The Identifier — Key Features
•
•
•
•
•
•
•
GR-135
“3 Instruments-In-One”:
Search, dose rate and nuclide identification
Fully automatic: 2-step operation
Highest operation usability, one hand, one button,
“joystick” operation
Unsurpassed nuclide identification
Up to 4 detectors integrated into one instrument
Integrated Neutron detection capability
Developed based on the World’s leading
gamma - ray spectrometer, the GR-130 miniSPEC
Key Features
THE IDENTIFIER
Automatic Mode — 2 Step Operation
Docking
Station >
System
Ready
The
IDENTIFIER
EaseApplications
Of Use
Ease
Of Use - Key
Grab &
Go >
Search
and dose rate
GR-135
“Click” >
Nuclide
Identification
THE IDENTIFIER
Highest Operator Usability
GR-135
Ergonomics
•
•
•
•
One hand, one button, “joystick” operation
Operate with gloves
Rugged and lightweight
Well balanced “in-the-hands” feel
The
IDENTIFIER
EaseApplications
Of Use
Ease
Of Use - Key
THE IDENTIFIER
Highest Operator Usability
GR-135
Easy To Use
• Docking station: System ready, battery charged, gain stabilized
• Fully automatic: 2 step operation
1. Grab & go
- Search & Dose Rate
2. “Click”
- Nuclide Identification
• Large readable displays
• Automated operator advisor
- Warning Messages
- Operator Instructions
• “Eyes-Free” audio search and warning system
• Selectable back-lit-display
• Automated correction for display contrast
• 8 to 12 hour battery life, with rechargeable batteries
• Multi language support
The
IDENTIFIER
EaseApplications
Of Use
Ease
Of Use - Key
THE IDENTIFIER
Highest Operator Usability
GR-135
Multiple On-Board Detectors
• Up to 4 detectors can be integrated into one hand-held
–
Sodium Iodide - standard on all instruments
–
Geiger-Mueller - standard on all instruments
– Solid State Neutron - optional
– Cadium Zinc Telluride (CZT) - optional
• Automatic detector data integration for optimal nuclide
•
identification
Full text nuclide classification
–
Industrial / medical / special nuclear materials
–
Nuclide identification
The
IDENTIFIER
EaseApplications
Of Use
Ease
Of Use - Key
THE IDENTIFIER
Automatic Operator Friendly “Advisor”
GR-135
“Eyes-Free” Audio Warning System
•
•
•
Built-in audio output
Audio tone increases as The Identifier is
moved close to the source and radiation
becomes more intense
Operator is able to quickly locate the
exact location of the source
Audio tone increases
as radiation becomes
more intense
The
IDENTIFIER
EaseApplications
Of Use
Ease
Of Use - Key
THE IDENTIFIER
Automatic Operator Friendly “Advisor”
GR-135
Automatically advises operator...
Warning
Warning
Audio tone increases
as radiation becomes
more intense
Warning
Instruction
The
IDENTIFIER
EaseApplications
Of Use
Ease
Of Use - Key
THE IDENTIFIER
Automatic Mode: Search and Dose Rate
Highly sensitive
search / survey
capability:
GR-135
Accurate,
calibrated dose
measurement:
- Uses a very sensitive
sodium iodide detector
(4 cu. in. / 65 cu. cm)
- Dose calibrated
based on Cesium137 at factory
- Measures total counts
per second
- Dose accurate to +/5% over 0 - 3 MeV range
- Chart recorder to
emphasize small
radiation level changes
- Energy corrected
dose rate
- “Eyes-Free” audio search
to locate source
- “Neutron alert” if neutrons
detected (Neutron
optional)
The
IDENTIFIER
EaseApplications
Of Use
Ease
Of Use - Key
- BAR GRAPH gives user
an easy visual display of
dose hazard
- High dose rate alarm
THE IDENTIFIER
Automatic Mode: Unsurpassed Nuclide Identification
•
•
•
•
•
•
•
•
GR-135
Exploranium has developed a technologically
advanced nuclide identification system “multi-level nuclide I.D.” that uses advanced
deconvolution peak techniques and interference
correction techniques
Optimized for all common nuclides and Special
Nuclear Materials (SNM)
i.e. Uranium-235, Plutonium
Optimized for shielded sources
1024 channel operation
Automatic detector selection:
Sodium Iodide vs Cadmium Zinc Telluride
Automatic gain correction
Clearly displays Type and Isotope
Automatically alarms and displays Neutrons
The
IDENTIFIER
EaseApplications
Of Use
Ease
Of Use - Key
THE IDENTIFIER
Nuclide Libraries
•
•
•
GR-135
Nuclide libraries target most common nuclides for
Special Nuclear Materials, Industrial and Medical
applications
5 different pre-defined nuclide libraries are available.
