Transcript Slide 1

2010 – Railway Overview

Heike Saadatpour CE & SEE Territory

22 Years of Excellence

Company Overview

• • • • • Founded 1988, privately held Offices in Southern California (Head Quarters), Clearwater, FL, and Aarschot (Brussels), Belgium 80+ employees US-designed and made products 6 years warranty including fans & power supplies (except SFP’s -1 year)

Railway Applications in Europe

1) IP-Cam surveillance application

 IE-MiniMc installed  Main railway stations in Europe

2) TrainInfo displays

 Connected with managed MiniFiberLinX-II to the iMediaChassis/20 via fiber

3) WDM passive multiplexer

 Splitting SDH and Ethernet traffic

Railway Applications in Europe

4) Approval took 2 years testing on a big railway signaling company!

 Used in complete railway control centres, connecting with 2 fiber  Alcatel switch connections, spanning tree support by switch • •

Reliability Dual power supply

1 U high chassis

Successful extra EN testing: EN61000-6-2 (EMC) and EN61000-6-4 (EMC) 5) Multi-Platform of IMC

 Connect via fiber and copper Cat3 (Telephone) / Cat5  Single platform = Single Management

Railway Applications in Europe

6) AccessPoints / Hotspots on railway stations

 Outside installations  High temperature support for fiber connection & telephone Line!

7) IMC Networks product examples:

 IE-MiniMc  IE-MiniFiberLinX-II  IE-iMcV-VDSL2-LANextender  iMediaChassis/3,6,20  IE-iMcV-ModeConverter (SFP/SFP)

Fact

1) Everything is moving towards Ethernet / IP

Legacy / existing „old fashion“ installations need to be migrated 2) IMC Networks has the expertise to assist

Media and protocol conversion

Copper, Fiber based Installations

Managed, unmanaged deployments

System –level, standalone

Industrial Networking

Extended temperatures

• •

EMISSIONS: FCC Part 15 Subpart B Class A or B IMMUNITY: EN 61000-4-2: 1995 + A2: 2001 Electrostatic Discharge

SAFETY: UL 60950-1

Connecting Train Info Displays

RS485 Bus Systems

• Converted to Ethernet, IE-MiniFiberLinX-II  Small, high operating temperature range  Easy to install  Easy to manage

MiniMc – Miniature Media Converter

Low Cost, High Quality, Zero Intervention

• Switching technology to negotiate the copper link • Copper supports auto MDI/MDI-X • Fiber forced to 100Mbps • Full Duplex • Multi-mode, single-mode and single-strand fiber supported • External power supply

IP Cams - Surveillance

IP Cameras on railway stations connected

• Via fiber • Via copper • To the core network center *

Symbole Pictures

IMC applications - IE

IE-GigaMiniMc & IE-MiniMc What is IE?

• Multiple powering options  AC power  802.3af PoE  External DC, power range + 7VDC to 50VDC, overload protection • Supports extended operating temperature (eg IE-MiniMc -35 ° C to +70 ° C) • DIN-rail mount

Ticketing Systems, AccessPoints

*

Symbole Pictures

Industrial Ethernet Conversion

Different Power Connection Options: (Redundant)  802.3af-compliant powered device (PD)  5VDC (external DC-block)  External 5VDC to 60VDC  Built in sensor prevents overloading • DIN-rail mount • Supports operating temperature: -45 ° C to +70 ° C

Application Example

IE-Mini-FiberLinX-II

• City wide WiFi access network:  WiFi roaming & HD CCTV (traffic and security) • WiFi equipment from Cisco, mounted in custom lamp post • Cable run from head end to POP via

single-strand fiber (SSF)

• At head end IE-MiniFiberLinX-II:  Convert SSF to copper  Remote SNMP management  Large temperature range  Performance statistics  VLAN aware

• Our /20 chassis + iMcV FlinX-II + Mini-FlinX-II part of a turnkey solution BT OpenReach sells to BT and other telco’s  Top – Installation example from BT OpenReach handbook  Bottom – Street access NTE (inside this box is a Mini FlinX-II)

IE-Mini-FiberLinX-II

WDM Solution

SDH conversion – Splitting – to Gigabit & SDH

Operate SDH via fiber and migrate at the same time to Gigabit Ethernet Connectivity • Two fiber sources (1310 nm and 1550 nm) can be multiplexed onto a single fiber pair

Wavelength Division Multiplexing (WDM) Modules

• • • • Passive, 2-channel WDM  Technology “doubles” existing duplex fiber capacity Speed & protocol independent  Supports 1310 nm & 1550 nm SM fiber Ideal for combining legacy ATM circuits and Gigabit Ethernet over same fiber pair Two Versions  iMcV-WDM Module  Standalone WDM Chassis

WDM Chassis iMcV-WDM Module

iMediaChassis/6 – for sensitive connections !

