Unico for Inside Salepeople

Download Report

Transcript Unico for Inside Salepeople

What makes up a Unico
System
Understand What to Ask
How to Place an Order
•Sound Attenuator
(UPC-26C)
•Outlet
(UPC-56B)
•Elbow
•Plenum
•Blower Modules
•(2430,3642, 4860)
•Supply Tubing
(UPC-25)
Heating Module
•(MH2430, MH3660)
•Cooling Modules
•(MC2430, MC3642, MC4860)
•Return Air
Adapter (UPC59-xxxx)
•Sound Attenuator
(UPC-26C)
•Secondar
y Drain
Pan
•Return
Air Duct
•(UPC-04-xxxx)
•Return
Air Box
•(UPC-01-xxxx)
The Load
• What is Cooling/Heating Requirement
• Remember, a BTU is a BTU
• Unico has sizes from One to Five Tons of
cooling
• Unico can provide up to 20 KW of electric
heat
• Unico can provide up to 150,000 btu
output of hot water heat
Sizing the Job
• Use the ACCA Manual “J” or ASHRAE
equivalent
• A Load calculation is the same for Unico
as for all other HVAC systems
• Unico provides a Bulletin 40-10 which
contains a very simple sizing guide based
on older building construction
Ask for the size in Tons
Remember a Btu is still a Btu
This is the CONTRACTOR’S
responsibility
Unico Sizes
•
•
•
•
•
M1218
M2430
M3036
M3642
M4860
•
•
•
•
•
1 to 1 ½ Tons
2 to 2 ½ Tons
2 ½ 3 Tons
3 to 3 ½ Tons
4 to 5 Tons
Air Handler Position
• Vertical or Horizontal
• If Vertical:
– Order Vertical Stand
– Don’t order Return Air
• If Horizontal:
– Order Return Air Assembly
– Order Secondary Drain pan
Return Air Assembly
• Return Air Box: UPC1XX*
• Return Air Duct: UPC4CXX*
• Return Air Adapter: UPC59BXX
• XX=Size in Tons
Return Air Box
Return Air Duct
Return Air Adapter
Unico Air Handlers
Air Handlers
• 5 Sizes
– 1 to 1 ½ Tons
– 2 to 2 ½ Tons
– 2 ½ to 3 Tons
– 3 to 3 ½ Tons
– 4 to 5 Tons
• All modular except for M1218
M1218
One –Piece Unit
Vertical Application
Vertical Air Handler
Modular Unit – Vertical Config.
MV2430
One-piece AHUs
The Unico Blower Module
Features and Benefits
Today we use an EC Blower
Motor
ECM … PSC
How does it work?
• Uses the Emerson EC motor, a very
common industry motor
• The control for the motor is specific for the
designs of the Unico system.
• Sets a constant CFM by adjusting the
RPM to conform with the Unico System
fan curve
LED Lights
Default Settings
How to Connect
Unico System Software
Mode
Fan Recirculation (G)
Low Cool (Y1)
Low Heat (W1)
High Heat (W2)
Emergency Heat (E)
Percentage
(of high cool airflow)
50
75
75
100
100
The Cooling Module
• DX or Chilled Water
• Cooling only or Heat Pump
Coil Module
INSTALLING THE TXV
TXV is shipped taped to condensate
pan (Not factory installed)
Expansion
Valve
“Chetleff” Fitting
External
Equalizer Line
Liquid
Line
Distributor
Liquid
Line
Expansion
Valve
Distributor
External
Equalizer Line
Bulb
Seal Plate
Bulb
Seal Plate
IL00390.CVX
IL00392.CVX
Unico Condensate U-Trap
(Included in the Coil Module)
Unico Part No.
Description
A00924-G01
U-Trap, Modular
A00924-G02
U-Trap, M1218
A00924-G03
U-Trap (Float Switch), Modular
A00924-G04
U-Trap (Float Switch), M1218
Heating Options
Electric
Furnace
• Hot Water Heating
Module
• Geothermal (not shown)
Plenum Type
• 26 gauge Single Wall K/D pipe
• Use full flow tees and elbows
• NOT Unico supplied
Supply Tubing Rules
• Make sure you use a MINIMUM of five
outlets per ton
• Outlets are sold:
– Boxes of 2 ½” tubing (five pieces per box)
– Boxes of Installation Kits (five pieces per box)
Small Duct Connectors
UPC-228 Flanged Takeoff, for round metal (UPC-228F for square metal)
frame-in
Outlet Kits
2 1/2” tubing (5 per box)
Installation Kit UPC289F (5
pieces each)
Installation Kit Components
Winter Supply Shut-Off
Metal Take-Off
C lamps, Black & Silver
Installation Kit Components
Toggle Bolts & Screws
White Plastic Outlet
Tools
• Turbometer
• UPC 54
• Measures wind
• Clamp Pliers
speed in Knots
• Knots x 2.37 = CFM
New prod.
Need to Complete Unico
System
• Condensing Unit or Heat Pump
• Tape (UL 181A rated)
• Line set, disconnect, etc.
Unico Installation Overview