The desired library is activated through the manual menu
selection:
– STANDARD: Customs / Security / Police / Military...
– Medical
– Industrial
– Waste Management
Special Customizable
For maximum system performance, Exploranium will
customize special libraries for the user (by e-mail)
which can be downloaded using the indentiVIEW software
provided via PC and docking station
The
IDENTIFIER
- Key
EaseApplications
Of Use
Nuclide
Library
THE IDENTIFIER
GR-135 Libraries
•
GR-135
Built-In Library for First Responders (Customs,
Police, Fire, etc.), Medical, Industrial and Waste
BUILT-IN LIBRARIES
Standard (Customs)
Am-241
Ba-133
Co-57
Co-60
Cs-137
F-18
Ga-67
I-123
I-125
I-131
In-111
Ir-192
I
M
S
N
=
=
=
=
Americium-241
Barium-133
Cobalt-57
Cobalt-60
Cesium-137
Flourine-18
Gallium-67
Iodine-123
Iodine-125
Iodine-131
Indium-111
Iridium-192
I
I
I
I
I
M
M
M
M
M
M
I
Industrial
Medical
Special Nuclear Materials
Norm
The
IDENTIFIER
- Key
EaseApplications
Of Use
Nuclide
Library
K-40
Np-237
Pu-239
Ra-226
Tc-99m
Th-232
Tl-201
U-233
U-235
U238/5
Xe-133
Medical
Potassium-40
Neptunium-237
Plutonium-239
Radium-226
Technet-99m
Thorium-232
Thallium-201
Uranium-233
Uranium-235
Uranium-235/8
Xenon-133
N
S
S
N
M
N
M
S
S
N
M
Co-57
Cr-51
Cs-137
Ga-67
I-123
I-131
In-111
Ir-192
Pd-103
Sn-113
Sr-85
Tc-99m
Th-232
Tl-201
Cobalt-57
Chromium-51
Cesium-137
Gallium-67
Iodine-123
Iodine-131
Indium-111
Iridium-192
Palladium-103
Tin-113
Strontium-85
Technet-99m
Thorium-232
Thallium-201
M
M
I
M
M
M
M
I
M
M
M
M
N
M
THE IDENTIFIER
GR-135 Libraries
•
GR-135
Built-In Library for First Responders (Customs,
Police, Fire, etc.), Medical, Industrial and Waste
BUILT-IN LIBRARIES
Waste
Industrial
Am-241
Cs-137
Co-57
Co-60
Ir-192
K-40
Ra-226
I
M
S
N
=
=
=
=
Americium-241
Cesium-137
Cobalt-57
Cobalt-60
Iridium-192
Potassium-40
Radium-226
I
I
I
I
I
N
N
Am-241 Americium-241
Co-57 Cobalt-57
Co-60 Cobalt-60
Cs-137 Cesium-137
Ga-67 Gallium-67
I-123 Iodine-123
I-131 Iodine-131
In-111 Indium-111
Ir-192 Iridium-192
I
M
I
I
M
M
M
M
I
K-40
Pd-103
Ra-226
Sn-113
Sr-85
Tc-99m
Th-232
Tl-201
U238/5
Potassium-40
Pallaium-103
Radium-226
Tin-113
Srontium-85
Technet-99m
Thorium-232
Thallium-201
Uranium-235/8
N
M
N
M
M
M
N
M
N
Industrial
Medical
Special Nuclear Materials
Norm
The
IDENTIFIER
- Key
EaseApplications
Of Use
Nuclide
Library
THE IDENTIFIER
identiVIEW Software
GR-135
“Dock to PC” > identiVIEW Software
•
•
•
The Identifier has a large data storage capability
IdentiVIEW software automatically downloads
stored data and spectrum to your PC
Stored data can then be transmitted to an expert
for review
The
IDENTIFIER
- Key
EaseApplications
Of Use
identiVIEW
Software
THE IDENTIFIER
Manual Mode Features — Advanced User
GR-135
Manual Mode
The manual mode allows the qualified user the opportunity to change
parameters, alarm levels, etc., for both the Automatic and Manual modes,
as well as perform advanced spectrum analysis and other advanced
functions.