Special Certifications

• • • • • • • • • • • •

ITEM TEST DESCRIPTION 1 Radiated Emissions, Class B EN 55011: 1998 + A2: 2003 2 Conducted Emissions, Class B EN 55011: 1998 + A2: 2003 3 EN 61000-4-2+A2: 2001 (Electrostatic Discharge Immunity) 4 EN 61000-4-3: 2002 (Radiated Electromagnetic Field Immunity) 5 EN 61000-4-4: 2004 (Electrical Fast Transient/ Burst Immunity) 6 EN 61000-4-5+A1: 2001 (Surge Immunity) 7 EN 61000-4-6+A1: 2001 (Conducted RF Immunity) 8 EN 61000-4-8+A1: 2001 (Magnetic Field Immunity) 9 EN 61000-4-11+A1: 2004 (Voltage Dips, Short Interrupts, & Variations) 10 EN 61000-3-2+A2: 2005 (Harmonic Current Emissions) 11 EN 61000-3-3+A1: 2001 (Voltage Variations & Flicker)

TEST RESULTS: IMC Networks’ iMediaChassis/6 with SNMP card, met all the requirements of EN61000-6-2 and EN61000-6-4 iMediaChassis/6 with SNMP Card

iMediaChassis/6 – for sensitive connections !

Special Certifications

• • • • • • • • • • • •

ITEM TEST DESCRIPTION 1 Radiated Emissions, Class B EN 55011: 1998 + A2: 2003 2 Conducted Emissions, Class B EN 55011: 1998 + A2: 2003 3 EN 61000-4-2+A2: 2001 (Electrostatic Discharge Immunity) 4 EN 61000-4-3: 2002 (Radiated Electromagnetic Field Immunity) 5 EN 61000-4-4: 2004 (Electrical Fast Transient/ Burst Immunity) 6 EN 61000-4-5+A1: 2001 (Surge Immunity) 7 EN 61000-4-6+A1: 2001 (Conducted RF Immunity) 8 EN 61000-4-8+A1: 2001 (Magnetic Field Immunity) 9 EN 61000-4-11+A1: 2004 (Voltage Dips, Short Interrupts, & Variations) 10 EN 61000-3-2+A2: 2005 (Harmonic Current Emissions) 11 EN 61000-3-3+A1: 2001 (Voltage Variations & Flicker)

TEST RESULTS: IMC Networks’ iMcV-LIM 10/100, met all the requirements of EN61000-6-2 and EN61000-6-4 iMcV-LIM 10/100 iMediaChassis/6 with SNMP Card

EFT

(electrically fast transient)

Immunity EN 61000-4-4 –

AC (Power Lines)

IMC Networks subjected to Railway Environment - like tests and PASSED

!

Surge Immunity EN 61000-4-5

Radiated Immunity EN 61000-4-3 – AC (Biconical Antenna - Vertical Plane) Radiated Immunity EN61000-4-3 – AC (Log Periodic Antenna - Horizontal Plane)

Product Details

Chassis, Module, HighTemp …

IE-Mini-FiberLinX-II

• • Smallest, managed converter device on the market!

Same specifications as iMcV-FiberLinX-II except:  Pure CPE device      • Standalone or with CO iMcV-FiberLinX-II No external management port Serial port via 3.5 mm audio jack (cable included) Power options: • External AC adapter • • POE – PD (Power over Ethernet) DC block 5-50 VDC External operating temperature range (-20 to +70 Celsius) DIN rail mount • Clip included

iMediaChassis/20, 20 slot

• • • • • • • • • • • • “i” means intelligent – i.e. managed 20-slots for Modules, 1-slot for SNMP All boards hot swappable  Settings ‘preserved’ when SNMP module is exchanged Supports SNMPv1 or SNMPv2c, and telnet capabilities Bigger hot-swappable power supply units (400W AC or 300W DC) Monitor fan speed and dual temperature zone Last Gasp Alarm Operational temperature up to 50°C

AC Input Load:

