Transcript Document

Visual checking of Muon Reconstruction using Atlantis
Gary Taylor (UCSC) 1/4/2003
Atlantis
• General purpose interactive event display program
• Concentrate here on its application to muon track reconstruction
Outline
•
•
•
•
•
•
MDT, RPC, TGC, CSC Digits
Moore tracks
Matching muon tracks to inner detector tracks
Future plans
Conclusions
Short demonstration
130 GeV Higgs decaying to 4 muons (all reconstructed by Moore)
RPC
TGC
MDT unassociated
MDT associated
1 TeV Pt Muon reconstucted in the barrel region
RPC
Moore tracks
not yet followed
in B field
MDT
associated
MDT
unassociated
1 TeV Pt Muon reconstucted in the endcap region
MDT
TGC
space
points
MDT hits
not long
enough
TGC
strips
1 TeV Pt muon reconstructed with 2.5GeV Pt – Why?
MDT hits on
Moore track
Unused
MDT hits near
true track
1 TeV m
CSC hits
on
Moore
track
1 TeV Pt muon not reconstructed – Why?
MDT hits
too short ?
130 GeV Higgs decaying to 4 muons (only 2 reconstructed by Moore)
2 muons (Pt = 24 and 35 GeV)
Some minor bugs found in the geometry
7/BIL/-1/5/MDT/2/3/13
Comparison of muon and inner detector track fits
f
p = 28 GeV
Dp = 5 GeV
Df = 1.5 deg
Dh = 0.02
muon
tracks
Inner detector
tracks
p = 25 GeV
Dp = 4 GeV
Df = 1 deg
Dh = 0.01
V-Plot allows comparison
of f, h and pt
h
Near term future plans (muon data)
• follow Moore tracks in B field
• follow true (kine) muon tracks in B field
• add true (kine) track-to-hit association
• add data from CSC’s clusters
• change to use compact identifiers
Conclusions
• many aspects of muon reconstruction may be checked using Atlantis
• remaining muon data available soon (when in Athena)
• followed by new public release
• users and their feedback/requests are very welcome
• to learn more - sign up for Atlantis tutorial on Friday 16th May
(next software week)
Special thanks to
• Hans Drevermann (Ideas and advice)
• Jon Couchman (Access to data from Athena –JiveXML)
Explanation of the fh and V-Plot projections
f
r = rMax
V-Plot
Draw each space point
twice at
F,h+k*(r-rMax)
and
F,h-k*(r-rMax)
r = 2 cm
h
low p, -ve
Distorted V’s
track not from IP
high p, +ve
 3D information
For tracks can judge
•f
•h
• pt (slope of V arms)
• charge ( L -ve
V +ve)