ANSI SIA CP-01
CONTROL PANEL STANDARDS
COMBATING ALARM
DISPATCHES
ALL ASSOCIATIONS
PARTICIPATED
AIREF
Alarm Industry Research & Education Foundation
CSAA
Central Station Alarm Association
NBFAA
National Burglar & Fire Alarm Association
SIA
Security Industry Association
CANASA Canadian Alarm Security Association
UL COMPLIANT
UL 609 - Local Burglar Alarm
UL 611 & 1610- Central Station BA
UL 684 - Mercantile & Bank
UL 864 - Fire Protective Signals
UL 985 & 1023 - Household Fire, BA
UL 1635 - Digital BA Communicators
UL 1641 - Residential Systems
WHY NEW STANDARDS?
Meeting of Industry Professionals...
Need for further reductions...
Need for standardization...
Based on known solutions...
Based on HIGH user error...
MOST Panel Manufacturers Participated!
False Dispatch Elimination
Most User Errors - During Entry/Exit:
User Arms - Exits - Re-enters…
User Arms - Fails to Exit in time…
User Arms - Building still Occupied…
User Arms - Exits Through Wrong Door…
User Arms - Fails to exit at all...
False Dispatch Elimination
Most User Errors - During Entry/Exit:
User enters - forgets code…
User enters - fails to disarm within delay time…
User enters - unfamiliar with system...
User enters - through the wrong door…
non-delayed
no keypad - unable to hear prewarn
New Control Panel Standards
Exit Delay:
Default - 60 seconds (Min 45 sec)
Progress Annunciation - different sound the last
10 seconds of delay
AUTOMATIC RESTART of exit delay, ONCE!
(upon re-entry)
Recent Closing - signal sent if alarm within 2
minutes of Exit time expiration
New Control Panel Standards
Exit Delay:
Fail to exit - arms all zones STAY MODE
Remote annunciation supported by panel
Exit Time DOUBLED if user disables pre-warning.
(dealer cannot disable globally)
Exit Error - Immediate local alarm...
New Control Panel Standards
Entry Delay:
Default 30 seconds (Minimum 30 sec)
Progress Annunciation - different sound last ten
seconds of delay
Pre-Warning Silenced - after 1st digit code entry
Cancel Message window after abort window - 5
minutes
ALL BURG ZONES… “ABORT WINDOW”
Burglary - default 30 sec* (15-45 range)
Fire - default No delay
Hold-up/Tamper - No delay
*May disable by zone or zone type!
LOCAL ALARM STILL SOUNDS - ONLY
COMMUNICATION IS DELAYED
New Control Panel Standards
Wireless/Remote accommodations
Inadvertent activation's - Minimized
(No “Single Action” buttons… Hold-up, Panic, Fire, Etc)
System Acknowledgement - Exterior
Option to eliminate: (default - on)
Exit Time Delay
“Stay Mode” upon failure to exit
New Control Panel Standards
Other New Features:
Upon Power Restoral 60 second settling out
period.. NO ALARM SIGNALS TRANSMITTED!
Swinger shut-down - default - “1” (MAX-2)
Will reset after 48 hours - with no trips
NEW (OPTIONAL)- Swinger Trouble signal sent after 1st
trip
Universal disarming sequence - code only
New Control Panel Standards
Other New Features:
Cross Zoning features available
1+ duress Eliminated!
*70 Call Waiting - 2nd Call Option…
Test in Progress Features
Preset Automatic Arming - Audible !
New “Simple” Instruction Card!
New Standards & UL
UL - Testing to the new standards...
New UL sticker on panels...
LISTED
DESIGN EVALUATED BY UL IN ACCORDANCE WITH
Panel Standard
SIA CP-01 Control
- Features for False Alarm Reduction
What YOU can do...
Verification Call - always…
Customer Training - continuously..
Simplified operating instructions
Written monitoring procedure
Videos - Tips on reductions
Billing/Newsletter reminders
What you can do...
In House Employee Training
Pro-Active Approach (Set-up Team)
Use new standards on existing panels
Call customers within 24 hours of event
Service promptly!
Target 10 Worst Offenders Monthly
Use Central Station Software to Track!
Be an ACTIVE Member of the Local, State
and National Associations