100 to 240 V AC±10%, 47-63Hz, 6.3A (Dual AC)

DC Input Load:

-38 to -72V DC, 11A Max (per module)

iMediaChassis/6, 6 slot

• • • • • • • • 6-Slot Managed Chassis  Available dual PSU  Support for six modules and SNMP board Targeted users:  More demanding environments  Telco grade solutions (NEBS-III pending) Compatible with ALL existing iMcV modules

AC Input Load:

100/240 V AC, 47-63Hz, 1.8A

115V @ 1.6A & 230 V @ 0.8A (single)

DC Input Load:

48 V DC, 3.3A

iMediaChassis/3, 3 slot

• 3-Slot Managed Chassis  Available dual PSU (AC, DC or mixed AC/DC)  Support THREE modules and SNMP board • Targeted users:  CPE applications  Applications needing SNMP, but a low module count • Compatible with ALL existing iMcV modules • AC Input Load: • • • 90 to 264 V AC, 47-440Hz

DC Input Load:

35 to 75 V DC, 2.7A

OverView of unmanaged Chassis

OverView of unmanaged Chassis

(IE) MediaChassis/1 and /2(AC and DC)

Module Overview

• • • • ‘Telco’ Protocols  E1 / E3 / OC3 / OC12 Ethernet protocols  10, 10/100 (L1 & L2), 100, Giga, 10/100/1000 (L2) Mode converters  MMF <-> SMF  10, 100, 155, 622 Mbps & Giga Manageable CO/CPE conversion  10/100, 10/100/1000 (FiberLinX family)

Module Overview

• All modules:  Available with ST-II (except Giga) or SC   SMF (1310 nm, 1550 nm), with various distances (40 / 80 / 120 km)  MMF (850 nm, 1300 nm) SSF, 20Km, 40Km 80Km • Including protocols and fiber there are 180+

modules available

The FiberLinX ‘Family’

• iMcV-FiberLinX-II • iMcV-Giga-FiberLinX-II • IE-Mini-FiberLinX-II

iMcV-FiberLinX-II

• 100Mbps manageable O/E conversion:  100Mbps fiber uplink  1 x 10/100 copper downlink  SFP versions available (TX/SFP and SFP/SFP)  Rate limiting  VLAN tagging • Offers trunking on downlink • • Also, “transparent” mode will pass any/all frame formats Full range VID • • 32 independent VLAN’s 802.1p available on each port • Two priority queues • SNMP Manageable from uplink only

iMcV-FiberLinX-II

• 100 Mbps manageable O/E conversion:  QinQ with configurable EtherType  Broadcast storm limitation (user definable)  IGMP (v2) pruning and snooping  Last gasp alert on board  Loopback (including MAC swap and IGMP clearance)

iMcV-FiberLinX-II versions

TX/1x9 TX/SFP SFP/SFP TX/TX

iMcV-Giga-FiberLinX-II

• 1,000 Mbps manageable O/E conversion  Functionality as per the 100 Mbps unit with the exception of:  1000Mbps fiber uplink  1x 10/100/1000 copper downlink  1x SFP “downlink” version also exists (LX to SX conversion)  Or SFP/SFP version

Access EtherLinX/4

• Multiport 100 Mbps termination  100 Mbps fiber uplink  4x 10/100 downlinks • Traffic can be isolated, or allowed to ‘mix’   Rate limiting on all ports (independent) VLAN tagging / trunking on all ports • Either ‘write’ a specific tag on traffic, or trunk a series of VLAN’s • Full range VID • • 16 independent VLAN’s 802.1p available on each port • Two priority queues  SNMP Manageable from uplink only   Broadcast storm limitation (user definable) IGMP (v2) pruning and snooping

Access EtherLinX/4 Application Diagram

Common features explained

• All FiberLinX-II and AccessEtherLinX share the following features:  Rate limiting  UMA capable • Remote management without IP  Q in Q¹, VLAN & 802.1p

1) AccessEtherLinX does not support QinQ

iMcV-Switch

iMcV-Switch

• • • • • iMcV module, multi-port switch  5 x 10/100 copper   4 X 10/100 copper and SFP 3 X 10/100 copper and 2 X SFP  3 X 10/100 copper and FX port model IE version available - operational temperature of -35c to +70c (note, use in conjunction with IE compliant SFP’s)

First release will be standard temp- range!

