38-40MF Product Overview

Download Report

Transcript 38-40MF Product Overview

Cooling Only
Heat Pump
38MFC/ 40MFC
38MFQ/ 40MFQ
UTC Building Industrial Systems
PROPRIETARY and CONFIDENTIAL
PRODUCT OVERVIEW
High Wall
Cooling Only
Heat Pump
38MFC/ 40MFC
38MFQ/ 40MFQ
15 SEER
Line lengths up to 65’
Inverter Driven Compressor
Rotary compressor
3 indoor unit fan speeds
Turbo mode
Motorized louver allows fixed or oscillating motion
Indoor sound: as low as 34 decibels
Cleanable filters
CONTROL STANDARD FEATURES
Wireless remote control standard Turbo button
Optional wired remote Control
Wired remote controller
Wireless remote controller
2
UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution
MF SERIES HIGH-WALL FEATURES
Comfort:
Quiet operation
Auto changeover on heat pumps
Auto Swing
Air direction
Cold blow prevention on Heat Pump
Turbo fan mode
Wireless remote
Manual mode for emergency operation
Auto restart
Dry mode
3
UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution
MF SERIES HIGH-WALL FEATURES
Installation Flexibility/Ease Of Service:
Mounting brackets for indoor unit
Long lines application
Max outdoor ambient of 115°F in cooling
Operates down to 14°F
Condensate pump accessory
Test mode
On board and on unit diagnostic LED lights
Reliability
3 minute time delay
Over current protection on compressor
Indoor coil freeze protection
Condenser high temperature protection on HP & AC
Indoor evaporator high temperature protection on HP
4
UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution
System
Size
Outdoor Model
Indoor Model
Performance
SPECS COOLING ONLY (MFC SERIES)
Cooling Rated Capacity Btu/h
Cooling Cap. Range Min - Max Btu/h
9
38MFC009---1
40MFC009---1
12
38MFC012---1
40MFC012---1
12,000
18,000
22,000
4,000-10,000
4,500-13,000
5,500-19,000
6,500-24,000
8.5
10
SEER
EER
Wireless (°C, °F, Convertible)
Wired (°C, °F, Convertible)
Operating Cooling Outdoor DB Min - Max °F
Range Cooling Indoor DB Min -Max °F
Total Piping Length ft.
Piping Lift ft. *
Pipe Connection Size - Liquid (In)
Pipe Connection Size - Suction (In)
Voltage
Power Supply
Outdoor - MCA
Outdoor - Fuse Rating (MOCP)
Dimensions (W X H X D) In (net)
Outdoor Net Weight (lbs.)
Sound Pressure dBa
Dimensions (W X H X D) In (net)
Net Weight (lbs.)
Number of Fan Speeds
Airflow (lowest to highest) CFM
Sound Pressure dBa ( L / M / H)
15
10
9
9
Standard - Convertible
Optional: KSACN0101CAC
14 - 115
63-90
65
Piping
Electrical
22
38MFC024---3
40MFC024---3
9,000
Controls
Indoor
38MFC012---3
40MFC012---3
18
38MFC018---3
40MFC018---3
25
98
30
1/4
3/8
1/2
3/8
5/8
115 -1 -60
208-230-1-60
Indoor unit powered from outdoor unit
19
19
10
14
16
30
30
15
20
25
29.9 x 23.2 x 11.2 33.3 x 27.6 x 12.6
30.7 x 21.2 x 9.8
58.4
61.7
76.0
98.1
57
58
60
61
26.8 x 10.0 x 7.0
30.3 x 10.0 x 7.4
35.6 x 10.8 x 7.8 40.6 x 12.4 x 8.6
15.4
16.5
19.8
26.4
4
131/160/192/215 158/194/230/240 157/193/232/240 236/294/348/395 368/458/547/580
43/39/34
44/40/36
45/41/37
50/46/42
5
UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution
System
SPECS HEAT PUMP (MFQ SERIES)
Indoor
Electrical
Piping
Performance
Size
9
12
17
22
Outdoor Model
38MFQ009---1
38MFQ012---1
38MFQ012---3
38MFQ017---3
38MFQ024---3
Indoor Model
40MFQ009---1
40MFQ012---1
40MFQ012---3
40MFQ017---3
40MFQ024---3
Cooling Rated Capacity Btu/h
9,000
12,000
17,000
22,000
Cooling Cap. Range Min - Max Btu/h
4,000-10,000
4,500-13,000
5,500-19,000
6,500-24,000
SEER
15
EER
10.5
9.5
9.5
9
9.5
Heating Rated Capacity Btu/h
9,000
12,000
12,000
18,000
22,000
Heating Cap. Range Min - Max Btu/h 4,000-10,500
4,500-13,000
4,500-13,000
5,500-19,500
6,500-24,500
HSPF
8.2
Wireless (°C, °F, Convertible)
Standard - Convertible
Controls
Wired (°C, °F, Convertible)
Optional: KSACN0101CAC
Cooling Outdoor DB Min - Max °F
14-115
5 - 75
Operating Heating Outdoor DB Min - Max °F
Range Cooling Indoor DB Min -Max °F
63-90
Heating Indoor DB Min -Max °F
32-86
Total Piping Length ft.
65
98
*
Piping Lift ft.
25
30
Pipe Connection Size - Liquid (In)
1/4
3/8
Pipe Connection Size - Suction (In)
3/8
1/2
5/8
Voltage
115 -1 -60
208-230-1-60
Power Supply
Indoor unit powered from outdoor unit
Outdoor - MCA
19
19
10
14
16
Outdoor - Fuse Rating (MOCP)
30
30
15
20
25
29.9 x 23.2 x 11.2
33.3 x 27.6 x 12.6
Dimensions (W X H X D) In (net)
30.7 x 21.2 x 9.8
Outdoor Net Weight (lbs.)
70.5
82.7
103.6
Sound Pressure dBa ( Clg / Htg )
57
58
60
61
Dimensions (W X H X D) In (net)
26.8 x 10.0 x 7.0
30.3 x 10.0 x 7.4
35.6 x 10.8 x 7.8
40.6 x 12.4 x 8.6
Net Weight (lbs.)
15.4
16.5
19.8
26.4
Number of Fan Speeds
4
Airflow (lowest to highest) CFM
131/160/192/215 158/194/230/240 157/193/232/240 236/294/348/395 368/458/547/580
Sound Pressure dBa (L / M / H) Clg
43/39/34
44/40/36
44/40/36
45/41/37
50/46/42
Sound Pressure dBa (L / M / H) Htg
40/35/30
43/38/33
42/36/31
42/38/33
46/42/38
6
UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution
REMOTE CONTROLLERS
Temp down
Temp Up
MODE
FAN speed
Swing
TIMER ON
Sweep
TIMER OFF
Turbo
LED / F.P
SLEEP
Wireless remote controller
Wired remote controller (Optional)
7
UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution