Transcript Slide 1

FLEX 100H
Heat Recovery Ventilators
Flexibility in Perfect Form.
WHOLE BUILDING VENTILATION
ASHRAE 62.2 - 2010, Table 4.1a
Minimum Ventilation Air Requirements, CFM, New Buildings
FLOOR AREA
(FT2)
BEDROOMS
0-1
2-3
4-5
6-7
>7
<1500
30
45
60
75
90
1501-3000
45
60
75
90
105
3001-4500
60
75
90
105
120
4501-6000
75
90
105
120
135
6001-7500
90
105
120
135
150
>7500
105
120
135
150
165
SPOT VENTILATION
ASHRAE 62.2 - 2010
» Local exhaust fans must be installed in bathrooms or kitchen
» Bathrooms
» 50 CFM on-demand, or
» 20 CFM continuous
» Kitchen
» 100 CFM on-demand*, or
» 5 ACH, based on kitchen volume
» 12’ x 14’ x 7.5’ kitchen requires 105 CFM
*Vented range hood required if exhaust fan flow rate is less than
5 kitchen air changes per hour.
VENTILATION OPTIONS
» ASHRAE 62.2 - 2010 (912 sq.ft, 3 bedroom, 1 bath, kitchen)
OPTION 1:
» Whole building mechanical ventilation
= 40 cfm
» Spot Exhaust bathroom ventilation
= 1 x 20 cfm continuous for bathrooms
» Balanced Continuous = 40 cfm supply,
40 cfm exhaust (Dedicated kitchen exhaust)
OPTION 2:
» Whole building mechanical ventilation = 40 cfm
» Spot Exhaust mechanical ventilation = 50 cfm (1 x 50 cfm intermittent bathroom)
» Spot Exhaust Kitchen Ventilation = 100 cfm
» Balanced Continuous = 40 cfm supply, 40 cfm exhaust
» Spot Exhaust = 150 cfm (50 cfm bathroom + 100 cfm kitchen)
VENTILATION OPTIONS
» ASHRAE 62.2 -2010 (900 sq.ft, 2 bedroom, 2 bath, kitchen);
OPTION 1:
» Whole building mechanical ventilation = 30 cfm
» Spot Exhaust bathroom ventilation = 2 x 20 cfm
continuous for bathrooms
» Balanced Continuous = 40 cfm supply, 40 cfm
exhaust (Dedicated kitchen exhaust)
OPTION 2:
» Whole building mechanical ventilation = 30 cfm
» Spot Exhaust mechanical ventilation = 40 cfm
(2 x 20 cfm continuous bathroom)
» Spot Exhaust Kitchen Ventilation = 100 cfm (intermittent)
» Balanced Continuous = 40 cfm supply, 40 cfm exhaust
» Spot Exhaust = 140 cfm
Introducing the
FLEX 100H
THE REST OF THE PACK
Fantech
FLEX 100H
Venmar
VanEE
Constructo 1.0
60H
Lifebreath
RNC 85-TFP
RNC-120D
Greentek
SS 3.12
FLEX Features
Accurate Measuring
Aluminum Core
Provides superior heat transfer
capability in a small package
Turbo Touch
The Turbo Touch feature delivers
up to 50% more exhaust capacity
Patented integrated airflow measurement
system allows for rapid and accurate reading of
airflow and eliminates the need for an external
flow meter
Quick Connect
Removable quick connect terminals
provide easy & convenient electrical
connection
Simple Installation
The durable EZ-Mount wall bracket
allows for an effortless, one-person
installation
FLEX Features
Convenient Access
Top-mounted ports with unobstructed front
access allow for easier duct connectivity
Powerful Package
10% smaller than comparable units and
5% lighter than the other brands while
providing up to 50% more exhaust
capacity
Winter Guard
Built-in defrost system provides smooth, reliable
operation even during the harshest winters
Easy Maintenance
All serviceable internal components can
be fully removed in under 5 minutes
FLEX Benefits
Flexible
Ideal for multi-family
Fits almost anywhere
Compact
Smallest HRV in
its category
Advanced
Latest German,
factory-balanced EBM
¨Radical¨ fans
Quiet
New technology reduces
noise and operating costs
Lightweight
5% lighter than
comparable units
Powerful
TurboTouchTM provides
up to 50% more exhaust
capacity
Quick to Install
Includes EZ-MountTM
wall bracket
Reliable
Best all-around warranty
in industry
FLEX Specs
MARKETING Support