Gasfuse™ South Africa

Download Report

Transcript Gasfuse™ South Africa

Gasfuse™ South Africa
Business Overview
GasFuse™ South Africa Ltd is the appointed Key Master Distributor of GasFuse™ for and on behalf of
Premier Fosters Australia Pty Ltd for Southern Africa.
Moreover, Premier Fosters Australia Pty Ltd have met all the Australian Gas Association procedures and
compliance to ensure conformance to the regulations and standards of the Australian Gas Association,
Australian Gas Association Approval Number 6127, Patent No.597625.
GasFuse™ South Africa Ltd, is a Company, located within Gauteng, South Africa. The Core Nature of the
Business is to Import, Supply & Distribute Sophisticated Liquid Petroleum Gas Safety Equipment.
An official Business Module outlining Products and Services to be supplied and distributed will be
promoted by GasFuse™ South Africa Ltd to prospective and existing Channel Partners. Marketing material
and/or electronic format brochures as well as intellectual features and functions of GasFuse™ are
accessible on our Worldwide Webpage to approved Channel Partner/s.
GasFuse™ South Africa Ltd offers you an opportunity to diversify your services and products, increase your
market share and expand your operations even further by marketing our exclusive GasFuse™ LPG Safety
Product.
Sequence of normal Gas Flow
The Sequence of Normal Gas Flow
Gas enters the Gasfuse directly from the cylinder;
Gas is channeled into a chamber, where it passes the shutoff element;
Gas is then channeled up out of the chamber and past the gauge pin;
Gas then exits;
The various uses of Gasfuse all follow from this sequence.
Importantly, the gauge pin is directly attached to the gauge, and acts as a pressure detector, which
causes the gauge to show changes in gas pressure via movement in the needle.
Gasfuse™ Principle Functions
How Gasfuse™ Stops Major Leaks
The shutoff mechanism works on the Bernouilli effect. A sudden increase in gas flow (for example from
the hose rupturing) changes the pressure around the shut off element, lifting it up and causing it to plug
the exit to the chamber and stop the flow of gas completely.
The shutoff element will stay in this position until you push down on the gauge. The gauge pin then
pushes the shutoff element back down into the chamber, so resetting the Gasfuse ready for normal
operation.
How Gasfuse™ Detects Small Leaks
By turning the cylinder on and the appliance off, you allow gas to fill the Gasfuse, gas hose and all gas
pipes and manifolds, all the way up to the appliance.
When you turn the gas cylinder off, the gas should stay in the Gasfuse, hose and inside the appliance. If
there is any leak, the pressure should drop because gas is escaping but not being replenished (because the
cylinder is off).
The drop in pressure will be detected by the gauge pin, causing the needle to move downwards.
How Gasfuse™ Tells You That You're Low On Gas
The gauge detects pressure through the gauge pin. When gas in the cylinder is low, the pressure drops
and the needle falls towards the red section of the gauge.
Gasfuse™ Gas Safety Standards
Australian Standard AS4557-2004
By law, all new barbecues sold in Australia must have a device fitted which either shuts off or limits the flow
of gas.. (Implementation date 1 January 2005, clause 2.4.1.2).
The actual wording of the clause is:
Means to automatically shut off or reduce gas flow that will operate at a flow of not more than 3.0 cu.m/hr
(air equivalent at standard conditions) with 700 kPa supplied to the inlet of the device.
In the case of a device that reduces the flow of gas, the bypass shall not allow a flow greater than 0.3 m3/h
(air equivalent at standard conditions) with 700 kPa supplied to the inlet of the device.
The means shall(a) be integral with the regulator assembly;
(b) be designed in a way to prevent consumer disassembly without the use of specialized tools or undue force;
and
(c) include either manual or automatic reset without the need to disconnect any part of the gas piping system,
including the cylinder connection.
This clause recognises that gas safety is a more serious issue now than any time in the past. Gasfuse
does more than meet the minimum requirement of the standard. It meets or exceeds the most most
stringent requirement for total shutoff. The exact implementation date of this clause is under review.
AGA Certificate
Geneve International Diploma
Underwriters Laboratory Report
Gasfuse™ South Africa
Thank you
We believe that a type of transaction/partnership between us would be mutually beneficial and fruitful.
Your company has already tapped the local resident market and has its own Clientéle market share.
GasFuse™ South Africa Ltd offers you an opportunity to diversify your services and products, increase your
market share and expand your operations even further by marketing our exclusive GasFuse™ LPG Safety
Product.
We look forward to our future collaboration and please do not hesitate to contact us if you need any
additional information or have any queries.
Respectfully;
Keith Verster
Mobile:- +27 078-055-9330
Email:- [email protected]
Webpage:- www.gasfusesa.co.za
For and on behalf of GasFuse™
South Africa Ltd