Hygienic process connections

Download Report

Transcript Hygienic process connections

Hygienic process connections
 Dairy connection acc. to DIN 11851
 Aseptic connection acc. to DIN 11864
 Aseptic connection NEUMO
 BioConnect- NEUMO
 SMS-Connection
 Clamp connection acc. To ISO2852
 Tri Clamp®-connection
 Varivent®- connections
 APV-c connections
 DRD- welding adapter for vessels
Process connection DN 25 Ingold
 Installation recommendation
1
Dairy process connection DIN 11851
Different parts of the dairy connection DIN 11851
from left to right: nut, threat part, conical part, seal
Annotation:
The dairy connection acc. to DIN 11851 is, in Europe, the most used screws in food and beverage Industry. It
can be used as well to connect to a vessel either than to a pipe. Beside the outstanding price, the robust
equipment is the biggest advantage. The hygienic conditions in this connection are, due to the big, undefined
sealing, not the best.
The sensor can’t be mounted complete flush to the process.
2
Dairy process connection DIN 11851
3
Aseptic connection acc. to DIN 11864
Annotation:
The announced successor of the 11851 is the 11864
connection. Here we find a defined load and a very
small surface of the sealing to the process.
The DIN 11864 follows the engineering rules of
EHEDG (European Hygienic Equipment Design
Group).
Unfortunately, no unique standard has developed so
far. 2 different versions are described:
Form A is a construction using an O-Ring seal.
Form B is using a special formed sealing.
Example: aseptic connection acc. to DIN 11864 A
(Photo: Stericom / GEA)
4
Aseptic connection acc. to DIN 11864
Example, aseptic connection acc. to DIN 11864
(Photo: Stericom von GEA - Version A)
Advantage of this sealing concept is the standard O-ring. It is easy and cheap to purchase.
Disadvantage of the O-ring is his susceptibility against vacuum.
5
Aseptic connection acc. to DIN 11864
Series 2 - sealing version A, flange
Series 1 - sealing version A, screwed
We also have to differentiate between flange and screwed connection.
For both versions, two series each exist.
Series 1 is the screwed,
series 2 is defined as the flange version.
The sealing is equal for both.
6
Aseptic connection acc. to DIN 11864
Series 1 - sealing version B
The version B is also built in 2 series, one with screwed connection (version 1) and one with flange (version
2). The sealing is guided in a defined room. There is no problem with vacuum, but the purchase and asset
management boroughs more expenses and efforts.
Because of the big installed base of the DIN 11851 and the fact, that there are several connections built to full
fill DIN 11864, this new standard could not prevail so far.
7
Aseptic connection - Neumo
Annotation:
This connection is one Neumo approach for hygienic
connections. It follows the aim of the DIN 11864.
The defined load of the small sealing in a defined and
completely filled room prevents the sealing from being
stressed during installation, and from “breathing” while
temperature changes.
Disadvantage are the small and sensitive edges that easily
can be damaged while handling.
The sealing is realised by a standard
O-ring.
8
BioConnect - NEUMO
Annotation:
The BioConnect was especially prepared for hygienic use in the Pharmaceutical Industry.
It follows the same argumentation then the Neumo Aseptic Connection.
9
Process connection SMS
Annotation:
The SMS process connection is mostly used in
Scandinavia and France. Sensors can be connected neither
to pipes or vessels.
Advantage is the robust construction and the low price of
this equipment.
Disadvantage is the big sealing with all the resulting
hygienic problems
SMS-connection
10
Process connection SMS
Threat, nut, sealing
11
ISO 2852 - Clamp-connection
Annotation:
The clamp connection is as well used in food as in the
pharmaceutical industry.
It is the standard connection in USA/ NAFTA countries (Tri
Clamp). The clamp is used for connections to pipes and to
vessels ISO Clamps are standardised connections for ISO
pipes.
In the ISO world, there are also clamps following DIN
32676. They are used for pipes following DIN 11850.
ISO-CLAMP-Process connection
The clamp connection is sealed by a flat form sealing. The
load to this seal is created at all points by the clamp even.
The seal is stressed less than in a DIN11851connection, but
it is more complicated to install.
Parts of the clamp-connection:
2 x clamp-welding parts, clamp, sealing
12
TRI-CLAMP®-connections
Annotation:
Beside the clamp connections for the DIN/ISO-world, mostly
for USA/NAFTA, the company TRI Clover is preparing the
TRI-CLAMP® - connection. The extend is just close to the
ISO clamps.
Beside the soft plastic sealing, for TRI-CLAMP®-connections
there is also sealing available made from peek. This sealing
ease the installation of the connection, because it sticks on the
clamp part.
TRI-CLAMP®-Prozessanschluss
13
Varivent®-Inline-housing
Annotation:
The Varivent®-Inline housing is used to install instruments in
pipes.
We achieve a good flush mounted installation. The instrument
is mounted direct in the flow. Because of the con-struction,
there is no pressure loss in the housing. The design ease CIP
cleaning.
The connection is sealed by a standard
O-ring. The fastening is realised with a clamp.
This might result in a bad surprise, if the clamp is opened
while there is some pressure left on the process.
14
Varivent®-Inline-housing
Special topic for the Gea Inline-housing is, that 3 types
cover all pipe diameters from DN 10 to DN 162.
They are defined like follows:
Varivent Typ 1 fits for diameters DN 10 and DN 15
Varivent Typ 2 fits just for diameter DN 25
Varivent Typ 3 fits for diameters from
DN 40 up to DN 162
This results in optimised asset management, as well for
the instruments as for the spare parts.
15
Varivent®-Tank-Adapter
Annotation:
Beside the inline housing, there is also a Varivent®- Vessel welding adapter.
Advantage is, that instruments can be used for both.
The version U allows the installation also in tight circumstances like in cone
areas. Because of it’s slight construction it is harder to weld the adapter to
the vessel without damaging it.
The T version needs much more space for installation.
Tank-Adapter Version - U -
16
Tank-Adapter Version - T -
Varivent®-Family
Example: the complete family of Varivent®-process connections
17
APV-Inline-housing
Annotation:
The APV inline housing is according to the connection to the process, quite similar to the Varivent®housing. It delivers the same advantages. The flange is fixed with 4 screws. The sealing is realised with a form
sealing.
A good flush mounted process connection is reached.
Two instruments can be placed in both inline housings.
APV-Inline- housing
18
APV-connection
Annotation:
Also APV offers the possibility to use the same instrument in an inline housing or a tank welded adapter.
Because of its big diameter it mainly is used in cylindrical part of vessels.
Here also, the asset management is supported by interchangeability of the sealing and flange.
APV-welding adapter
19
DRD-welding adapter for vessels
Annotation:
The DRD adapter is prepared to connect instruments to vessel. A
good flush mounted integration is reached. The sealing is realised by a
common flat sealing. The instrument is fixed by 4 screws. This
decreases the risk while opening the flange, even if there is still
pressure on the process.
The DRD flange is well used in food industry.
His disadvantage is the big diameter of 125mm, witch might prevent
the use in the conical part of a tank.
Deltapilot S with DRD-flange
DRD-welding adapter
20
Process connection Ingold DN 25
Annotation:
The Ingold connection DN 25 is mostly used in the pharmaceutical industry. It is the standard connection in
fermenting vessels.
Welding adapter DN 25 with nut and level switch Liquiphant M
21
Process connection Ingold DN 25
Pressure sensor Cerabar M PMP 45
Level switch Liquiphant M
22