Can be managed via iView2 SNMP Element manager – (DDMI data, module inserted, powered) Diagnostic LED’s

Specifications

• Switching engine:  Supports up to 1000 MAC address earning and aging   Transparent to VLAN tags GUI and telnet port status from managed chassis only   Grants Priority for all frames with PRI>4 or DSCP > 32 Max packet size is 1916bytes • Physical:  Supports Auto Cross on all TX ports  Supports Auto Negotiate on all TX ports  Supports Flow Control on AN

Specifications (cont..)

• • • • No packet loss at 100% bandwidth throughput non-blocking port to port Priority queuing will support a 1 to 10 limitation All 512 internal buffers will be evenly divided between ports Per port buffers will be reserved for high priority frames

Specifications (cont..)

• Switch will not block VLAN tags • SNMP - can see module  Link status  Activity  Port status • Hard code speed/duplex via SNMP GUI or Telnet • No backplane communications required  Module is ‘standalone’, plug n play

Typical applications

• • Increase chassis efficiency, port density  Utilize spare chassis slots to provide 10/100 Ethernet switching Use in combination with iMcV-FiberLinX-II  Provide more customer ports while offering the FiberLinX functionality

Typical applications

• Increases port density of iMediaChassis/3-2AC • IE-iMcV-VDSL2-LANextender utilizes existing telephone cabling, connectivity between floors in the same building over a 100m range • iMcV-Switch, TX/4-SFP accommodates varying applications such as UDP video broadcast, data transmission, data access / archiving, and SNMP transmission at distance via the fiber port

IE-iMcV-ModeConverter

Promotion – Value Proposition

IE-iMcV-ModeConverter

For Network Operators and Service professionals Our SFP / SFP mode converter provides system – level diagnostics and troubleshooting with SNMP management, and enhanced user configured Link Loss in a modular form factor that easily integrates with existing systems, helping keep up with evolving transmission requirements such as distance or speed

Product – What is it?

IE-iMcV-ModeConverter

• Modular, compact iMcV form factor, supports any MSA – compliant SFP • SNMP Management and trap setting, including DDMI reporting • On board diagnostics and management, including front panel LED’s and enhanced Link Loss user selectable feature

IE-iMcV-ModeConverter

Product – What is it?

• • • • Protocol – independent SFP / SFP mode converter, supports multiple protocols:  Ethernet, Fast Ethernet  OC3, OC-12, OC-48 Supports multi-mode, single mode, dual and single fiber Supports speeds of 10 Mbps up to 2.4 Gbps Extended temperature range -40 ºC to +85 ºC for industrial applications

IE-iMcV-ModeConverter

Product – Benefits

Feature :

• SNMP Management and trap setting and DDMI reporting

Benefit:

• System - level monitoring, troubleshooting and diagnostics

IE-iMcV-ModeConverter

Product – Benefits

Feature:

• On board diagnostics, including front panel status LED’s and Link Loss (LL) user selectable feature  LL from SFP1 to SFP2  LL from SFP2 to SFP1  High/Low SFP speed selection • If LL not enabled a 25MHz “Keep Alive” signal is inserted in the line

Benefit:

• Immediate module diagnostic status, assist with troubleshooting and fault isolation at the CPE, CO or a POP along the network

Application – Industrial Environment

Application – Data Center

Application – Link Loss (LFPT)

Head End.

Mode – Link Loss = ON SDH ADM SFP1 (local) SD1 SFP2 (remote) SD2  Client End.

Mode – Link Loss = OFF/ON SFP1 (local) SD1 SFP2 (remote) SD2 Access Fibre - SFW Street Access TDM Variant

No Light

Comments:

LOS of RCV

on local BT fiber LoF, LoS SDH NTE

Application –Keep Alive (no LFPT)

Head End.

Mode – Link Loss = OFF SDH ADM SFP1 (local) SD1 SFP2 (remote) SD2  Client End.

Mode – Link Loss = OFF/ON SFP1 (local) SD1 SFP2 (remote) SD2 Access Fibre - SFW Street Access TDM Variant

25 MHz Signal

Comments:

LOS of RCV

on local BT fiber LoF, LoS SDH NTE

IE-iMcV-VDSL2 LANextender

Promotion – Value Proposition

iMcV-VDSL2-LANextender

For our customers, the IE-iMcV-VDSL2-LANextender delivers VDSL data rates at long and short ranges using existing phone grade wiring such as sub-standard CAT3 or other telephone cabling while auto adjusting the link quality (throughput) and monitoring and isolating faults with the Remote Alarm Indicator, Flow Control, and Link Fault Pass Through features

Product – What is it?

