Rev1.0 04 Mar., 2013
Over view
Database Converter (NS1000 Off line mode V2.0)
Over view 1/3
The off-line programming tool provides legacy database converter feature
that can convert system data of NCP/TDE/TDA series PBX
into data for NS1000.
Off line tool (V2.0)
UPCMC (PBX Replacement)
TDE100 DMSYS
/200
TDE600 DGSYS
TDA100
/200
DSYS
TDA600
DLSYS
NS1000 is overwritten
in new DCSYS.
Convert
Edit
DCSYS
report
NCP500 DBSYS
/1000
NS1000
Activation key is not transferred at the
converting database
TDA
TDE/NCP
The data of TDA should convert it into the data of TDE in
UPCMC. Then it can be used for conversion into the
data of NS1000.
3
Database Converter (NS1000 Off line mode V2.0)
Over view 2/3
The feature supports 2 functionalities as follows.
1) Platform Replacement (TDE/NCP->NS1000)
Legacy database converter for replacing to NS1000 from legacy PBX
The target data of convert is the data of only IP Trunk and IP terminal.
The data of a physical IP-GW card is not converted.
IP Trunk
IP Trunk
V-IPGW16,V-SIPGW16
IP-GW4,16 It’s not supported.
V-IPGW16,V-SIPGW16
TDA/TDE/NCP
NS1000
TDA/TDE/NCP
not used
IP terminal
IP terminal
V-IPEXT32
V-SIPEXT32
V-IPCS4
IP-EXT16 (Physical card)
V-IPEXT32
V-SIPEXT32
V-IPCS4
4
Database Converter (NS1000 Off line mode V2.0)
Over view 3/3
2) Platform As Legacy GW Data (TDE/NCP->NS1000+Legacy GW)
Legacy database converter for using existing PBX as legacy gateway.
Of course, data related to IP is converted like case “1) Platform Replacement”.
IP Trunk
IP Trunk
V-IPGW16,V-SIPGW16
IP-GW4,16 It’s not supported.
V-IPGW16,V-SIPGW16
STACK-M
Legacy Trunk
Legacy Trunk
TDA/TDE/NCP
DPT/SLT
IP terminal
V-IPEXT32
V-SIPEXT32
V-IPCS4
IP-EXT16 (Physical card)
STACK-S
DPT/SLT
PS can be used
without
re-registration.
IP terminal
V-IPEXT32
V-SIPEXT32
V-IPCS4
5
Condition
Database Converter (NS1000 Off line mode V2.0)
Condition 1/7
The database converter is a part of application in off-line programming software
and it is initiated by clicking the icon on launcher of the off-line programming.
Note: Not support to convert via Web-MC (On-line)
The following table shows target series of PBX and the version number
to be converted.
Series of PBX
Version number
NCP500/1000
Ver. 6
TDA100/200
Ver. 5
TDE100/200
Ver. 6
TDA600/620
Ver. 5
TDE600/620
Ver. 6
Remark
*1
*1
*1: Database file has to be converted into DGSYS or DMSYS of KX-TDE by using
data replacement application on PCMC before the legacy database convertor.
7
Database Converter (NS1000 Off line mode V2.0)
Condition 2/7
Mode: Platform Replacement (TDE/NCP->NS1000)
The following table shows which programming items can be converted
Programming items
Originated PBX
Extension *1,*2
Trunk
*3,*4
Numbering
Plan
COS
DDI/
DID
Group
SSD
PSD
CTI
NCP500/1000
TDE100/200/600
IP Extension
PS/IP-CS
IP Trunk
Yes
Yes
Yes
Yes
Yes
Yes
Yes
TDA100/200/600
IP Ext. of IP-EXT
card
-
Yes
Yes
Yes
Yes
Yes
Yes
Yes
*1: Include Extension number, Extension name, FF key data
*2: Only support IP Extension and PS/IP-PS
*3: Include Trunk number
*4: IP trunk of IP-GW card is not supported.
8
Database Converter (NS1000 Off line mode V2.0)
Condition 3/7
Mode: Platform As Legacy GW Data (TDE/NCP->NS1000+Legacy GW)
Programming Items
Originated PBX
Convert to
Extension
*1
Trunk
*2
Numbering
Plan
COS
DDI/
DID
Group
SSD
PSD
CTI
NCP500/1000
TDE100/200
TDA100/200
Legacy
GW1
All Ext.
