Modulmatic - Lmb Europa

Download Report

Transcript Modulmatic - Lmb Europa

Package for Non-Electricity
Blood Banks(NEBBs)
LMB gathered the crucial equipments into one package, which is
enough to conduct a blood bank, which is suffering shortage of
electricity.
What are the problems of NEBBs?
How to avoid expensive equipment during the Collection / Testing /
Separation / Storage / Handling of Blood and Blood Components.
How to seperate “a donated blood” without the electricity driven
centrifuges or expensive seperation devices?
How to control the donations, make necessary tests on, conduct the
storage and handling process under the shortage of electricity?
The answers of above questions are embedded into LMB Package
solution for NEBBs. Let’s review one by one all equipments and
their convenient facilities for NEBBs.
A package is enough for fulfilling
the main functions of NonElectricity Blood Banks (NEBBs!)
1. Blood collection
2. Blood transport
3. Blood testing
4. Blood separation
5. Blood storage
6. Blood transfusion
model 1
model 2
1. Equipment for donation
Bagmatic Novo
1. Equipment for donation
Bagmatic Novo
1. Equipment for donation
Mobile Donor Lounge
1. Equipment for donation
Sealer
1. Equipment for donation
Manual Tube Stripper
1. Equipment for donation
Manual Tube Stripper
1. Equipment for donation
HB photo meter
1. Equipment for donation
HB photo meter
2. Equipment for blood transport
Transport box – silver bags
3. Equipment for blood testing
Eldoncard for blood group typing
In particular suitable for blood typing
•in the practitioner's clinic
•at the bedside prior to transfusion
•in your home
•on remote locations
•in emergency situations
•on board ships and oil rigs
•on the battlefield
Special Qualities
•Personal, lifelong record of bloodtype
•Doctors documentation of agglutination
•Long shelf-life at ambient temp.
•Safe, easy and fast (2 minutes)
•Bloodtype while you watch
•Low priced mono-clonal technique
3. Equipment for blood testing
Eldon card for blood group typing
3. Equipment for blood testing
Rapid tests for infectious diseases: Hepatitis B & C
HepaGnost B PK test plate- 1x10 tests,
quickly detection of hepatitis B antigens in blood and serum
HepaGnost B panel- 1x5 tests,
rapid detection of 5 hepatitis B markers in serum
HepaGnost C PK test plate- 1x10 tests,
rapid detection of hepatitis C antibodies in blood and serum
3. Equipment for blood testing
Rapid tests for infectious diseases: HIV
HIV-1/2 test plate- 1x10 tests,
rapid detection of HIV antibodies in serum
PK HIV-1/2 PK test plate- 1x10 tests,
rapid detection of HIV antibodies in bood and serum
3. Equipment for blood testing
Rapid tests for infectious diseases: Malaria
3. Equipment for blood testing
Rapid tests for infectious diseases: Syphilis
SyphiGnost PK test plate- 1x10 tests,
detection of Treponeme palide antibodies in blood and serum
4. Equipment for separation
ErySep
What is ErySep®?
ErySep, which is our newly validated technology for blood component separation, by
Gravity. It is a blood separation system, which separates whole blood into its
components without CENTRIFUGE and EXTRACTOR.
•
•
•
•
Blood Components, Anytime & Anywhere – The first and only blood component
separation disposable kit, which allows the immediate separation of fresh donor blood
into “cell-free plasma” and “erythrocytes” with or without leuko-depletion thereby
extending component therapy for all, especially, difficult rural conditions
No Technical Systems or Equipment Necessary – There’s absolutely no need for
expensive refrigerated centrifuges or plasma extractors, and the consequent need for
maintenance of these equipment with trained personnel, as well as the requirement
of constant and good electricity to run these expensive equipment.
No Specialist Knowledge, No Special Storage, No Maintenance – Manufactured under
completely sterile conditions, the ErySep pack’s only 520g and is therefore very
