Pump Room Hazard Incident

Download Report

Transcript Pump Room Hazard Incident

Pump Room Hazard Incident
Marine Chemist Association
2012 National Seminar
Chicago, IL
August 13, 2012
Pump Room Hazard Incident
27 April 2001
Commandant Notice 16000
CONFINED SPACE ENTRY POLICY ABOARD
MERCHANT VESSELS
FOR MARINE SAFETY AND
ENVIRONMENTAL PROTECTION PERSONNEL
Pump Room Hazard Incident
Current guidance for confined space entry is in the form of
recommended Safe Work Practices (SWP’s) contained in the
Marine Safety Manual (MSM), Volume I, Chapter 10.
Although much of the guidance in the MSM has been
modified over the years and has been incorporated into
SWP’s in the current version, the general policy of requiring
an NFPA Certificated Marine Chemist to test and certify
confined spaces prior to entry by Coast Guard personnel has
not changed.
Pump Room Hazard Incident
Commandant Notice 16000
Who must certify confined spaces on
merchant vessels safe for entry by
Coast Guard personnel?
Pump Room Hazard Incident
Commandant Notice 16000
A Certified Marine Chemist shall conduct the
initial inspection and certify confined spaces
on merchant vessels “Safe for Workers”
before entry by Coast Guard personnel.
Pump Room Hazard Incident
February 17, 2011
M/T Wilana
Crude Oil Carrier
U S Coast Guard COC Inspection
Loop Anchorage
Pump Room Inspection
Pump Room Hazard Incident
February 17, 2011
M/T Wilana
Crude Oil Carrier
CCR Fixed Gas Monitor Pump Room Readings
O2 – 20.9%
LEL – 0%
H2S – 0ppm
Pump Room Hazard Incident
February 17, 2011
M/T Wilana
Crude Oil Carrier
Rineken Portable Gas Monitor Pump Room
Readings
O2 – 20.9%
LEL – 0%
H2S – 0ppm
CO- 0ppm
Pump Room Hazard Incident
February 17, 2011
M/T Wilana
Crude Oil Carrier
MSA Orion Portable Gas Monitor Pump Room Readings
at the bottom of the pump room
O2 – 20.8%
LEL – 46%
H2S – 0ppm
CO- 0ppm
Toxirae PGM30
THC - >2000ppm
Pump Room Hazard Incident
February 17, 2011
M/T Wilana
Crude Oil Carrier
Vacuum Assist Stripping System (VASS)
Automatic Stripping System (AUSS)
Pump Room Hazard Incident
Pump Room Hazard Incident
Pump Room Hazard Incident
After 1 hour additional ventilation with both
ventilators:
The pump room was retested and entry was
authorized for the chemist and pumpie to enter
and install a blind flange on the goose neck
vent
Pump Room Hazard Incident
With both ventilators running, the atmosphere was cleared for
U S Coast Guard personnel
Readings were as follow:
O2 – 20.9%
LEL – 0%
H2S – 0ppm
CO- 0ppm
Benzene – <0.1ppm
THC - <0.1ppm
Pump Room Hazard Incident
Pump Room Hazard Incident
Pump Room Hazard Incident
Pump Room Hazard Incident
Pump Room Hazard Incident
Pump Room Hazard Incident
The Marine Chemist Qualification Board was notified.
U S Coast Guard Eight District was notified.
American Bureau of Shipping, via Francis Calton, was
notified.