All
Trunk
Yes
Yes
Yes
Yes
Yes
Yes
Yes
TDE600/TDA600
(Basic shelf)
Legacy
GW1
All Ext..
All
Trunk
Yes
Yes
Yes
Yes
Yes
Yes
Yes
TDE600/620
TDA600/620
(Basic shelf &
Expansion shelf 1)
Legacy
GW1+GW2
+GW3+GW4
All Ext.
All
Trunk
Yes
Yes
Yes
Yes
Yes
Yes
Yes
*1: Include Extension number, Extension name, FF key data
*2: Include Trunk number
9
Database Converter (NS1000 Off line mode V2.0)
Condition 4/7
Available converting patterns
pattern 1 (Replacement :Only IP)
NS1000
TDA/TDE/NCP
pattern 2 (Included Legacy)
NS1000
TDA/TDE/NCP
TDA/TDE/NCP
Legacy
GW1
Please connect existing
PBX with Legacy GW1.
pattern 3
NS1000
TDE620
TDE600
Shelf 2
Shelf 1
Legacy
GW2
Legacy
GW1
TDE600
TDE620
Shelf 1
Converting database of
TDE/TDA multi cabinet to
legacy gateway units.
TDE600
TDE620
Shelf 2
10
Database Converter (NS1000 Off line mode V2.0)
Condition 5/7
Available converting patterns
pattern 4
Converting database of TDE/TDA
multi cabinet to legacy gateway
units on NS1000 slave units.
Shelf 4
TDA620
TDA620
TDE620
TDE600
One Look Networking
Master
Slave
NS1000
NS1000
Legacy
GW1
Legacy
GW2
Legacy
GW1
Legacy
GW2
Shelf 3
Shelf 2
Shelf 1
Shelf 1
Shelf 2
Shelf 3
Shelf 4
The shelf location is fixed.
11
Database Converter (NS1000 Off line mode V2.0)
Condition 6/7
Unavailable converting patterns
pattern 1
Master
TDA/TDE/NCP
NS1000
Legacy
GW1
TDA/TDE/NCP
TDA/TDE/NCP
Legacy
GW2
TDA/TDE/NCP
Multi system
One Look Networking
Master
Slave
This tool doesn't support
data conversion of the multi
system.
NS1000
NS1000
Legacy
GW1
Legacy
GW1
TDA/TDE/NCP
TDA/TDE/NCP
12
Database Converter (NS1000 Off line mode V2.0)
Condition 7/7
Unavailable converting patterns
pattern 2
One Look Networking
Master
Slave
NS1000
NS1000
Legacy
GW1
TDA/TDE/NCP
TDA/TDE/NCP
This tool doesn't support the data conversion connected with the slave.
pattern 3
NS1000
TDA/TDE/NCP
Legacy
GW2
TDA/TDE/NCP
This tool doesn't support the data conversion connected with the Legacy GW2.
13
Database Converter (NS1000 Off line mode V2.0)
Table of item not converted 1/3
The converted value is indicated in right column
Function
Value (after the converted)
Time Service Switching Mode
The default setting
Time Setting (Time Table)
Clear
Timed Reminder
Clear
Extension Dial Lock
Unlock
Remote Extension Dial Lock
Unlock
Call Charge data
Clear
Not Ready (Manual Wrap-up) Mode On / Off
Off
LCS On/Off
Off
Hospitality Features
(Check In/Out Not Ready/Cleaned Up)
Clear
Auto Answer
The default setting
14
Database Converter (NS1000 Off line mode V2.0)
Table of item not converted 2/3
Function
Value (after the converted)
Absent Message
The default setting
Last Number Redial
Clear
Changing the Log-in/Log-out Status of
Extensions
Clear
Message Waiting
Clear
Incoming Call Log
Clear
Call Charge
Clear
Outgoing Call Log
Clear
TAM Log
Clear
OGM
Clear
Call Forwarding (FWD)/
Do Not Disturb (DND) Settings
Off
Traffic data
Clear
15
Database Converter (NS1000 Off line mode V2.0)
Table of item not converted 3/3
Function
Value (after the converted)
Verification Code PIN Lock state
Unlock
Verification Code PIN Lock counter
Clear
Password Lock counter for Remote System Clear
Programming
Major/Minor alarms
Clear
Error Log
Clear
Wake-up Call
Clear
16
Database Converter (NS1000 Off line mode V2.0)
Unavailable cards 1/1
Following components can not be used with Legacy-GW.
