maccor - (주)한국써모테크(KOREA THRMO

Download Report

Transcript maccor - (주)한국써모테크(KOREA THRMO

Welcome to our World of
Energy Storage Device
Test Systems
Who is Maccor ?
Maccor specializes in the design and manufacture of
high performance test systems for batteries, fuel cells
and supercapacitors.
 First test system built in 1983.
 Largest, most experienced company worldwide, for
the testing of small batteries of all chemistries.
 Head office and primary manufacturing facilities in
Tulsa, Oklahoma, USA.
 Approximately 100 people and US$12 million in
sales per year, with representation in many countries.

What Does Maccor Equipment Do ?
 Maccor
equipment is used to determine the
quality and performance of various energy
storage devices by applying simulated loads
under computer control.
This is achieved with synchronization of
control and measurement, and with a high
level of accuracy.
Typical Tests Performed
Cycle Testing under Constant Current, Constant
Voltage, Constant Power, Constant Resistance loads.
 Pulse Discharge Tests such as GSM, CDMA,
Multiple Slot and Multiple Current level.
 Cyclic Voltametry.
 AC Impedance measurements.
 Frequency Response Analysis.
 Formation of Lithium Cells.

Applications
 Materials
Research.
 Product Development.
 Product Manufacturing.
 Quality Control.
 Product Qualification.
 Cell Sorting.
 Application Testing.
Why Purchase a Maccor System?

Quality:
proven by the long term reliability of all
Maccor systems in use today.

Features:
the most comprehensive set of features with
upgrades to address new applications.

Performance: highest accuracy, speed, reliability and
capabilities of any system.

Support:
considered by our customers as the best in
the industry.

Experience:
unequalled, resulting from many years of
work with numerous applications worldwide.
Products

Series 4000, Model 2300, Model MC4,
Secondary Battery Test Systems.

Series 3500 and Series 3600
Primary Cell Test Systems.

Series 5300 Lithium Cell Formation System.

Model EDA Frequency Response Analyzer.

Series 6000 Fuel Cell Test System.
General Specifications (1)
General Specifications (2)
Typical System Functions
The following screens provide examples of
test procedures and results achieved for a
number of standard experiments.
Long Term Cycle Test
Charge Profile Nickel Vs Lithium
CC / CV Charge Lithium Ion Battery
4.3
4.1
CC Charge for NiMH Battery
Constant Current
0.8
0.9
1
1.1
1.2
1.3
Time/h
1.4
1.5
1.6
1.7
V of NiMHCYC5.0014
I of NiMHCYC5.001
3.9
Voltage/V
3.8
Constant Current
3.7
3.6
Current Tapered
3.5
3.4
3.3
3.2
67.5
68
Time/h
68.5
69
V of Ltcycle2.002
I of Ltcycle2.002
Current/mA
Time End Condition
560
540
520
500
480
460
440
420
400
380
360
340
320
300
280
260
240
220
200
180
Current/mA
1.48
1.47
1.46
1.45
1.44
1.43
1.42
1.41
1.4
1.39
1.38
1.37
1.36
1.35
1.34
1.33
1.32
1.31
1.3
1.29
480
460
440
420
400
380
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
Constant Voltage
4.2
Charge NiMH Cell
with –dV Termination
Voltage/V
End of Charge
1.506
1.506
1.506
1.505
1.505
1.504
1.504
1.503
1.503
1.502
1.502
1.501
1.501
1.5
1.5
1.499
1.499
1.498
1.498
1.497
1.497
1.496
1.496
1.495
V of Dv1.006
Peak Voltage
Charge Terminated
11.7
11.75
11.8
11.85
Time/h
11.9
11.95
GSM Pulse Discharge Test
GSM Pulse Discharge
4.2
V of DEMO_GSMPLI02.002
4.1
Pulse Low
4
3.9
Voltage/V
3.8
3.7
3.6
3.5
3.4
Pulse High
3.3
3.2
3.1
3
7.2
7.4
7.6
7.8
8
8.2
8.4 8.6
Time/h
8.8
9
9.2
9.4
9.6
Multi-Slot and Multi-Level Pulses
Cyclic Voltametry
Cyclic Voltagram 10 Cycles NiMH
I of ScanNiMH04.002
Voltage Scan 10 mV / S
1.4
2
V of ScanNiMH04.002
I of ScanNiMH04.002
1.38
1.36
3
1.34
1
1.32
1.3
1.28
0
2
Current/A
Voltage/V
1.24
1.22
1.2
1.18
-1
1.16
1.14
1.12
-2
1
1.1
1.08
1.06
-3
1.04
1.02
1
50
1
0
60
70
80
Time/min
90
100
1.05
1.1
1.15
1.2
Voltage/V
1.25
1.3
1.35
1.4
Current/A
1.26
AC Impedance
Data Analysis
yticapaC .sV egatloV egrahcsiD
00.92
00.82
00.72
00.62
00.42
00.32
00.22
00.12
00.02
000,21
000,01
000,8
000,6
000,4
hAm/yticapaC
.CNI ,ROCCAM
000,2
0
V/egatloV
00.52
Frequency Response Analysis 1
Frequency Response Analysis 2
Formation, Single Cell Data File
End of Formation Report
Sales and Service






Available in many countries.
Technical advice on the best
system for your needs.
Assistance with your
application.
System commissioning.
Operator and maintenance
training.
Free after sales telephone/fax/
e-mail support for the
life of the product.
For Sales and Service Contact
USA / Canada:
Korea:
Maccor Inc.
Korea Thermo-Tech, Inc.
Phone: + 918-446-1874
Fax:
+ 918-445-1496
Email: [email protected]
Phone: + 82-2-431-1491
Fax: + 82-2-431-1494
Email: [email protected]
Singapore:
China:
Achema Pte Ltd
Smart Technology Ltd.
Phone: + 65-356-9081
Fax: + 65-356-9082
Email: [email protected]
Phone: + 86-10-6831-6810
Fax:
+ 86-10-6831-6760
Email: [email protected]
Europe:
Israel:
BMMS Ltd.
WeisScientific Ltd.
Phone: + 44-1858-46-8438
Fax: + 44-1858-46-8439
Email: [email protected]
Phone: + 972-396-69391
Fax: + 972-396-56781
Email: [email protected]
Taiwan:
India:
Formosa EMV Techrico Corp.
Con-Serv Enterprises
Phone: + 886-4-2230-1212
Fax: + 886-4-2236-3848
Email: [email protected]
Phone: + 91-22-5913743
Fax: + 91-22-5913743
Email: [email protected]
Summary
The equipment, features, and capabilities of
Maccor, extend beyond that described above.
For further information or assistance with
your application, please contact Maccor direct
or one of our international representatives.
Thank you for taking the time to view this
presentation.