Transcript Document
Flight 60 The Most Versatile Autonomous Ventilator Confidential 1 Well known technology in an intuitive and advanced ventilator Performance • Volume Guarantee, Weaning mode • Bi-Phasic Ventilation (APRV) • Unlimited autonomy: 12 Hours battery life, 15lbs Confidential 2 Well known technology in an intuitive and advanced ventilator Versatility • • • • Confidential Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive 3 Well known technology in an intuitive and advanced ventilator Simplicity • • • High resolution 7” touch screen Ease of use/ All functions on one screen Waveforms, loops and 72 Hours trends Confidential 4 Well known technology in an intuitive and advanced ventilator Performance • Volume Guarantee, Weaning mode • Bi-Phasic Ventilation (APRV) • Unlimited autonomy: 12 Hours battery life, 15lbs Versatility • Paediatric to Adults • Dual/Single limb • High Pressure & Low Flow Oxygen Simplicity • Invasive and non invasive • High resolution 7” touch screen • Ease of use/ All functions on one screen • Waveforms, loops and 72 Hours trends Confidential 5 99% Success, meet all clinical needs Trauma Lung Cancer COPD Spinal Cord Injury ARDS Neuromuscular Pulmonary Edema ALS Confidential 6 Flight 60 – Unique Features for Transport, Sub-Acute, ED, LTAC, Home Care & ICU* (*emerging markets) Confidential 7 Advanced Modes MVG Bi-Level/APRV PRVC Advanced Monitoring Extended Versatility Dual Limb Model Lung Mechanics Supreme Safety Hospital Standard Exhaled Volume Monitoring Internal Blender Compact and Easy to Use Bright Display Loops & Waveforms 15lbs Confidential 8 Flight 60 – Meets the Need Sub-Acute In-Hospital Transport Long Term Home Care • Quick-Start • VCV from 30ml to 2,200 • All modes • Waveforms and Loop • APRV (transport ARDS patients , maintain ICU settings) • Internal Blender (durability) • Quick-Start • Lightweight 15lbs • Advanced Modes • Dual Limb • Internal Blender • Lung Mechanics • 12 Hours battery • Telemedicine ready • Integrated O2 sensor with in-use calibration • Volume Guarantee Confidential 9 Market Segment Sub-Acute Transport Flight 60 Vela + + + Trilogy Hamilton Philips 100/20 HT70+ C2 V60 0 + + Acute Care NIV Long Term Home Care ICU (emerging markets) + + + + + + + + + + + 10 Flight 60 – Unique Weaning Mode 1/3 Volume Guarantee Mode Improves patient ventilation and safety by adjusting to changes in: • Progression of the disease • Body position and sleep stages • Best of volume control ventilation and pressure control ventilation. Confidential 11 Flight 60 – Unique Weaning Mode 2/3 MVG – Minute Volume Guarantee MVG = Volume Guarantee + Back-up rate • Improved Patient Comfort • Adaptive PSV (Lower PIP for equal Volume) • Better Weaning (automatically switches to spontaneous breathing) Confidential 12 Flight 60 – Unique Weaning Mode 3/3 Unique Trigger Delay function • Encourages spontaneous breathes • Eliminates frequent switching between patient triggered/time triggered breathes • Improved weaning & enhanced patient synchronization Confidential 13 MVG Improves Patient Comfort Case Report • Patient and history: – A 48 year old man with history of Crohn’s disease and epilepsy was admitted with pleuritic chest pain and food aspiration. Patient was sedated and orally intubated. • Initial vent Settings: – Mode: SIMV-PC, PC = 15cmH2O, PEEP = 7cmH2O • MVG Setting: – Mode: MVG, Target Volume = 400ml, PEEP = 7cmH2O Confidential 14 MVG Improves Patient Comfort Case Report Phase 1: SIMV Mode Phase 1: MVG Mode PIP = 27cmH2O Vt = 454ml PIP = 17cmH2O Vt = 437ml MVG is able to track the patient’s change in respiratory mechanics and adjust pressure accordingly. Confidential 15 Flight 60 – Flight 60 –Low maintenance and Reliability • • • Install base of over 2000 in 3 years Only Manifold and O2 sensor are replaced on preventive maintenance Manifold PM is at 15,000 working hours Confidential 16 1500 beds, 40 F60s, 100% satisfaction Leading acute care university hospital • • • • • Successfully integrated into 10 sub-acute wards Adapted by ER staff as main ventilator In-hospital transport – Only Flight 60 Replaced Vela and iVent201 3 Years of experience Confidential 17 Active mobilization with Flight 60 Bedside: PB840 Transport: Flight 60 • “...it’s the smallest that they make but at the same time the electronics allow us to do all of the types of therapy we do with a full size ventilator…” Stephen Holland, M.D. Vice President and Chief Medical Officer Confidential 18 www.flight-medical.com