These data is deleted.
Symbol
Model
Description
RMT
TDA0196
Analogue Modem for Remote Maintenance
MEC
TDA0105/TDE0105
Memory Expansion Card
DSP4/16/64
NCP1104/TDE0110/TDE0111
VoIP channel card 4ch/16ch/64ch
CTI-LINK
TDA0410
CTI Link Card
IP-EXT16 *1
TDA0470
16-Channnel VoIP Extension Card
IP GW4/IP-GW4E
TDA0480/TDA0484
4-Channnel VoIP Gateway Card
IP-GW16
TDA0490
16-Channnel VoIP Gateway Card
MSG4
TDA0191
4-Channel Message Card
ESVM2/4
TDA0192/TDA0194
2/4-Channel Simplified Voice Message Card
CLCOT8 *1
TDA1180
8-Port Analogue Trunk Base Card w/ Caller ID
CLCOT8E *1
TDA1186
8-Port Analogue Trunk Daughter Card w/ Caller ID
MCSLC24
TDA1178
24-Port Single Line Telephone Card
MCSLC16
TDA1176
16-Port Single Line Telephone Card
*1: The data of IP extension is taken over to a virtual extension card.
17
Database Converter (NS1000 Off line mode V2.0)
Note 1/1
- TDA Database (DSYS and DLSYS) file has to be converted
into DGSYS or DMSYS of KX-TDE by using data replacement application
on PCMC before the legacy database convertor.
-New program items added in NS1000 are filled by the default value.
-All data of numbering plan are switched to originated (New DCSYS) data since
the default values are different between NS1000 and other PBXs.
-New setting of dial plan added in NS1000, which is not in legacy PBXs, are
filled with BLANK.
-OPB card and any card on OPB card are not supported to convert.
-Activation key is not transferred at the converting database.
18
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 1/7
Convert
NS1000 Off line V2.0
Converter type needs to be selected
from the following 2 types at initiation
of converter application.
1) Replacement
2) Legacy Gateway
After this selection, some of
mandatory system setting need to be
programmed, then DCSYS file for
NS1000 is created automatically.
DMSYS
or
DGSYS
or
DBSYS
19
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 2/7
It depends on data before it converts it
then the composition chart is shown.
For TDA/E600, and TDA/E620
when the slave is connected
For NCP, TDA/E100, and TDA/E200
20
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 3/7
A part of region should change
the setting. Please refer to P26.
Parametes and operation is completely
same as Easy Setup wizard.
P22
(When the slave is connected)
IP addresses,
type of registration and password, etc
programmed on TDE/NCP are displayed
by default.
Converting time is estimated to take with in 10
seconds
P23
(Case with TDE100/200/NCP)
21
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 4/7
This operation is required in case source
database file contains an more than 3
expansion unit setting of TDA/E600/620.
Converting time is estimated to take with in 10
seconds
P23
22
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 5/7
When the conversion of data
is completed, the report of the
result is displayed.
Example
Following Recommended A.K
Deleted Card
Activation key is not
transferred at the converting
database
23
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 6/7
The following three steps can be selected.
DCSYS
The name is given to the new data. (DCSYS)
Finish
And, converted DCSYS is downloaded.
Open Offline mode
Connection Online Mode
24
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 7/7
Please transfer (Installation) the “converted DCSYS” on Online mode.
C:\Documents- - - -DCSYS
The reset operation is necessary.
25
Database Converter (NS1000 Off line mode V2.0)
Suffix Code 1/1
Please change the setting to the area shown in the following tables.
Legacy gateway
NS1000
Suffix code
Area
Suffix code
Area
NE
CE
NE
CE
Eastern Europe
TR
Turkey
BX
Other
TW
Taiwan
RU
RU
Russia
UC
UC
Ukraine
BX
RU
BX
RU
BX
Note
In area other than this table, the change is unnecessary.
26
Database Converter (NS1000 Off line mode V2.0)
Result of Converting 1/2
The following results are displayed when data conversion is completed.
It might be effective help to make the New Configuration of NS1000.
These contents are examples.
Report of conversion result
(examples)
Complete of Database conversion
Original file : PSN_TDE600
Original PBX : TDE600
Following Recommended A.K.
