Transcript Document

• WAC 296.305 Safety Standards
for Firefighters
• NFPA 1407 Standard for Training
Fire Service Rapid Intervention
Crews, 2010 edition
• Snohomish County Fire Chiefs
Incident Management System
Policies
The RIC procedure was developed by the Snohomish County Training Officers (SCTO). Input was received from numerous Snohomish County Fire Agencies to
create a document that would be universal throughout Snohomish County.
SCTO understands that each department may need to make changes to this procedure to “work” for each agency.
Our goal is to keep the procedure intact to ensure all companies operating on an incident understand each others tactical operations.
• C.A.N Report
• Conditions
• Actions
• Needs
UCAN and CANA are other variations of the more popular CAN report. UCAN is stating your unit identification. CANA is a
report of your air after the conditions , actions and needs.
• IDLH (Immediately Dangerous to Life and Health.
• Defines in WAC 296-62-07105 as “an atmosphere that poses a threat to life,
would cause irreversible adverse health effects or would impair an individuals
ability to escape from a dangerous atmosphere.”
• Incipient Fire
• A fire which is in the initial stage and which can be controlled or extinguished
by a portable fire extinguisher, class II standpipe or small hose systems.
• Initial Stages of an incident
• Includes the period of an incident when tasks are being undertaken by the
first arriving companies with only one team assigned or operating within the
IDLH.
• Mayday
• The term used when a firefighter(s) needs immediate assistance.
• Softening the Building
• Proactive measure taken by a RIC members at the direction of the RIC Group
Supervisor (RGS) to assure that egress route are established prior to any
potential firefighter emergency.
• Before making any opening that could affect the ventilation profile the RGS
must receive approval from the Incident Commander.
• Rapid Intervention Crew (RIC)
• A dedicated crew of firefighters who are assigned for rapid deployment to
rescue lost or trapped firefighters. It is highly recommended that a
minimum of three firefighters be assigned to RIC.
• Standby Firefighters
• Refers to the firefighters who are assigned to standby outside the IDLH area
ready to respond to a firefighters emergency. Standby firefighters can be
assigned other tasks while standing by. Standby firefighters need to wear full
PPE including SCBA in the sandy by position and shall consist of a minimum of
two personnel. Standby firefighters provide for compliance with 2in/2out
requirements.
RIC will be considered following WAC 296.305.05001 (10)(f)
When personnel on the scene have been assigned to accomplish the initial strategies
and tactics (suppression, search, ventilation, back up line) the incident commander
shall consider the establishment of a RIC.
It is the policy of all agencies adopting this document to follow WAC 296.305:
Early consideration should be
given to providing one or more
rapid intervention teams
commensurate with the needs
of the situation.
• Driver/operators on a 3 person crew need to have their SCBA donned in the stand
by position prior to any rescue attempt. They must remain in positive
communications with the entry team.
• Command officers that arrive before other companies can be used as part of the
stand by crew when appropriate gear is donned.
• If no imminent life hazard, do not enter the structure until the two outside are
ready and have communication with the entry team.
Civilian rescue shall only be made when the officer has significant
reason to believe there is a life hazard.
Entry due to the
assumption that all structures are occupied until proven wrong will
not be allowed.
Other duties outside the structure may be performed
in preparation for entry while other resources arrive.
The incident Commander shall not allow RIC deployment into the following, but not
limited to “NO GO” situations:
•
•
•
•
Extreme hazard to RIC companies with a high likelihood of severe injury or death
Uncontrolled fire growth
Eminent collapse
No potential to save a live firefighter
RIC companies must wait until the
Incident Commander has given a “GO”
command to the RGS.
When a company is assigned to establish RIC, that company will find a location near
the structure but outside of the IDLH to lay out a tool cache and green tarp.
The RIC should:
• Perform a 360 size up
• Consider second means of egress
• Consider softening the building
• Consider gathering all RIC bags on the scene for placement in the RC tool cache
The company officer will assume the role of RIC Group Supervisor (RGS). RGS shall
be issued a second portable radio in the event of a RIC deployment.