Set-Up Mode
The menu-driven “Manual mode” allows the advanced user to
easily define or modify system settings:
• Survey settings
• Dose corrections
• Manual detector selection / override
• Count termination settings
• Alarm message / audio control settings
• Display settings
• Scan stored spectra / replay / download
• Battery condition
• Dose calibration / data averaging
• Multiple language
The
IDENTIFIER
EaseApplications
Of Use
Ease
Of Use - Key
THE IDENTIFIER
Manual Mode Features — Advanced User
GR-135
Advanced Spectrum Analysis
Using a full complement of on-board analysis
tools and system pop-up menus, the IDENTIFIER
provides the advanced user with everything
needed to manipulate and analyze the spectrum.
•
•
•
•
Adjust scaling, zoom and expand peaks
of interest
Customize system settings
Define multiple regions of interest (ROI)
Re-play, allows the re-analysis of selected
stored spectra
The
IDENTIFIER
EaseApplications
Of Use
Ease
Of Use - Key
THE IDENTIFIER
Training
•
•
Exploranium is in the process of developing a number of training
programs ranging from 2 hours to a full day.
These seminars include such topics as:

•
•
GR-135
Basic Radiation
Knowledge


GR-135 Operation


Search Techniques

Field-Based
Role Exercises
Emergency Response
Standard Operating
Procedures (SOP)
Seminar leaders include; in North America — Don Rickard
previously with Canadian Nuclear Safety Commission and in
Europe — Dr. Klaus Duftschmid, previously with the IAEA and
currently involved in customs training
Exploranium is also working on an interactive training CD and
can provide training for trainers
The
IDENTIFIER
- Key Applications
Key
Applications
THE IDENTIFIER
“The IDENTIFIER” - Complete Package
GR-135
The Complete Package Includes:
•
•
•
•
•
•
•
•
•
•
•
•
GR-135 “The Identifier” handheld unit
Operator’s manual
Rubber boot
Docking station + AC power cord
2 - NiCd - batteries
Connection cable (docking station to PC)
IdentiVIEW software
Soft sided carrying case
Pelican shock proof travel/shipping case
Calibration certificate
ISO 9002
CE
The
The
IDENTIFIER
IDENTIFIER
- identiVIEW
- Key
Ease
Applications
Of Use
Software
The
Complete
Package
THE IDENTIFIER
Only Exploranium Provides...
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
GR-135
Automatic Mode - 2 step operation
– “Grab and Go” = Search and Dose Rate
– “Click” = Nuclide Identification
One hand, one button “joy stick” operation
Unsurpassed nuclide identification - optimized for shielded sources
and special nuclear materials
Docking station - recharging, stabilization and
downloading
Large, readable displays 65 x 65 mm (2.5” x 2.5”)
Eyes-free “loud” audio, warning messages
4 integrated multiple detectors - NAI, GM, Neutron, CZT
Free software upgrades
Automatic detector selection - NAI versus CZT
Five nuclide libraries including a customizable
nuclide library
Rugged, durable design - drop tested at 0.75m, with detectors
Large NAI crystal 38 mm x 55 mm (1.5” dia x 2.2”) for extra sensitivity
Excellent battery life, 8 hrs to 12 hrs
Broad energy range 20 KeV to 3.0 MeV and selectable ROI’s
Multi language support
The
The
IDENTIFIER
IDENTIFIER
- identiVIEW
- Key
EaseApplications
Of Use
Software
Only
Exploranium
Provides…
THE IDENTIFIER
Independent Test Evaluations - In Progress!
•
GR-135
The IDENTIFIER is a significant technical advance
over the original Exploranium’s GR-130 miniSPEC
which was successfully evaluated by a number of
organizations:
– ITRAP - IAEA Seibersdorf, Austria
– NRPB, U.K.
