Definition of a basic Installation
•
What’s included in the TrueSTEAM™ box
•
Step by step Installation Instructions
•
Cautionary measures for avoiding common installation mistakes
•
What homeowners can expect after a TrueSTEAM™ installation
What’s Included in the TrueSTEAM Box?
Tools and Parts Needed
•
Tools needed to install TrueSTEAM™
Wire cutter/stripper Torx driver T-20 and T-30 Standard screwdriver 1-3/4-in. diameter hole saw 1/8-in. drill bit 18-gauge wire (up to 5 conductor) •
Other Optional Parts:
Condensate pump rating of 212 °F (100°C) if used. Drip pan with water sensor shut-off required underneath TrueSTEAM if installed in or above finished space.
Tips and Precautions
•
Be sure to read and understand the Installation Guide and complete list of precautions before starting work!
-
Adhere to voltage, heavy equipment and hot water warnings in the manual
-
Comply to all install, plumbing, wiring guidelines in the manual, as well as those listed in your local guidelines
-
Wear safety glasses
•
Do not install in locations which are:
-
Outside operating temperature range: 34 °F to 104°F
-
In confined space (less than 1 foot of clearance)
-
Exposed to outside weather DEDICATED TRUESTEAM HOTLINE 800-814-9452
Step 1: Choosing a Location Choose a location that has access to a:
• • • •
Vertical surface with adequate clearances. Cold water supply line must be used.
Drain with a high-temperature water rating.
Electrical circuit rated to your humidifier.
Model HM506 HM509 HM512 Required Minimum Circuit Capacity 7 Amps 10 Amps 12 Amps
Step 2: Mounting on the Supply Duct
•
Position template on supply duct, and ensure proper clearances from A-coil.
Step 3: Mount Bracket
•
Secure bracket to duct using provided self-drilling sheet metal screws.
Step 4: Insert Duct Nozzle
•
Install duct nozzle by ensuring o-ring gasket is properly seated in the groove, and slide foam gasket down over nozzle.
•
Insert nozzle and twist clockwise to ensure tight seal of nozzle to TrueSTEAM.
Step 5: Mounting TrueSTEAM
•
Push down to secure humidifier to bracket arms.
•
Ensure gasket forms tight seal in duct hole.
•
Allow 4 inches clearance from nozzle outlet to any duct wall and allow 24 inches of downstream open duct air space to prevent duct condensation.
Step 6: Plumbing Use only cold water. Do not use hot water supply.
a.
Water Filter. Insert 1/4-inch copper or plastic water line. Apply modest pull to ensure a tight fit.
b.
Back-flow preventer valve. Insert 1/4-in. copper or plastic water line. Apply modest pull to ensure a tight fit.
c.
Connect 1/2-in. drain tube. Secure drain tube to barbed fitting with hose clamp.
d.
Shut off the water supply. Secure 1/4-in. copper or plastic water feed tube.
Step 6: Plumbing
After Installation
•
Educate the homeowner on what to expect next.
•
It may take up to a week of continuous operation to achieve the humidity control set point.
•
A slight plastic smell may be detectable the first week of operation. This is normal and will dissipate after running a short time.
•
There may be a slight increase in the homeowner’s energy bill even when TrueSTEAM™ is sized and operating correctly. Set the expectation that comfort costs money to avoid callbacks.
Support Materials
•
Additional Materials on TrueSTEAM Installation are available.
•
Visit www.forwardthinking.honeywell.com
-
Click on Humidification
•
Enter literature form: #69-2285: TrueSTEAM Installation Manual
Module 3 – Basic Installation
•
Definition of a basic Installation
•
What’s included in the TrueSTEAM box
•
Step by step Installation Instructions
•
Cautionary measures for avoiding common installation mistakes
•
What homeowners can expect after a TrueSTEAM™ installation.