript OCE 2006 Presentation Template

3051SMV Transition
Blue Horizon
Emerson Confidential
Agenda

Transition to the 3051SMV: 3095M-HART Discontinuance
– 3095M-HART Final Order Date
– Models Affected

3051SMV Feature Improvements
– 3095M-HART Comparison
– Flowmeter Offering
– Engineering Assistant Support

Summary
Blue Horizon
Emerson Confidential
2
Transition to the 3051SMV from the 3095M-HART

Since the release of the 3051SMV in Oct. 2009, market
led transition was expected
– 3051SMV has higher performance and more features
40% of customers
already transitioned

Transition time-frame shortened by Japanese crisis
–
–
–
–
Earthquake and resulting tsunami destroyed a supplier’s factory
Supplier has decided to discontinue the component
Timeframe to redesign unacceptable
No other 3095 or Rosemount products are affected
Blue Horizon
Emerson Confidential
3
3095M-HART Final Order Date

Final Order Date:
July 29, 2011


Orders will ship at standard lead-times
Service and warranty requests will be honored with
remaining 3095M-HART inventory or an upgrade to
3051SMV
– Option to upgrade at the cost to repair a 3095M through for two
years or five years from the original shipment date of device,
whichever comes first
Blue Horizon
Emerson Confidential
4
3095M-HART Models To Be Transitioned

3095MA HART Transmitters
– 3095MAxxxxxxxxxxxxx…
– NOT Affected:
• 3095MV FOUNDATION fieldbus
• 3095FB MODBUS

3095MFx HART Flowmeters
–
–
–
–
3095MA HART
3095MFAxxxxxxxxxxxxxxxxxAxx...
3095MFCxxxxxxxxxxxxxAxx…
3095MFPxxxxxxxxxxxxxxxAxx…
NOT Affected:
• 3095MFx FOUNDATION fieldbus
Flowmeters
3095MFP
Blue Horizon
Emerson Confidential
3095MFA
3095MFC
5
Rosemount 3051S MultiVariable
HART Transmitter
Joule Thomson Correction Terminal block temperature wiring
COLD
Energy and Mass or
Actual Volumetric Flow
Patmosphere
Tspray
Pcan
Tcan
Because Pcan > Patmosphere
Then Tcan ≠ Tspray
User specified temperature limits
and temperature backup
Accurate Flow Measurement Requires
Dynamic Compensation
% Reading
10
9
8
7
6
5
4
3
2
1
0
DP DP
P P
T T T T
User-specified
Time
Early Detection
Temperature
sensor limit
DP
P
T
Sensor Matching with
Callendar-van Dusen
±0.1% Span
3051C
3051S Ultra
Ultra for Flow
10:1 5:1 3:1 2:1 1:1
Backup temperature
or alarm enabled
Easy 2 Step
Configuration
Ultra For Flow
Flow Turndown
Blue Horizon
Emerson Confidential
User-specified
Fixed (Hard Limit)
Qmass  NCDY1Ed 2 DP 
Coefficients vary
with all three
measurements
Fixed (Hard Limit)
Temperature
Real-time compensation of over 25
variables @ 22 updates/second
RTD Sensor Accuracy
Standard RTD Sensor
2 ºC (3.6 ºF)
1 ºC (1.8 ºF)
Gas, Natural Gas
and All Steam
RTD with Sensor Matching
0 ºC (0 ºF)
Saturated Steam
Liquids and
Saturated Steam
1. Differential Pressure
2. Pressure
3. Temperature
Liquids
o
o
o
o
o
Scalable
Compensation
-1 ºC (-1.8 ºF)
-2 ºC (-3.6 ºF)
0 ºC (32 ºF)
200 ºC (392 ºF )
400 ºC (752 ºF)
1. Differential Pressure
2. Pressure
o
o
o
1. Differential Pressure
2. Temperature
1. Differential Pressure
6
Integrated Flowmeters Available With
the 3051SMV
3051SFP
3051SFA
3051SFC
3051SFx Flowmeters Offer Equivalent 3095MFx Features
– Fully Assembled, Configure, Leak Tested
– Annubar, Compact Orifice, and Integral Orifice
– Integral Temperature option
Blue Horizon
Emerson Confidential
7
Transitioning to the Rosemount 3051SMV
Improves Flow Measurement
Rosemount
3051SMV
Rosemount
3095M-HART
Ultra for Flow: ±0.65%
U3: ±1.0% of Rate
Mass or Energy
Rate over 14:1
over 10:1
Flow Reference Classic MV: ±0.70% Rate Std.: ±1.0% of Rate
Accuracy
over 8:1
over 8:1
3051SMV: Superior Flow Measurement
Totalized Mass
Flow Accuracy
±0.65% of Total Mass or
Energy Flow
±1.0% of Total Mass
Flow
DP: 200:1
AP: 200:1
DP: 100:1
AP: 100:1
Ultra and Ultra for Flow:
12 years
Classic: 12-18 months
U3: 12 years
Standard: 12-18
months
Update Rate
22 updates / second
2.5 updates / second
Energy flow
Calculation
Natural gas and Steam
Not Available
Scalable
Measurement
Solutions
All combinations of DP,
P, T
DP+P+T or
DP+P (Fixed T)
• Improved Mass and Energy Flow Calculations
•Scalable Measurement Options for Liquids and
Rangeability
Saturated Steam
• Easy Start-up and Simplified Maintenance with
Warranty
Engineering Assistant 6.1.1
Blue Horizon
Emerson Confidential
8
3051SMV vs. 3095M-HART
Physical Comparison
3051SMV

Coplanar
Connection

Height: 8.53-in.
(217 mm)
3095M-HART


Coplanar
Connection
Height: 7.07-in.
(180 mm)
– 1.46-in. (37 mm) taller

Weight: 6.7 lbs (3.0 kg)

Weight: 6.0 lbs (2.7 kg)

Temperature Connection
– 0.7lb (0.3 kg) heavier

Temperature Connection
– Terminal Block
Blue Horizon
Emerson Confidential
– Temperature Boss
9
3051SMV vs. 3095M-HART
Dimensional Comparison
3051SMV
A
B
C
D
Blue Horizon
Emerson Confidential
3095M-HART
Measurement
3051SMV
3095MA
Overall Height
Width of Transmitter, without
LCD Display
Width of Transmitter, with LCD
Display
Process Connection Center-toCenter
8.53 (217)
4.55 (116)
7.07 (180)
4.3 (110)
5.21 (132)
5.00 (127)
2.1 (54)
2.1 (54)
10
Engineering Assistant Support




EA 6.1.1
EA 5.5.1
 For 3051SMV
 For 3095M
 Stand alone
 Stand alone
powered by AMS
AMS SNAP-ON planned
 AMS SNAP-ON
Full listing of fluids
 Full listing of primary
Most primaries supported
elements and fluids
Ongoing maintenance
 Available to support
releases for new
legacy installations
capabilities
Both versions will continue
to be available
Blue Horizon
Emerson Confidential
11
Start Your Transition to the 3051SMV
Transmitter and Flowmeters Today

REMEMBER: Last Order Date for 3095M-HART
– July 29, 2011

3051SMV Offers Equivalent 3095M-HART Features and
More:
– Superior Flow Measurement Performance
– Improved Temperature Measurement
– Fully Integrated Flowmeters
3051SFC
3051SFP
Blue Horizon
Emerson Confidential
3051SFA
12
13