Customer Days Amsterdam 02-2010
Bosch “Fire Evac”
Two Systems
one Solution
one Brand
Josef Angstenberger
Security Systems
1
Internal | ST/PRM2-EU | 27.01.2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all
rights of disposal such as copying and passing on to third parties.
Customer Days Amsterdam 02-2010
Fire System
EVAC System
• Detect
Inform
• Notify
• Evacuate
Evacuate
Two ways of Evacuation:
 Via Fire System
 Via EVAC System
Security Systems
2
Internal | ST/PRM2-EU | 27.01.2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all
rights of disposal such as copying and passing on to third parties.
Customer Days Amsterdam 02-2010
Different applications require different solutions
Big/high
EVAC
 With increased project
size and complexity
the demands on Fire
and EVAC grow.
Fire
Project
size and
complexity
 Solutions for low and
high complex projects
are needed
Small/low
Size and complexity of
Fire/EVAC solutions
Big/high
 The better the
communication
between the Fire and
EVAC systems the
better the safety
solution
Security Systems
3
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
EVAC
Fire
Fire-EVAC solutions from Bosch
Solutions by
Bosch
Direct connection
• RS232 interface
• Relay contacts
Platform connection
• Bosch BMS BIS
• Connection to 3rd
party BMS
Security Systems
4
Internal | ST/PRM2-EU | 27.01.2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all
rights of disposal such as copying and passing on to third parties.
Customer Days Amsterdam 02-2010
EVAC
Fire
High quality communication - Requirements

Supervised connection

Operational reliability and stability

Easy to connect and install (standard solutions needed)

Flexible to adopt to changes and extensions

Good price / performance ratio
Security Systems
5
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
Relay solution
RS232
solution
no


Status info
None
Specific fault messages
from Plena to Fire Panel
Specific fault messages
Flexibility
Only via HW changes and
SW adoptions
No additional HW, only
changes in configuration
No additional HW, only
changes in configuration
HW needed,
cable connection
Grows with EVAC zones
One cable per EVAC zone
1 module – always
One cable - always
One connection - always
One cable - always
Installation,
programming
Cable connection per zone
Programming per zone
Programming per zone
Programming per zone
System limitations
According to max. # of
relays
Limited only by EVAC
system
“No” limits
Supervised
connection?
Security Systems
6
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
BIS
Customer Days Amsterdam 02-2010
Fire - EVAC
One solution from one brand
What does this mean for you?
Security Systems
7
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
Be more competitive in tenders
Besides the known advantages from Bosch Fire and EVAC

Proven Solution from one company increases trust in the solution

Very limited “internal” competition (your invest in the project will be your
benefit)

Unique interface solution with RS232 for FPA-Plena for tenders
Security Systems
8
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
Save capacities through reduced installation costs and time

RS232 interface between FPA family and Plena




One interface cable instead of multiple HW connections (reduced
cabling time)
SW solutions allow customized solutions
Supervision and diagnostic info by default (no work around needed)
Standard connection to BIS from Praesideo/Plena and FPA family


Same working principle for both Fire and EVAC
Proven solution with operational stability
Security Systems
9
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
Competitive advantage due to reduced HW costs

RS232 interface between FPA family and Plena



One interface cable instead of multiple HW connections
No extra HW on the panel
Supervise connection by default
RS232
solution
FPA
Plena
Effect on the fire system
Relay
solution
•More Relay cards
Extension
FPA
Plena
other
HW
• More cable
• Bigger housing
• Higher risks of fault
Security Systems
10
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
Flexibility in system design and extension

Future changes can be done quickly by SW changes
(no re-cabling of the connection needed)

No limitations for system extensions
(RS232 interface, BIS platform)

Proven standard solutions for any size of application and requirement
(the system grows with your needs)
Security Systems
11
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
Reliability and operational security





Supervised RS232 connection
Specific trouble event of EVAC zones are displayed at the Fire
panel
No risk of poor relay connection thanks to SW solution and
standard connectors on RS232 cable
With solution out of one hand (BIS, Fire, EVAC) all interfaces
extensively tested and approved
All systems are EN 54 certified
Security Systems
12
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
Some examples of Bosch Fire-EVAC integration
Security Systems
13
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
Maaspoort Sports & Events, ‘s-Hertogenbosch

Praesideo with Power Supply Amplifiers

Loudspeakers of different types

Modular Fire Panel 5000 Series

Fire Detector 420 Series
Manual Call Point 420 Series
Interface Module 420 Series


Bosch´s „one-stop-shop“ unique integration of voice evacuation and fire alarm systems was
decisive for the customer, as it facilitates fast warning and phased
evacuation in this complex environmental conditions.
Security Systems
14
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
High School in Halbergmoos (Bavaria)

Plena Voice Alarm System

120 Loudspeakers

14 Public Address Zones

FPA-5000 Fire Panel

110 Fire Alarm Detectors

15 Controls
“So far we are extremely satisfied and will definitely bear this system in mind for future construction
projects.”
Security Systems
15
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
Multi purpose sports Arena in Zagreb

> 2000 Loudspeakers

Praesideo

2.000 Fire alarm detectors

Networked FPA-5000

Both, Praesideo and FPA-5000 are networked to
BIS
“Bosch Building Integration System is the suitable solution for that as it not only accepts the alarm
signals from every systems but it is capable to start predefined procedures which influences other
systems operation. These alarm triggered scenarios seriously support the operators’ job.”
Security Systems
16
Internal | ST/PRM2-EU | 9/11/2009 | © Robert Bosch GmbH 2009. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Customer Days Amsterdam 02-2010
Bosch “Fire Evac”
Connect to EVAC FPA family via
• Serial interface RS232
• Relay contacts
• Bosch BIS
• SW-solution for 3rd party BMS connection
Benefits
• More competitive in tenders
• Save installation capacities
• Reduced HW and installation costs
• Future proof – flexibility in design and extension
• Reliability and operational security
Security Systems
17
Internal | ST/PRM2-EU | 27.01.2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all
rights of disposal such as copying and passing on to third parties.
Customer Days Amsterdam 02-2010
Back up
Security Systems
18
Internal | ST/PRM2-EU | 27.01.2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all
rights of disposal such as copying and passing on to third parties.
Customer Days Amsterdam 02-2010
System Size and
applications
Fire System
Evac System
Large applications
Hotels, 7-16 story building,
big office buildings, production
sides
512 – 2000 detectors
Low rise office, college,
Apartments, manufacturing
Extra small applications
Church, schools,
areas of assembly
127 – 512 detectors
<127 detectors
+ conventional
FPA 1200
Small applications
Security Systems
19
Internal | ST/PRM2-EU | 27.01.2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all
rights of disposal such as copying and passing on to third parties.
Praesideo
Middle sized applications
Plena Voice Alarm
>2000 detectors
FPA 5000
Airports, military apps,
Buildings > 16 stories
> 2 channels
zones >60
1-2 channels
zones <60
1 channel
zones <12
1 channel
<4 zones