HYDROMETERS MOST RELIABLE COMBINATION MASTER VALVE, WATER METER AND FLOW SENSOR HYDROMETERS Combination - Master valve - Water meter - Flow sensor Available sizes 1½” to 8”: - 1½” and 2” are threaded - 3” to 8” are flanged 3” Hydrometer Accommodate flow ranges from 1.8 gpm to 1500 GPM 1 1/2” Hydrometer 2 HOW THEY WORK 3 APPLICATIONS MASTER VALVE, FLOW SENSOR COMBINATION Ideal for places where space is limited Requires no straight pipe upstream or downstream for accurate measuring-- ± 2% in accuracy Fully compatible with most central control systems Available configurations: - Manual Electric Normally Closed (-MEL) - Manual Electric Normally Open (-MEL-NO) - Pressure Reducing Electric Normally Closed (-PRMEL) - Pressure Reducing Electric Normally Open (-PRMEL-NO) 4 APPLICATIONS FITS NICELY INTO A STANDARD VALVE BOX 5 HYDRAULIC VALVE PERFORMANCE Precision hydraulic valve and water meter in a single unit Perfect as a master valve and flow sensor Saves space and installation costs Rugged heavy duty construction 3” Hydrometer 6 HYDROMETER FEATURES Double chamber valve for positive opening and closing – no springs required 6” Hydrometer is single chamber Adding pilot valves and solenoids enables remote and automatic operation Hermetically sealed register – just one part touches water Optional control functions - Manual Electric - Pressure reducing manual electric - Other configurations upon request 7 HYDROMETER FEATURES Straightening vanes allow compact installation - no upstream or downstream Hermetically sealed register in a dry compartment Upper and lower valve chamber straight pipe requirements Low head loss Ideal for high pressure applications Impeller 8 Straightening vanes HYDROMETER SPECIFICATIONS SPECIFICATIONS Maximum Working Pressure Minimum Working Pressure Maximum Liquid Temperature Body Material Connections Diaphragm 9 235 psi 14 psi 140° F Cast Iron with Epoxy Coating Flanged, Threaded Reinforced Natural Rubber INSTALLATION REQUIREMENTS Must install upright Pipeline should be thoroughly flushed before installation No straight pipe installation requirements Install proper size and type of air vents to eliminate air 3” Hydrometer Straight Pipe Install: Upstream: 0 x D Downstream: 0 x D 10 METER REGISTER WITH PULSE OUTPUT Pulse output is standard Allows for communicating with most central controllers, data loggers, and monitoring equipment 11 PULSE OUTPUT MODELS AVAILABLE Low frequency “dry contact” using a reed switch - 1 or 10 gallons per pulse Photo diode—higher frequency than dry contact by a factor of 10 - 0.1 to 1 gallon pulse High frequency photo diode provides from 10 to 200 pulses per second (depending on the flow rate) Register with Reed Switch Register with Photo Diode Output 12 RECOMMENDED REGISTER OUTPUT Recommended Register Type. CONTROLLER MANUFACTURER MODEL Baseline Basestation Hunter ACC 2-Wire Rain Bird MDC & Maxi Signature All Models Sentinel Toro TDC 2-Wire Toro Rainmaster 13 All Models RECOMMENDED REGISTER TYPE PDH PDH RS RS PDH PDH RS (1” to 4”) PD (6” and 8”) HYDROMETER PERFORMANCE DATA Size 1 1/2" 2" 3" 4" 6" Lowest Flow Lowest Flow Nominal Flow Maximum Flow Within ± 5% Accuracy Within ± 2% Accuracy Within ± 2% Accuracy Within ± 2% Accuracy 1.8 GPM 4.4 GPM 44 GPM 55 GPM 5.3 GPM 20 GPM 66 GPM 95 GPM 14 GPM 53 GPM 176 GPM 220 GPM 21 GPM 79 GPM 264 GPM 380 GPM 53 GPM 198 GPM 660 GPM 860 GPM Cv Size 1 1/2" 2" 3" 4" 6" 8" 14 Flow Rate @ 1.0 psi of Headloss 23 GPM 35 GPM 92 GPM 139 GPM 347 GPM 624 GPM 1½” Globe Hydrometer 3” Globe Hydrometer WHY USE A HYDROMETER SAVES SPACE Combination master valve, water meter and flow sensor all in one unit Does not require any upstream or downstream straight pipe for proper function. ACCURACY ACROSS A WIDE FLOW RANGE Accuracy is ±2% across the entire flow range—offset is = 0 WATER METER CANNOT LOOSE DATA Standard with odometer register 15