Binks Smart Pump
Smart Pump Product Line
Electric Smart Pump
• E2-20: 5 GPM (260 PSI)
• E2-30: 8 GPM (260 PSI)
• E4-60: 16 GPM (260 PSI)
• E4-90: 24 GPM (203 PSI)
Smart Pump Product Line
Accessories:
• Low Shear Smart BPR
 ¾” to 2” Connections
• Smart Card:
 Automatic controls for
“Smart Circ” operation
Description E2-20: 5 GPM
• Fluid Sections
• CV Drive Section
• 40:1 Gearbox
• 1.5 HP AC Motor
Description E2-20: 5 GPM
CV Cam
Slide Rails
Cam Follower
Swivel Joint
Tension Springs
Description E2-20: 5 GPM
Motor Speed
(HZ)
Pump CPM
Fluid Flow
(GPM)
20
9.8
1.23
25
12.25
1.53
30
14.7
1.84
35
17.25
2.16
40
19.8
2.48
45
22.25
2.79
50
24.7
3.09
55
27.1
3.39
60
29.5
3.69
65
31.85
3.99
70
34.2
4.28
75
36.6
4.58
80
39
4.88
• AC Motor drives gear box and CV Cam.
• Motor is controlled by inverter with either manual or PLC instruction.
• The motor frequency is directly proportional to the Fluid Output!
Description E2-30: 8 GPM
Main Pump Assembly
Main Components
• 2 HP Motor & Gearbox
• Main Cam Shaft and Bearings
• 2 Cylinders 4 Ball Check
• Carriage and Cam Follower
• Carriage Support Shaft and
Linear Ball Bearing Bushes
Description E2-30: 8 GPM
• 2 HP motor reduced
through 56:1 gearbox.
• Single “constant velocity”
cam & carriage assembly
ensures no “hard”
connections.
• (2) horizontally opposed
fluid sections provide 8
GPM fluid output.
E2-30 Fluid Section
• Quick disconnect
fluid section.
• Internal piston/fluid
seal.
• Low pressure
bellows seal.
• “Run to Failure”
back up seal.
Description E4-60 & E4-90
16 & 24 GPM
Main Pump Assembly
Main Components
• 5 HP Motor & Gearbox
• Main Cam Shaft and Bearings
• 4 Cylinders 8 Ball Check
• Carriage and Cam Follower
• Carriage Support Shaft and
Linear Ball Bearing Bushes
Description E4-60: 15 GPM
Cam area drives (4) horizontal fluid pistons therefore providing a (4) cylinder true positive
displacement operating pump.
View showing Min Max
Cylinder position
Quick Disconnect Fluid Section
“Module” Designed Fluid Section
QD Sanitary
Clamp piston
shaft connection
Bolted
connections
Complete fluid section can be removed by disconnecting (4) sanitary clamps
and removal of (8) bolts!
Bellows: “Run to Failure”
Use of secondary chevron
style seal behind bellows
provides a back up seal
and allows for visual
indication of bellows
failure.
• Material flow path
•Secondary Seal (vertical
piston pump style seal)
• Bellows location
Provides visual indication
of bellows failure and
allows operator time to
repair before affecting
production.
E4-60 Energy Consumption