Transcript Slide 1

Power Series v4.6, RFK5564 and PK/RFK5500 v1.3

BENEFITS

• Expanded wireless zone support • Simplified programming • Quick Installation

FEATURES

• 64 wireless zone support on PC1864 • Pre loaded English, French, Spanish and Portuguese Zone Label Libraries • Easy wireless device enrollment process 1 1

Application Notes

• 33-64 wireless zone support on the PC1864 is only available using the RFK5564 • RFK5564 will function normally on PC1616 and PC1832, but will only support 32 wireless zones • RFK5564 includes 64 wireless zones, Label Libraries and easy wireless programming • RFK5500 includes Label Libraries and easy wireless programming • PK5500 includes Label Library • New DLS IV drivers are required. Only supported by DLS IV. For RFK5564, you must select PK5500 v1.3 and RFK5164 v5.4. For the RFK5500, please select the RF5132 v5.4

• Zone Labels are fully customizable. Existing Zone Label programming maintained.

Application Notes

• Yellow version stickers applied to master and product cartons.

• If using a V1.2 or lower keypad on a V4.6, wireless programming will be 2 digit entries. Enter sections [01]-[99], allows for 64 wireless zones. For sections [100]+ you must use a RFK5564 keypad.

• Template programming – Enter “0” to first digit to secure the first 8 zones programming. Same functionality as SCW.

• Features Removed: Robophone, Private line and Scantronics communication formats, Maintenance code, PGM 32 - Open after Alarm and PGM 33- Bell status & Programming access output.

• RFK Improvements – Receiver and Repeater placement test

• • •

Easy Wireless Device Enrollment

Initiation of the easy wireless device enrolement process is performed by accessing installer’s programming [*][8][Installer Code], followed by entry of section [898]. The keypad will prompt “Wireless Enrolment Mode” Wireless Enrolment Mode Activate the device to enrol as described in the associated installation sheet. The electronic serial number (ESN) is displayed. Press [*] to confirm the ESN, or [#] to discard. This screen will remain until the installer either confirms or discards the serial number.

After confirmation of the wireless key or zone serial number, the system will automatically prompt for the zone number. If 3 zones have already been enrolled, the zone number will be preloaded with “04”, however the installer may decide to enrol the zone as zone number 15. The next zone that is enrolled will preload the zone number with “04” again and not “16”. Also if the 1 st through 14 th serial number is enrolled (in this situation), the next available zone number will be “16”, and not “15”, as the previous zone number slots are already occupied.

The installer can enter digits [01] to [64] if the serial number is for a sensor, and digits [01]-[16] if the serial number is from a wireless key. Press (*) to accept the zone number automatically selected by the system, or simply enter the 2 digit zone number to proceed to the next step.

25BECE Confirm ESN? * Press (*) or Zone #: 01

Easy Wireless Device Enrollment

• • Once the zone number has been selected, the installer shall select the zone type for the zone. The default zone type suggested by the system is linked to the serial number that has been received. The installer may press [*] to select the default zone type, press [#] to exit to return to the serial number confirmation screen, or can enter any 2 digit zone type. The system will automatically enable zone attribute 8, wireless, after the zone type has been selected. The system will also automatically assign the key or zone to partition 1. Panic pendants have the wireless supervision bit automatically disabled, as they are not supervised devices.

Device Type 2 (Door/Window Contact) 3 (PIR or Glassbreak) 4 (Smoke Detector) 5 (Pendant) 8 (CO Detector) Press (*) or [01] Delay 1 Zone Definition [05] Interior, Stay-Away [88] Standard 24Hr Fire (Wireless) [16] 24 Hour Panic [81] 24 Hour CO Detection Zone Type: 01 After the zone type has been selected, the keypad will sound acknowledgement beeps and automatically enter individual device placement test for the zone that was enrolled. After the device has been placement tested, the installer can press # and the system will return to waiting for new serial numbers (step 1) Activate Device for Test, Exit #

Label Library Operation

Example for programming Upstairs Motion

• • • • • • Starting Screen ([*][8][Installer Code][*][001]) – Note the cursor position Installer presses [*] Select Option <> Words Zone 1 The installer presses [*] again Aborted (001) The first word entry is Up, which is word 188 in the list. So the installer enters 188 The installer presses [*] to select the word, and is now brought back to the label screen to show the word entry. Note the cursor position.

The installer presses [*] again Select Option <> Words Up (188) Upne 1

• • • • • •

Label Library Operation

Continued Example for programming Upstairs Motion

The installer presses [*] again Aborted (001) The next word is Stairs, which is number [174] Stairs (174) The installer presses [*] and is brought back to the label screen UpStairs_ Recognize whether the next word will fit on the display. Each line supports a maximum of 14 characters. The phrase UpStairs Motion requires 15 characters so it won’t fit in the top line. The keypad will automatically move the word that doesn’t fit to the next line. press [*][*] to re-enter the word library, and enters number 124 for Motion.

Motion (124) UpStairs Motion_ The installer presses [*] again to select the word and is brought back to the label screen. If there isn’t enough space on the BOTTOM line to enter a word, program as many characters as possible in the space remaining.

As a final step, the installer must still save the label. Pressing # at this screen will exit the label programming entry and the label will return to the previously programmed label. To save the label, the installer must press [*] to access label programming options and then scroll left once. Press [*] again to save the label

Top Ten Zone Labels

• Front Door [080][052] • Back Door [017][052] • Garage Door [083][052 • Living Room Motion [111][183][124] • DownStairs Motion [080][174][124] • Hallway Motion [088][124] • Kitchen Window [103][190] • Bedroom Window [022][190] • Smoke Detector [169][049] • Master Bedroom [117][022]