Transcript Slide 1

Product overview
FMNA Automatic Fire
Suppression System
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
Overview
System overview:
- Top level overview
- Component overview
- Assembly / Mounting options
Benefits:
- Proven technology
- Worldwide applications
- Certifications
- UL update
- SBF128
- Performance of system
- Environmental implications
- False activations / clean-up
- Next Steps / Q&A
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
System Overview
Top Level
Stainless
steel
routing
LOP Detection Tube
Piston
Accumulator
Detector
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
System Overview
Detection
Loss Of Pressure (LOP)
- Strategically routed throughout the protected compartment.
- Bursts or melts at ~375º F opening release valve
- Simple pneumatic activation, does not require electricity
- Eliminates false activations due to electrical issues
- Manual activation option
Other Options:
- Spot thermal sensors
- Linear thermal wire
- Manual push button activation
- Methane detection
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
System Overview
Piston Accumulator
- Patented design
- 4L (small bus), 6.5L & 7.5L (large bus) systems. Option
to gang PA’s together for larger vehicles.
- Stores / releases H2O mix
- System charged to ~950 PSI and provided continuous
flow for 40-70 seconds.
- Mounts and works in any orientation, no system
orientation concerns (rollover, etc)
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
System Overview
Nozzles
- Patented spray nozzles deliver 2000
atomized droplets (80 micron) per 1mm
droplet
- Spray is a 90° coned shape pattern
- Water mist flashes to steam and can be
indirect to the fire
- Nozzle covers to prevent contamination
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
System Overview
Assembly / Mounting Options
- Piston accumulator can mount in any
orientation allowing for more mounting options
than powder systems.
- 6 inch diameter allows for tight space clams.
- Alarm panel monitors system pressures and
controls engine shutdown.
- Optional fire button allows for manual deploy.
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
Benefits
Proven Technology
- 70,000+ systems installed worldwide
- Fogmaker is the leading fire suppression supplier in the European and Australian bus
market. Fogmaker is the preferred system for Mercedes & Volvo in Europe.
- UK overview: Total fleet of ~600 with Fogmaker, 33 known incidents over 4 years with all
being suppressed without issue and minimal damage.
- Australia, we have installed well over 1000+ Government Buses with Fogmaker and we
have to date had approximately a dozen thermal events with buses fitted with the System.
In all cases, the system has detected & suppressed the fires with little or no damage with
exception to “what” caused the initial fire (ie cracked fuel rail, electrical arcing, broken lines /
hoses, debris etc.)
- Over 1000 buses in US and Canada are now using Fogmaker – UL Listing was requested
by some larger customers.
- CNG application in Tempe with NFI, very happy to date and positive result on incident
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
Benefits
UL Listing update
• Officially listed UL product as captured under listing for Fogmaker NA
• Listing is per UL Subject 1384
• Testing consists of system level detection / suppression testing as well as
multiple component level tests (over 100 total tests in all)
• Only system UL approved for ‘self-contained automatic extinguisher
units’ as other approvals relate to total flooding and do not cover complete
automatic detection systems
• Listing can be found at www.UL.com
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
Benefits
SBF128
- Testing method was that of SBF128
(Full-scale extinguishing trials of water mist in a bus fire)
- SBF128 is a Swedish test protocol executed by SP (Science Partners) and tied
to the Insurance Institute
- Overview of the test
- 20 min preheat of bus (15 @ idle, 5 with throttle)
- 7 pounds of woodchips presoaked for 24 hours with a diesel / oil mixture
placed throughout engine
- Cotton rags presoaked with above mixture also placed throughout
- 1.5 liters of Diesel / oil sprayed throughout
- Ignite engine compartment with torch
- Close and burn for 20 seconds
- Manual activation of the fire suppression system
- Continue to run engine / fan at idle speed
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
SBF 128 Test protocol
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
Benefits
Performance
- Attacks all 3 elements of the fire triangle:
- Heat: Water mist cooling effect.
- Fuel: AFFF (Foam) blankets the fuel
- Oxygen: Steam chokes out the oxygen
- Longer cooling & suppressing time
- 40-70 seconds continuous
- Re-flash prevention
-Hot surfaces are cooled below flash temps
-Any remaining fuel is covered by the
AFFF (Foam)
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
Benefits
Environmental
- No hazmat required
- Fast easy clean-up
- Not harmful to people
- Not harmful to equipment
- Water mist
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
Benefits
False Activations / Clean-up
- LOP requires no electricity or operator involvement thus reducing false
activations due to electrical shorts & operator error.
- Clean-up is fast and only requires pressure washing of protected area.
- PA & detector can be recharged in vehicle or exchanged for an in-stock
replacement.
- The system can be recharged in under 1 hour by trained personnel on site.
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.
Questions / Next Steps
THE INFORMATION CONTAINED OR DESCRIBED IN THIS DOCUMENT IS PROPRIETARY TO
USSC GROUP, AND MAY NOT BE REPRODUCED, DIVULGED OR USED WITHOUT WRITTEN
PERMISSION FROM USSC GROUP.