Carr Centritech Separation Systems
Download
Report
Transcript Carr Centritech Separation Systems
Carr UniFuge
Single-Use Separation
System
Customers Across the Globe
United States
Germany
Canada
France
Mexico
Austria
Brazil
Italy
U.K.
Japan
Sweden
Belgium
Australia
Denmark
Switzerland
The Netherlands
Wyeth
CELL SEPARATION
LIQUID/SOLID
2,400 L/hr
CARR P18
Powerfuge
CARR
ViaFuge V12
500 L/hr
CARR P12
Powerfuge
100 L/hr
Centritech
CELL
CARR
ViaFuge
&
UniFuge
10 L/hr
Centritech
LAB
450xg
CARR
P6 / Pilot
Powerfuge
Pilot
10,000xg
20,000xg
New Product Update
UniFuge
Single-Use Cell Harvesting
Technology
CONFIDENTIAL
Design Objectives
Robust, single use cell harvesting centrifuge
Scalable platform
Harvest capacity of 10L to 2,500L bioreactor
Pilot ≈ 3L/min with1.5L cell volume collection
Production ≈ 20L/min with 40L cell volume
collection
Gamma irradiated single use liner
Fully automated processing
High recovery of cells with minimal cell lysis
CONFIDENTIAL INFORMATION
DISCLOSURE FOR ‘A’ The information
contained in this document contains
privileged and confidential information. It
is intended only for the use of the
person(s) named above. If you are not
the intended recipient, you are hereby
notified that any review, dissemination,
distribution or duplication of this
communication is strictly prohibited.
Process rates allow for single shift harvesting
UniFuge®
Concept, Prototype & Testing
Dec 2007 - Concept
Mar. 2009 – Alpha unit mammalian cell test
Oct. 2009 – Beta unit field trials begin
Alpha Prototype
Beta Prototype
UniFuge®
Design Concept
Solid Bowl Centrifuge
Reinforced & contained flexible single-
use component
Semi-continuous, automated cell
processing
Programmable feed & harvest cycles
Intermittent cell concentrate removal
Closed loop operation
Gamma irradiated disposable liner
Sterile connections for feed, centrate
CONFIDENTIAL INFORMATION
DISCLOSURE FOR ‘A’ The information
contained in this document contains
privileged and confidential information. It
is intended only for the use of the
person(s) named above. If you are not
the intended recipient, you are hereby
notified that any review, dissemination,
distribution or duplication of this
communication is strictly prohibited.
& concentrate
Rotating mechanical seal, no
process contact
UniFuge®
Single Use Component
Rigid + flexible components
Tube set is integrated as part
of single use component
Terminally sterilized (gamma)
Complies with:
ISO 10993
USP <87> & <88>
Class VI plastics
Polycarbonate
Polyurethane
Polypropylene
C-Flex
Silicone
UniFuge®
Overview
Automatic pinch
valves
Feed In
Concentrate Out
Supernatant Out
Ultrasonic sensor
Peristaltic feed &
harvest pump
Single-use
pressure sensor
Onboard air supply
and sterile filter
Fiber optic level
sensor
Cooling jacket
supply connect
RPM Sensor
UniFuge®
Automated Processing
Auto & manual modes
Setup integrity test mode
Controlled parameters
Bowl speed / G-force
Feed flow rate
Fill volume (flow rate / time)
Cycle time
Discharge time
Number of cycles
Monitored Parameters
Supernatant line pressure
Air pressure
Vibration (accelerometer)
Calibration screens
Alarms
UniFuge® Pilot
Layout
25” (635mm)
57” (1448mm)
Process connections:
Electrical: 230VAC, 1 phase, 50/60Hz, 15A
Feed supply: up to 4Lpm, ½” weldable tubing
Cell concentrate discharge: ½” weldable tubing
Supernatant discharge: ½” weldable tubing
Cooling (optional): ¼” FNPT 4LPM @ 70KPA; -25° to´+20° C
UniFuge®
Pilot Prototype
UniFuge®
Pilot Prototype
UniFuge®
Development Tests
Alpha Unit 3/4/09
Beta Unit 8/26/09
Objective: separation
Objective: separation
performance
20L CHO Cells
performance, lysis, viability
20L SF9 Cells
Feed: 1.15x106 cells/ml
@ 95% viability
CONFIDENTIAL INFORMATION
DISCLOSURE FOR ‘customer’ The
information contained in this document
contains privileged and confidential
information. It is intended only for the
use of the person(s) named above. If you
are not the intended recipient, you are
hereby notified that any review,
dissemination, distribution or duplication
of this communication is strictly
prohibited.
