Transcript CaseStudy

Electrodeless Induction Lamps
Tunnel Lighting
Application
LeuchTek GmbH
www.LeuchTek.de
Wendenstrasse 279,
D-20537 Hamburg
V0.1
Electrodeless Induction Lamp

Ultra-long Lifetime, 60000-100000hours, 5 years guarantee

Energy-saving (70-90lm/w) and less maintenance cost

CRI>80, objects can be seen clearly, less traffice accidents

Instant Ignition & Restrike, suitable for emergency lighting

Environment Protection
LeuchTek GmbH www.LeuchTek.de
Products for Tunnel Application
IT-1 series
IT-2 series
- Power: 80W-200W
- Aluminium case, IP65,
- size: 700x333x193
- Ballast is inside the main case
- Power: 200W-400W
- Aluminum case, IP66
- size: 1220 x 370 x 310
- Ballast is out of the main case
Additional:
- Emergency lighting is possible, DC24V running for two hours with 50% lamp watt dimming
during power off.
- Intelligent control system(dimming and switch on/off) based on Dali-bus is possible
LeuchTek GmbH www.LeuchTek.de
Application Study
LeuchTek GmbH www.LeuchTek.de
Higher Lumen, then higher lux??
Not definitly!
Induction lamp has 70-90lm/w which is not the higest, however:
Normal lamp is point-light or line-light source,
efficiency is more reliable from a reflector. Induction
lamp is surface-lighting source, which has much
bigger luminous surface and better uniformity.
The measured result of a normal Lux-meter is
„photopic lumen“, which is not really corresponding
the sensitivity of humen eyes. More scientifically,
„scotopic lumen“- pupil lumen (Plm) should be
measured for comparasion.
HPS Lamp is 90Plm/W, induction lamp is 140Plm/W
LeuchTek GmbH www.LeuchTek.de
555nm
150W Induction lamp VS. 250W MH
Items
Induction Lamp
Metal Halide
Consumption Power
150W(total 160W)
250W (Total 280W)
Lamp quantity
Installation height(m)
Distance between(m)
Eave(Lux)
U1(Emin/Eave)
measured area(m2)
Total area(m2)
Power per m2(W/m2)
154 sets
7
4
360
0.94
12
2304
160×154/2304=10.69
154 sets
7
4
388
0.82
12
2304
280×154/2304=18.72
Single lamp lumen(lm)
Total lumen (lm)
12000
12000×154=1848000
20500
20500×154=3157000
Measured lumen(lm)
360×2304=829440
388×2304=893952
Utilized Index(UI)
829440/1848000=
44.9%
893952/3157000=
28.3%
LeuchTek GmbH www.LeuchTek.de
Cost comparasion in 60000 hours
Item
150W induction lamp
(Total 160W)
250 HPS lamp
( Total 280W)
Power consumption
(0,12EUR/KW)
0,16 x 60000 x 0,12EUR
= 1152,-EUR
0,28 x 60000 x 0,12EUR
= 2016,-EUR
Bulb cost
0 EUR
6 x 28,-EUR = 168,-EUR
Bulb change labor
cost
0 EUR
6 x 20,-EUR = 120,- EUR
Cost to partly block
the tunnel for
maintenance
0 EUR
??
Total Cost
1152,-EUR
> 2340,-EUR
Saved cost per lamp
> >1188,-EUR
LeuchTek GmbH www.LeuchTek.de
Reference Project 1
Highway Tunnel, emergency lighting
100W Induction
Emergency
lighting
Normal power:
100W
Emergency with battery: 35W
Lamp Distance:
35m
Height:
5.3m
Average lux:
46LX
LeuchTek GmbH www.LeuchTek.de
100W HPS
Reference Project 2
Highway tunnel in Yunnang
Entrance: 1354LX
Transition 1:381LX
Transition 2:267LX
Main :
58LX
Exit:
252LX
LeuchTek GmbH www.LeuchTek.de
Reference Project 3
•
Tunnel in Korea
Induction Lamp:Bright、Modern、Good CRI
Before Installation: 250W HPS
Sodium Lamp:Dark、Old、Bad CRI
After Installation: 120W Induction Lamp
Illuminance:403 lux
LeuchTek GmbH www.LeuchTek.de
Reference Project 4
• Infrastructure Applications– Tunnel #2 in Kunan Expressway in China
300W 504 units, 150W 440 units
LeuchTek GmbH www.LeuchTek.de
Reference Project 5
• Infrastructure Applications-- Underground Walkway in Korea
LeuchTek GmbH www.LeuchTek.de
Thank You
LeuchTek GmbH www.LeuchTek.de