One-look Networking
Up to 100 IP Phone Capacity
Deleted Card
Shelf1,Slot01 : IP-EXT16
Recommended AK is displayed.
Deleted Extension
6780, 6781, 6782, 6783, 6784, 6785, 6786, 6787,
16788,16789,16790,16791, 792, 793, 794, 795
Shelf1,Slot02 : IP-GW16
Deleted CO line
007,008,009,010,011,012,013,014,
015,016,017,018,019,020,021,022
Shelf1,Slot01-01 : OPB3 - MSG4
Both the deleted extension number and
the deleted CO number are described.
OPB card and any card on OPB card
are not supported to convert.
27
Database Converter (NS1000 Off line mode V2.0)
Result of Converting 2/2
Report of conversion result
(examples)
Deleted Card
Shelf4,Slot15 : MCSLC16
Deleted Extension
10001,10002,10003,10004,10005,10006,10007,10008,
10009,10010,10011,10012,10013,10014,10015,10016
Deleted Remote Access Device
599 : MODEM
699 : ISDN Remote
Change
IP-EXT16 : Shelf1,Slot01 -> V-IPEXT32 : Site01,Slot47
IP-EXT16 : Shelf2,Slot01 -> V-IPEXT32 : Site01,Slot47
Two IP-EXT16 cards were integrated
into one V-IPEXT32 card.
IP-EXT16 : Shelf4,Slot01 -> V-IPEXT32 : Site02,Slot47
Change SVM-Voice Msg Extension No. to UM channel No.
591 : SVM-Voice Msg1
-> 5101 : Master UM channel 1
592 : SVM-Voice Msg2
-> 5102 : Master UM channel 2
New Assigned
5103 : Master FAX Extension number
28
END
29
Appendix
30
Database Converter (NS1000 Off line mode V2.0)
Appendix : Supported PBX model
Application model (1/1)
KX-NS1000 allows connecting following system for legacy gateway system.
It means “The data of the application model is convertible “.
Legacy Platform's
TDA
TDE
NCP
Models
Yes/No
15
No
30/50
No
100/200
Yes
600/620
Yes
100D
No
100/200
Yes
600/620
Yes
500/1000
Yes
500 express
Yes
31
Database Converter (NS1000 Off line mode V2.0)
Appendix : Change of version of DSYS from V4 to V6
Change of version of DSYS (1/1)
Please use version 6 or late of UPCMC.
Example
V4
DGSYS
DGSYS
V6
32
Database Converter (NS1000 Off line mode V2.0)
Appendix : Suffix Table
Suffix Code and Area table. (1/2)
Suffix code
Area
Suffix code
Area
NE
NE
G
BL
NE
NE
G
BL
Germany. Austria
Belgium/Luxembourg
NE
DK
NE
DK
Denmark
NE
NE
FI
FR
NE
NE
FI
FR
Finland
France
NE
JT
NE
JT
Italy
NE
NL
NE
NL
Netherlands
NE
NO
NE
NO
Norway
NE
PT
NE
PT
Portugal
NE
SP
NE
SP
Spain
NE
SE
NE
SE
Sweden
NE
SL
NE
SL
Switzerland
NE
CE
NE
CE
Eastern Europe
NE
CE
NE
TR
Turkey
E
E
UK
UK
UK
GR
GR
NE
GR
Greece
AL
AL
AL
AL
Australia
NZ
NZ
AL
NZ
New Zealand
Note
Please select the
Area on the
converter.
33
Database Converter (NS1000 Off line mode V2.0)
Appendix : Suffix Table
Suffix Code and Area table. (2/2)
Suffix code
Area
Suffix code
Area
HK
ML
HK
ML
XE
XE
HK
ML
Hong Kong
Malaysia
SN
SN
XE
SN
Singapore
CN
M
CN
M
BX
M
BX
M
Others
USA
BX
BX
BX
BX
Other
BX
BX
BX
TW
Taiwan
BX
BX
BX
BX
BX
BX
SA
BX
SA
South Africa
AG
AG
AG
AG
Argentina
C
C
C
C
CE
CE
NE
CE
Eastern Europe
RU
RU
RU
RU
Russia
RU
RU
UC
UC
Ukraine
BR
BR
BR
BR
Brazil
Note
Please select the
Area on the
converter.
Canada