Feed: 6x106 cells/ml @
73% viability
Three tested conditions
1, 2 & 3 L/min
2,000 x g
Three tested conditions
1, 2 & 3 L/min
2,000 x g
Cell Capture Results
1 L/min: 99.99%
2 L/min: 99.8%
3 L/min: 98.6%
Cell Capture Results
1 L/min: 99.99%
2 L/min: 99.9%
3 L/min: 98.8%
UniFuge®
Supernatant Separation Results
CONFIDENTIAL INFORMATION
DISCLOSURE FOR ‘customer’ The
information contained in this document
contains privileged and confidential
information. It is intended only for the
use of the person(s) named above. If you
are not the intended recipient, you are
hereby notified that any review,
dissemination, distribution or duplication
of this communication is strictly
prohibited.
UniFuge®
Prototype Turbidity
CONFIDENTIAL INFORMATION
DISCLOSURE FOR ‘customer’ The
information contained in this document
contains privileged and confidential
information. It is intended only for the
use of the person(s) named above. If you
are not the intended recipient, you are
hereby notified that any review,
dissemination, distribution or duplication
of this communication is strictly
prohibited.
UniFuge® Pilot
Customer Field Trails
Customer Trial #1 – preliminary results, awaiting formal summary
CONFIDENTIAL INFORMATION
DISCLOSURE FOR ‘customer’ The
information contained in this document
contains privileged and confidential
information. It is intended only for the
use of the person(s) named above. If you
are not the intended recipient, you are
hereby notified that any review,
dissemination, distribution or duplication
of this communication is strictly
prohibited.
Objective: Harvest with recovery of viable cells
Cell
Line
Volume
Flow rate
G-force
Feed
Viability
Harvest
Viability
% Loss in
supernatant
CHO
56L
3 L/min
2,000
99%
~98%
1.68%
CHO
50L
4 L/min
3,000
95.4%
97.3%
Negligible
CHO
57L
5 L/min
3,000
98.6%
98%
2.97%
CHO
90L
4 L/min
3,000
96.2%
98.6%
-
UniFuge® Pilot
Customer Field Trails
Customer Trial #2 – preliminary results, awaiting formal summary
Objective: Clarification & Harvest from Wave Bag BR
Cell
line
Batch
size
Flow
rate
CHO
10L
Sf9
10L
Baculovirus
infected
CONFIDENTIAL INFORMATION
DISCLOSURE FOR ‘customer’ The
information contained in this document
contains privileged and confidential
information. It is intended only for the
use of the person(s) named above. If you
are not the intended recipient, you are
hereby notified that any review,
dissemination, distribution or duplication
of this communication is strictly
prohibited.
Concentrations
Feed
Concentrate
Supernatant
1 Lpm
3.03x106
21.2x106
.003x106
1 Lpm
4.1x106
17.91x106
.049x106
UniFuge®
Summary
•
Benefits
– Centrifugation
•
Improved separation performance means less downstream
processing
•
Better suited for high titers – no blinding or fouling of filters
– Single Use Technology
•
Lower cost due to less cleaning/sterilization - No CIP/SIP required
•
Less product losses due to contamination
– Programmable automatic processing
•
Variable separation force
•
Optimize feed flow rates
•
Programmable harvest cycle time
– Capable of recovering and concentrating viable cells
– Reduced downstream filtration
– Scalability, Pilot -> Production
UniFuge®
Next Steps
Unit(s) available for field testing in US and Europe
Typical field trial period is for one (1) week and includes
on site technical support
Each customer will purchase the disposable liner(s)
needed for testing
The beta test single-use components will not be gamma
irradiated
Unifuge Pilot is available for sale, estimated delivery is
12 weeks