– AECL, Canada
– F.B.I. / D.O.E., USA
•
GR-135 IDENTIFIER - Tests In Progress...
– Department of Energy (D.O.E.) - United States
– I.T.R.A.P. - Austria
– N.R.P.B. - United Kingdom
– Customs - Europe
The
The
IDENTIFIER
IDENTIFIER
- identiVIEW
-Test
EaseApplications
Key
Of Use
Software
Independent
Evaluations
THE IDENTIFIER
User References:
•
GR-135
The GR-130 / 135 has sold over 1,500 units in 45
countries, with such notable customers as:
–
–
–
Customs: U.S. Customs (USA), CCRA (Canada),
–
National Research Facilities: DOE (USA), AECL (Canada),
NRPB (UK), I.A.E.A. (Austria), ANSTO (Australia), Health
Canada R.P.B.
–
–
Medical: Medical facilities worldwide, Hospitals...
–
Steel/Scrap Metal: Nucor, Ameristeel (USA),
Avesta, ELG (UK), Nippon Steel (Japan), most steel
mini-mills worldwide...
Police: FBI (USA), RCMP (Canada), Police (Worldwide)
Military: D.O.D., U.S. Army, LLNL, Navy EOD, Navseacom,
AWE (UK), DND (Canada)
Nuclear Power Plants: OPG, Bruce, NBP (Canada),
USA, Europe
The
The
IDENTIFIER
IDENTIFIER
- identiVIEW
-Test
EaseApplications
Key
Of Use
Software
Independent
Evaluations
THE IDENTIFIER
In Conclusion - The IDENTIFIER
•
•
•
•
•
•
•
•
•
•
GR-135
Evolved from the most popular gamma-ray
spectrometer, the GR-130 miniSPEC
3 instruments in one: search, dose rate and
nuclide identification
Fully automatic: 2 step operation
Lightweight, rugged and versatile
Highest operator usability: Easy to use
Unsurpassed nuclide identification
Docking station for immediate readiness
Multiple integrated detectors: GM, Sodium Iodide,
Neutron, CZT
Selectable nuclide libraries
Manual mode for advanced users
The
The
IDENTIFIER
IDENTIFIER
- identiVIEW
- Key
Ease
Applications
Of Use
Software
The
Complete
Package
THE IDENTIFIER
For More Information
GR-135
USA Offices
Head Office
Contact: Mel Sauve
E-mail: [email protected]
6108 Edwards Blvd.,
Mississauga, Ontario CANADA L5T 2V7
Tel.: (+1) 905 670-7071 ext. 305
Fax: (+1) 905 670-7072
European Office
Europe, Middle East, Africa
Contact: D.J. Schooneveld
E-mail: [email protected]
Lagendijk 39, NL-1541 KB Koog aan de Zaan,
The Netherlands
Tel.: (+31) 75 670 4901
Fax: (+31) 75 670 4855
Nuclear - Asia, South America, Australia,
South Africa
Contact: Roy Natherson
E-mail: [email protected]
6108 Edwards Blvd.
Mississauga, Ontario CANADA L5T 2V7
Tel.: (+1) 905 670-7071 ext. 304
Fax: (+1) 905 670-7072
The
The
IDENTIFIER
IDENTIFIER
- identiVIEW
- Key
Ease
Applications
Of Use
Software
Where
To Find
Us...
Nuclear / Security
Contact: Stan DeFilippis
E-mail:
[email protected]
207 E. Ohio St., Suite 262
Chicago, IL 60611 USA
Tel.: (630) 922-6483
Fax: (630) 922-6482
Steel / Scrap Metal - North America,
South America & Asia
Contact: John Bublitz
E-mail: [email protected]
237 South Peters Rd.
Knoxville, Tennessee USA 37923
Tel.: (865) 539-6099
Fax: (865) 539-1916
Nuclear Surveillance / Geophysical - International
Contact: Ed McGovern
E-mail: [email protected]
6108 Edwards Blvd.
Mississauga, Ontario
CANADA L5T 2V7
Tel.: (+1) 905 670-7071 ext. 303
Fax: (+1) 905 670-7072