Transcript Slide 1

Adapting to people & the environment

System Overview • Workspace specific • Quality illumination • Personal dimming control • Occupancy sensors • Daylight dimming • Peak load management • Scheduling/Reporting

Workspace specific lighting • One Ergolight per standard workstation • Positioned directly over work area • Puts light where it is needed

Standard troffer layout: 26 fixtures

Workspace specific layout: 13 fixtures

Application Photo

Quality Direct/Indirect Lighting • Center lamp distributes light upwards, reflects off ceiling • Provides uniform ambient light / Softens shadows • Eliminates cave-like room appearance • Outer lamps deliver extra light on desk-top for enhanced visibility • Louvers control glare on computer screens

Constant up-light in open spaces Up-light unaffected Personal Dimming Daylight Dimming Occupancy Sensing

Occupancy and daylight sensing • Overhead sensor location= reliable sensing • Gradually dims outer lamps to 10% after time delay • Holds at 10%, before turning lamps off • Over 30% energy savings in window adjacent locations • Gradual dimming avoids sudden changes in levels • Maintains constant light level at work plane

Cubicle Illuminance

Ceiling Height

8’ 9’ 10’ 11’ 12’

8’x8’

48.5 fc 46.8 fc 44.8 fc 42.3 fc 40.4 fc Workspace Dimensions

8’x10’

45.2 fc 44.0 fc 42.3 fc 40.1 fc 38.4 fc

10x10’

35.5 fc 33.4

31.3 fc 29.2 fc 25.2 fc Reflectances 80/50/20. Cubicle Walls 5’ @ 50% reflectance. T8 Lamps. LLF .9

Personal Dimming Control • On-screen control panel • Users select preferred light level • Ceiling light stays constant

System-wide management • FM has full control over entire Ergolight network • Entire network can be gradually dimmed for load shedding • Events can be scheduled on daily/weekly/monthly basis

Detailed energy reporting

Load shedding and sensor commissioning • Avoid peak demand charges with load shedding • Commission sensors with the click of a mouse

How it works: The Lighting Network

Where the energy savings come from

Where the energy savings come from

Where the energy savings come from

Where the energy savings come from

Where the energy savings come from

Proven results with Ergolight Controls Reynolds Metals 87% (retrofit) Raytheon 83% (retrofit) BC Hydro 78% (new construction)

Actual 3 rd party results • BC Hydro – Comparison Study 9

Weekly Power Profile Comparison 8th floor (Ergolight) vs. 5 th – floor (Reference

) 8 5 4 7 6 3 2 1

Power (kW)

0 Monday Tuesday Wednesday Thursday

Time (Hour)

Friday CPP 8 Ergolight CPP5 Open Offices Saturday Sunday

Light Right Consortium: Albany, NY • A comprehensive study on worker satisfaction and productivity

3 aesthetic mounting options

Other options Available with T8 or T5 lamping