• Modular, compact iMcV form factor, one VDSL port with an RJ 11connector (VDSL) and one 10/100BaseT Ethernet port with an RJ-45 connector (DATA) • Provides 100 Mbps at greater than 100 m

iMcV-VDSL2-LANextender

• SNMP Management and trap setting (i.e., minimum Quality Level, etc.)

Product – What is it?

• Flow control detection, helps avoid dropping packets due to VDSL link congestion • Auto adjust to reach best bandwidth performance for the physical line used (maximum throughput) = LINK quality

iMcV-VDSL2-LANextender

• On board diagnostics and management, including front panel LED’s, Link Loss (VDSL or TX port), LFPT and Remote Alarm Indication

Product – Benefits

Feature:

VDSL2 performance at greater than 100 m

Benefit:

• 100 Mbps using existing phone grade wiring such as sub-standard CAT3 or other telephone cabling

iMcV-VDSL2-LANextender

• Customers want higher data rates (speed), we give them both, speed and distance

Product – Benefits

iMcV-VDSL2-LANextender Feature:

• Flow Control on the 10/100BaseT DATA interface • Indicator of VDSL2 link congestion • OVF LED (flashes)

Benefit:

• Alerts customer of potential network issue  Ethernet line is attempting to send more data than VDSL2 line can support (VDSL2 line provides less bandwidth than the DATA port configuration) • Helps stop discarding frames due to congestion

iMcV-VDSL2-LANextender

Product – Benefits

• •

Feature:

Auto adjust bandwidth performance, LINK quality Customer can config SNMP TRAP on minimum quality – level • • •

Benefit:

True plug –and – play operation Operating point AUTOMATICALLY maximizes bandwidth capability of the line in use LINK Quality displayed dynamically with LED’s via binary code

iMcV-VDSL2-LANextender

Product – Benefits

Feature:

LEDS •

Benefit: VDSL

RAI (Remote Alarm Indicator): When enabled, YELLOW when the unit at the far end has an alarm  FL (Fault Loopback): When enabled, unit will drop the DATA port link when VDSL port link is lost: ENABLED = ACTIVATED = (flashing)  LOS (Loss of Signal): when enabled, LED is RED if VDSL port is down  ER (Error): When enabled, YELLOW if:  Symbol error  VDSL Bandwidth below user defined

iMcV-VDSL2-LANextender

Product – Benefits

Feature:

LEDS • •

Benefit: LINK QUALITY 8-4-2-1

 GREEN LED’s form a “binary” code, indicating maximum bandwidth VDSL line can support

DATA

OVF (Overflow): When enabled, LED flashes YELLOW when frames are lost due to VDSL congestion  LFPT: When enabled LED is GREEN and flashes if LOS of the far end TX line  LOS (Loss of Signal): when enabled, LED is RED if VDSL / DATA port is down  ER (Error): When enabled, YELLOW when DATA port receives a symbol error

Conclusion

Improved VDSL LANextender Performance

• True 100Mbps at short range and long range

iMcV-VDSL2-LANextender

• Quality control and operation, including flow control and automatic maximum throughput configuration and operation • Improved Fault detection, including packet loss detection and notification, and the availability of RAI and LFPT

Rate verses Reach

VDSL2 Bandwidth / Distance

100000 10000 1000 100 0 1000 2000 3000 4000

Feet

5000 6000 7000 8000 9000 10Pass-TS 2Base-TL EtherWan Patton 997 IMC Down 997 IMC UP OLD VDSL

Band Plan 998 and 997

997 and 998 With ISDN

100000 10000 1000 100 0 1000 2000 3000 4000 5000

Distance (Feet)

6000 7000 8000 9000 997 US Line Rate 997 DS Line Rate 998 US Line Rate 998 DS Line Rate

Open Discussion

Except SFPs – only 1 year > > > > Questions?

Current projects Current favorite Products Wishes?

Thank you!

• contact information:

SALES SUPPORT:

Heike Saadatpour [email protected]

Tel.: (+43) 676 470 70 50

TECHNICAL SUPPORT:

Jan De Smedt [email protected]

Brendan Mullooly [email protected]

Tel.: (+32) 16-550880

http://www.imcnetworks.com

datasheets, White Papers Technical/Case Studies,...

Product Finder, aam