SOLAR ENERGY
German Solar Market is Largest in Europe
Comparing America Solar Radiation to Germany
Look and THINK of all the Unused Solar Opportunity in AMERICA
SOLAR ENERGY
SOLAR ENERGY
SRCC Collector Performance Ratings
Flat Plate vs. Evacuated Tube
Collector
VELUX
CLI U12 4000
Viessmann
Vitosol 200F
Apricus
Model AP-20
Apricus
Model AP-22
Thermomax
AST20
Thermo Tech
Mazdon TMA-600-20
Viessmann
Vitosol 300T
Collector Type
Flat
Plate
Flat
Plate
Evacuated
Tube
Evacuated
Tube
Evacuated
Tube
Evacuated
Tube
Evacuated
Tube
Gross
Net
Output (1000 Btu/panel/day)
Output (Btu/panel/day per s.f. gross) Output (Btu/panel/day per s.f. aperture)
Rating Category Area (s.f.) Area (s.f.) Clear Day Mildly Cloudy Cloudy Day Clear Day Mildly Cloudy Cloudy Day Clear Day Mildly Cloudy Cloudy Day
C - warm climate
27.06
23.18
29
20
11
1072
739
407
1251
863
475
D - cold climate
27.06
23.18
19
11
4
702
407
148
820
475
173
C - warm climate
27.16
25.12
30
21
12
1105
773
442
1194
836
478
D - cold climate
27.16
25.12
22
13
5
810
479
184
876
518
199
C - warm climate
29.16
25.6
26
19
12
892
652
412
1016
742
469
D - cold climate
29.16
25.6
22
15
9
754
514
309
859
586
352
C - warm climate
32.11
28.2
26
19
12
810
592
374
922
674
426
D - cold climate
32.11
28.2
22
15
9
685
467
280
780
532
319
C - warm climate
30.67
26.87
23
16
9
750
522
293
856
595
335
D - cold climate
30.67
26.87
16
9
3
522
293
98
595
335
112
C - warm climate
32.94
24.26
26
19
12
789
577
364
1072
783
495
D - cold climate
32.94
24.26
22
15
8
668
455
243
907
618
330
C - warm climate
30.98
26.95
26
19
12
839
613
387
965
705
445
D - cold climate
30.98
26.95
23
16
9
742
516
291
853
594
334
NOTES:
1. In general flat plat collectors always out perform evacuated tube in warm climates -- exception on overcast/cloudy days performance is about equal.
2. Warm Climate performance is indicative of when the fluid temperature entering the collector is 36 degrees warmer than ambient air temperature -- Approx. Ambient Temps above 50 degrees.
3. Cold Climate performance is indicative of when the fluid temperature entering the collector is 90 degrees warmer than ambient air temperature -- Approx. Ambient Temps below 50 degrees.
4. On an annual basis, flat plate collector systems provide more energy due to increased performance when the sun is out and it is not cloudy.
SOLAR ENERGY
Advantages of Flat Plate vs E Vac
Flat Plate Collector is more Durable Resistant to Damage
Flat Plate Collector is easier to clean and keep free of debris
Flat Plate Collector is more Aesthetically Pleasing in Appearance
Flat Plate Collector can be Roof Deck Mounted for a Very Low Profile
Which Units Instill Confidence in You and Would you place
On your Home ??