Center for Detectors Space Needs

Download Report

Transcript Center for Detectors Space Needs

Center for Detectors Space Needs
•
•
•
•
•
•
•
11 offices for professors, staff, post-docs
10 offices/cubicles for students
>2500 sq. ft. lab space plus three
workshop rooms
conference room for >15 people
>500 sq. ft. clean room
office, lab, clean room co-located
CfD-only access to all areas (ITAR)
Center for Detectors Space Needs
• office space
– 11 offices for professors, staff, post-docs
•
•
•
•
•
•
•
•
•
•
•
Don Figer, Professor
Brian Ashe, Engineer
Brandon Hanold, Engineer
Don Stauffer, Engineer
Tom Montagliano, Engineer
Joong Lee, Engineer
Ben Davies, Assistant Research Scientist
post-doc 1 (NSF/AAG) expansion positions are underlined
post-doc 2 (NASA/PIDDP2010)
professor
administrative assistant
Center for Detectors Space Needs
•
office space
– 10 offices/cubicles for students
•
•
•
•
•
•
•
•
•
•
Christine Trombley, AST PhD
John Frye, CE MS
Max Bobrov, CE MS
Chris Maloney, uE MS
Kim Kolb, CIS MS
Tom Praderio, EE MS
Brian Glod, EE MS
Matt Simpson, Biotech
John Breese, CE MS
graduate student (NSF/AAG, Google2010)
Center for Detectors Space Needs
•
lab space
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
>2500 sq. ft.
will be used to execute the following programs: PIDDP2006, PIDDP2007, APRA2006,
TDEM, Moore (see funding chart), likely new projects (PIDDP2010, NSF/ATI, NSF/AAG)
must be able to accommodate three collocated 8x4 feet optical tables with 3 feet of
surrounding open area
3 separate small lab rooms for cryogenic compressors, dark room, assembly room
4x220V/30A outlets (120A total load), with emergency power (cost allowing)
20x110V/15A outlets (75A total load), with emergency power
compressed air service drops in all lab areas
nitrogen gas service drops in all lab areas
cool water service drops in all lab areas
keycard access for CfD personnel only due to ITAR
existing counters in all areas
existing cabinets in all areas
ability to have black-out shades on windows in one dark room
ability to connect 20 computers to network
venting for solder station
nearby area with sink
Center for Detectors Space Needs
• clean room
– >500 sq. ft.
– class 10,000 with air flow to support class 100 on flow
bench
– accessible chase space (~100 sq. ft.)
– 1x220V/30A outlets
– 10x110V/15A outlets (30A total load)
– compressed air service
– nitrogen gas service
– cool water service
– gowning ante-chamber
– closed access for ITAR restrictions
Center for Detectors Space Needs
•
cost estimates (total = $11,075)
–
–
–
–
–
–
$975, move two optical tables (Al’s moving services)
$500, move flow bench (Al’s moving services)
$1000, 220 Volt installation (via FMS)
$2100, three sets of 40 ft. helium hoses
$2000, keycard
$2000, network jacks/activation (might not be
needed if existing jacks are already activated)
– $2500, backup power ($2500 was the cost for this in
the RIDL)