portable around the country, to be operated only by nurses during donation of blood
after which it’s separated by gravity, through a hollow fibre filtration set resulting in
one unit of “cell free plasma” and one unit of “erythrocytes” with or without leukodepletion, while the rest of the system becomes biomedical waste
Clinical Outcome proven and published – ErySep is patented and certified with
ISO13485:2003 and follows latest 11th published Edition of European Guidelines.
4. Equipment for separation
•
•
It is only a disposable product
– 1 whole blood bag
– 2 red cell bag
– 3 plasma bag with an integrated air
drainage bag
– 4 has standard leukocyte filter
– 5 has test bag with vacu-container port
– 6 has membrane filter embedded into
separation chamber unit
WHY ERYSEP?
– ErySep is user friendly
– No necessary special education
– It is activated in 5 minute, and no need extra efforts
– Staff can do their other daily work
– ErySep complete process by itself within
75 minutes.
– ErySep is a Closed Sterile System
– It can not effect outside conditions
– Cost Reduction
– No centrifuge & extractor investment
– No maintainance cost in rutune
– No power supply
– Easy Handling
– 24 month shelflife in room condition
– Easy Product exchange & replacement
– Portable & ready work wherever needed
ErySep
4. Equipment for separation
Medical ADVANTAGES of ErySep®
– ErySep supplies Leuko-depleted
Red Cell & Plasma
– Erysep supplies high HTC level
into the Packed Red Cell Bag.
– ErySep supplies plasma, which is
ready for FFP
– ErySep supplies Packed Red Cell
Bag, which can be store 42 days.
– Leuko-depleted components are
precious for Oncology and
Hematology Patients
– Make available the fresh
components at hospital for
surgical operation purposes.
– Make available the fresh
components for the patients need
routine transfusion at hinterland.
ErySep
4. Equipment for separation
ErySep study
WBC
RBC
4 - 11
[10ᶟ/mmᶟ]
4 - 6,1
[10⁶/mmᶟ]
BANGLADESH DOH_1
Red Cells
0,24
BANGLADESH DOH_2
Red Cells
HGB
HCT
PLT
11 - 16,1 g/dl
38 - 52 %
140 - 400
[10ᶟ/mmᶟ]
PCT
6,89
18,2
81,3
2
-
0,01
5,79
17,6
54,5
0
MYANMAR No.2 Military Host
Red Cells
0,1
5,84
14
41,3
MYANMAR No.2 Military Host
Plasma
0,1
0
0
MYANMAR No.1 Military Host.
Red Cells
0,1
6,65
MYANMAR No.1 Military Host.
Plasma
0,3
0,01
MCV
MCH
MCHC
26 - 31 pg
31 - 37 g/dl
94,1
26,4
32,5
0
94,1
30,4
32,3
38
0,048
71
24
33,9
0
0
0
0
0
0
16,4
44,9
96
0,146
67
24,7
36,6
-
-
38
0,029
-
-
-
.100 - .500 % 80 - 94 µmᶟ
4. Equipment for separation
ErySep study
WBC
RBC
4 - 11 [10ᶟ/mmᶟ]
4 - 6,1
[10⁶/mmᶟ]
Parami Children hospital 1
Red Cells
0,05
Parami Children Hospital 2
Red Cells
MYANMAR Child Hospital 1
Red Cells
HGB
HCT
PLT
11 - 16,1 g/dl
38 - 52 %
140 - 400
[10ᶟ/mmᶟ]
PCT
5,86
14,5
43,9
18
-
0,06
6,13
16,8
52,5
30
0
6,17
17
55,6
Turkey Hisar Hospital
Red Cells
0,03
6,24
18,4
Turkey Hisar Hospital
Plasma
0,03
0,03
0
MCV
.100 - .500 % 80 - 94 µmᶟ
MCH MCHC
26 - 31 pg
31 - 37 g/dl
74,9
24,7
33
-
85,6
27,4
32
3
0,002
90,1
27,6
30,6
56,8
22
0,02
91
29,5
32,4
0,20
3,00
0
66,70
0,00
0,00
4. Equipment for separation
Manual Plasma Extractor
5. Equipment for blood storage
Dometic refrigerator & freezer
Plasma
– 20°C
Technical data:
• Outside dimensions: 1290x790x1030 mm
• Inner freezer gross volume: 48 l
• inner refrigerator gross vol: 161 l
• operates after charging for about 50
hours
• CFC and HCFC free
• insulation of 100 mm polyurerhane
• rust resistant
• 4 wire baskets
Red Cells +
4°C
• lockable lit
• Hold over time during power cut out: at
+43°C ambient 50 hours
5. Equipment for blood storage
Plasma Thawer
• Sealed, temperature
controlled water bladder
for an even heat transfer
• Fast heat up (< 8 min.)
• 33 x 41 X 20 cm
• less likley to compromise
sterility
6. Blood transfusion
Before blood transfusion Crossmatch is
necessary!!!
patient
donor
Results must match!!!
Thank you very much!
Your contact for questions is