ANSI CP-01 Standards

Download Report

Transcript ANSI CP-01 Standards

ANSI SIA CP-01
CONTROL PANEL STANDARDS
COMBATING ALARM
DISPATCHES
ALL ASSOCIATIONS
PARTICIPATED

AIREF
Alarm Industry Research & Education Foundation

CSAA
Central Station Alarm Association

NBFAA
National Burglar & Fire Alarm Association

SIA
Security Industry Association

CANASA Canadian Alarm Security Association
UL COMPLIANT







UL 609 - Local Burglar Alarm
UL 611 & 1610- Central Station BA
UL 684 - Mercantile & Bank
UL 864 - Fire Protective Signals
UL 985 & 1023 - Household Fire, BA
UL 1635 - Digital BA Communicators
UL 1641 - Residential Systems
WHY NEW STANDARDS?

Meeting of Industry Professionals...
Need for further reductions...
 Need for standardization...
 Based on known solutions...
 Based on HIGH user error...

MOST Panel Manufacturers Participated!
False Dispatch Elimination

Most User Errors - During Entry/Exit:





User Arms - Exits - Re-enters…
User Arms - Fails to Exit in time…
User Arms - Building still Occupied…
User Arms - Exits Through Wrong Door…
User Arms - Fails to exit at all...
False Dispatch Elimination

Most User Errors - During Entry/Exit:

User enters - forgets code…
User enters - fails to disarm within delay time…
User enters - unfamiliar with system...

User enters - through the wrong door…



non-delayed

no keypad - unable to hear prewarn
New Control Panel Standards

Exit Delay:

Default - 60 seconds (Min 45 sec)

Progress Annunciation - different sound the last
10 seconds of delay

AUTOMATIC RESTART of exit delay, ONCE!
(upon re-entry)

Recent Closing - signal sent if alarm within 2
minutes of Exit time expiration
New Control Panel Standards

Exit Delay:

Fail to exit - arms all zones STAY MODE

Remote annunciation supported by panel

Exit Time DOUBLED if user disables pre-warning.
(dealer cannot disable globally)

Exit Error - Immediate local alarm...
New Control Panel Standards

Entry Delay:

Default 30 seconds (Minimum 30 sec)

Progress Annunciation - different sound last ten
seconds of delay
Pre-Warning Silenced - after 1st digit code entry
Cancel Message window after abort window - 5
minutes


ALL BURG ZONES… “ABORT WINDOW”



Burglary - default 30 sec* (15-45 range)
Fire - default No delay
Hold-up/Tamper - No delay
*May disable by zone or zone type!
LOCAL ALARM STILL SOUNDS - ONLY
COMMUNICATION IS DELAYED
New Control Panel Standards

Wireless/Remote accommodations
 Inadvertent activation's - Minimized
(No “Single Action” buttons… Hold-up, Panic, Fire, Etc)
System Acknowledgement - Exterior
 Option to eliminate: (default - on)

Exit Time Delay
 “Stay Mode” upon failure to exit

New Control Panel Standards

Other New Features:


Upon Power Restoral 60 second settling out
period.. NO ALARM SIGNALS TRANSMITTED!
Swinger shut-down - default - “1” (MAX-2)



Will reset after 48 hours - with no trips
NEW (OPTIONAL)- Swinger Trouble signal sent after 1st
trip
Universal disarming sequence - code only
New Control Panel Standards

Other New Features:






Cross Zoning features available
1+ duress Eliminated!
*70 Call Waiting - 2nd Call Option…
Test in Progress Features
Preset Automatic Arming - Audible !
New “Simple” Instruction Card!
New Standards & UL
UL - Testing to the new standards...
 New UL sticker on panels...

LISTED
DESIGN EVALUATED BY UL IN ACCORDANCE WITH
Panel Standard
SIA CP-01 Control
- Features for False Alarm Reduction
What YOU can do...

Verification Call - always…

Customer Training - continuously..




Simplified operating instructions
Written monitoring procedure
Videos - Tips on reductions
Billing/Newsletter reminders
What you can do...

In House Employee Training
 Pro-Active Approach (Set-up Team)




Use new standards on existing panels
Call customers within 24 hours of event
Service promptly!
Target 10 Worst Offenders Monthly


Use Central Station Software to Track!
Be an ACTIVE Member of the Local, State
and National Associations