Outdoor
PISC-C201A
48W Dimmable Power
24V / 2A / 48Wmax
▶ Mechanical Outline
(Metal Case)
-138 x 47 x 32mm
Features
▶ Dimmable Type : 0 -10 Dimming
▶ Constant Voltage / Constant Current Control
※ Mass Production : Feb. 2013
※ Sample Availability : Available
▶ High Efficiency
▶ High PF(>0.9) and Low THD(<20%)
▶ Protection : OVP, SCP, OTP, OCP
Critical Specifications
Input
Voltage
Output
Voltage
Output
Current
Output
Power
Efficiency
THD
Power
Factor
108 - 305VAC
24VDC
2.0A
Max. 48W
> 85%
< 20%
> 0.9
Input Specifications
Parameter
Min
Typ.
Max
Unit
Remark
Input Voltage
108
-
305
VAC
Input Current
-
-
0.6
A
Input Frequency
50
-
60
Hz
Power Factor
0.9
-
-
PF
At Over 75% Output Load
Inrush Current
-
-
TBD
Apk
Meet NEMA410
Min
Typ.
Max
Unit
Output Voltage
-
24
26.7
V
Output Current
-
2
-
A
Automatic set by external
resistor (Rset)
Output Dimming Current Range
10
-
100
%
0 -10 Dimming
Line Regulation
-5
-
+5
%
Output Ripple & Noise
-
-
10
%
Start-up Time
-
-
750
ms
Output Specifications
Parameter
Remark
Peak-peak 20MHz
Bandwidth
Datasheet is subject to change without notice.
Revised 31 August 2012 (REV. 1.0)
1
www.lginnotek.com
Outdoor
Protection Functions
Parameter
Min
Typ.
Max
Unit
26.7
V
Constant Voltage with
Limiting
A
Auto Recovery
Output Over Voltage Protection
Output Short Circuit Protection
2.1
Input Under Voltage Protection
VAC
Remark
-
Reliability Specifications
Parameter
Min
Typ.
Max
Unit
Remark
-
50
-
kHr
@ Tc=60℃
-
-
-
kHr
@ Tc=70℃
-
-
TBD
%
@ Tc=60℃, early 500Hr
-
-
10
%
@ Tc=60℃, 50KHr
Life Time
Failure Rate
MTBF
kHr
Environmental Specifications
Parameter
Min
Typ.
Max
Unit
Operating Temperature
-25
-
80
℃
Case temp.
Storage Temperature
-30
-
90
℃
Ambient temp.
-
-
%
Relative humidity for
operation
-
-
%
Relative humidity for
storage
-
Humidity
-
Remark
Standards
Parameter
Condition
Remark
- UL8750, evaluated to UL1310
Safety Standards
- CE
Protection type :
Manual resetting type
- ENEC
- IP65
- EN 55015:2006+A1+A2
- EN 61547:2009
EMI / RFI Standards
- EN 61000-3-2:2006
- EN 61000-3-3:2008
- FCC part 15, Class B verification
Datasheet is subject to change without notice.
Revised 31 August 2012 (REV. 1.0)