RIC may support fire ground operations in the area of the RIC tool cache.
RIC personnel will NOT be assigned other tasks.
• 2 firefighters with PPE, Portable Radio & SCBA
• Green tarp
• RIC pack
• Air bottle
• Mask
• Universal air connection
• Wire cutters
This is a minimum list.
Some departments may want to alter this list.
Remember…The initial RIC should travel light and fast.
A secondary RIC pack may be the bigger tool cache
carried by supplemental RIC’s
• Power saws
• Ground ladders
• Maul or sledge hammers
• Pry or wrecking bars
• Hydraulics power tools
• Struts / Hi-lift jacks
• Cribbing
• Stokes basket and/or backboards
• BLS/ALS kits
• Acknowledge the MAYDAY/EMER activation
• If the firefighter calling a MAYDAY is coherent, consider having him/her
activate the EMER button to move that firefighter to EMER channel.
• Declare emergency radio traffic
• Determine the nature of the emergency and who is involved
• Get Acknowledgment from dispatch agency and emergency tones
• Give GO or NO GO to RGS
• Request an addition alarm to assist with ongoing firefighting operations and/or
RIC activities
• Emergency PAR
• Face-to-face with RGS
• Consider separate tactical channel for RIC activities
• Re-evaluate the incident action plan
• Do NOT deploy until directed by the Incident Commander
• GO or NOT GO
• Determine to the greatest extent possible to following information:
• Nature of emergency
• Who is involved? Company(s) and name(s)
• Last known location and assignment
• The needs of the firefighters
• If possible make contact with firefighters in trouble
• Instruct the firefighters to activate their pass alarms intermittently
• Make contact with other companies who are or were working in the same
area as the company in trouble.
• Formulate a plan
• Request additional companies be assigned to RIC
• At least one RIC shall be ready to deploy at all times.
• As other companies are assigned to RIC ensure the following:
• Correct radio channels for RIC
• RIC understands who is in trouble. Company and name.
• What has been done previously
• Consider a medical team ready to receive firefighters
• Minimum of 1 ALS unit for each troubled firefighter
• Consider obtaining an aide for RGS
• Keep IC updated with RIC activities
• Ensure an additional alarm has been requested by the Incident Commander
• While waiting for the GO or NOT go the RIC members should perform a 360 hot
lap around the structure. 1 firefighters going clockwise the other firefighter
counter-clockwise. Look for structural changes and listen for PASS alarms or
firefighters calling out for help. Report back to RIC area and await deployment
from RGS.
On the hot lap if your hear a PASS or hear firefighters calling for help but cannot see
or reach them, return to RIC area and report your findings.
You may want to start your search area from where you heard the PASS.
Only delay your return to the RIC area if you can positively make a difference in
rescuing a firefighter . Radio your intentions to the RGS.
• Utilize good tool management
• Initial RIC should travel light and fast. Their primary task to located the
firefighter(s) in trouble and get air to the mask if needed. Radio to the RGS
any needs for firefighter removal
• CAN report to the RGS
• Follow sound air management practices
Do you know who you’re looking for?
• When the troubled firefighter is located:
• Silence the PASS alarm (listen for more)
• Check air supply or troubled firefighter(s) and RIC
• Discover the following:
• Is the firefighter conscious or unconscious
• Is the firefighter alive or deceased
• Is the firefighter entangled or entrapped
• Is the firefighter ambulatory or will need assistance
• Perform a 360 sweep of the area for other hazards or troubled firefighters
• Radio your needs to RGS.
E31 to RIC group
E31 from RIC group go ahead
E31 needs pinch point bars and cribbing an two more companies. We found one downed firefighter
unconscious from E81. E31 is less than 50 on air.
E31, RIC group copies…E31 needs pinch point bars and cribbing and two more companies. you found
one downed firefighter unconscious from E31. E31 is less than 50 on air
E31…Affirmative
This presentation shared by Snohomish County Fire District 7