F4 Overview Presentation
Download
Report
Transcript F4 Overview Presentation
Series F4P 1/4 DIN Process
and Temperature Controllers
1
2
Watlow’s Next
Generation Styling
Series V4T 1/4 DIN
Temperature Controller
Series F4P Temperature
and Process Controller
Series 97 Matching
1/16 DIN Limit
Controller
3
F4P Focus Markets
4
Furnace
and Oven
Applications
Heat Treating
Kilns
Autoclaves
Foundry & Metal
Processing
5
Electronic
Components
and Assembly
Semiconductor
processing
equipment
Electronic assembly
equipment
Test Equipment
6
Packaging and
Sealing
Box Sealing
Shrink Wrapping
Blister Packing
7
Other Focus
Industries
Applications
Analytical
Instruments
Pulp and paper
processing
Petrochemical
processing
8
Ease of Use
The most important
selection factor
following quality and
reliability when
selecting a temperature
controller is
ease of use.
Source:1997 VDC Worldwide
Market Report for Industrial
Electronic Temperature Controllers
9
Enhanced Display and Keypad
Control programming made
easy through advanced
technology
Icons
for international applications
Read-at-a-glance process display
Full message prompting
of operation and setup
10
F4 Operator Interface
Primary
process display
Large 5-digit, 7-segment
display
0.562”
(14.3mm) display digit height
F or C, degree, and decimal point indication
Operations display
4
line X 20 characters per line
High definition back lit LCD
Wide
viewing angle
11
F4 Operator Interface
6
Operator interface keys
Rubber key
Four
switch with tactile feel
navigational keys
Parameter and value selection
“i”
information key
Toggle for help
Dedicated Auto/Manual
operation key
12
F4 Operator Interface
Discrete
LED Indicators
Control
output indication
Alarm active indication
Communications activity
Auto/Manual operation indication
13
Advanced Hardware
Features
20 MHz operation, 16-bit
processor
NEMA 4X, IP 65 sealed front
panel
Shallow 4” (101mm) overall
case depth
FLASH memory for field
software update
14
F4 Industrial Design Features
High strength injection molded case
3.85
“ (97.8mm) behind panel depth
Ergonomic design styling
Compatible
NEMA 4X,
with Series 96 & 97 limit
IP 65 front panel seal
Convenient
4 screw installation brackets
15
F4 Industrial Design Features
Touch safe
wiring termination
Removable
for wiring convenience
Accepts 12 to 22 gauge wires
Positive latching feature
Connection integrity
Withstands equipment vibration
16
Loaded With Standard
Hardware Features
3 universal analog inputs
(2 & 3 optional)
TC, RTD, process (no DIP
switches)
4 digital inputs (standard)
Control functions
Contact closure or DC voltage
17
Modular Hardware Inputs and Outputs
Field replaceable input and output
modules
Dual control outputs
Reverse/Direct or Off
Linear
or time proportioned
Switched dc/open collector,
SSR, process
Alarms (2 standard)
Process, deviation, rate
2
A mechanical relays
18
Leading the Way in Communications
Serial communications
standard
EIA
232 & EIA 485
hardware interfaces
MODBUS
protocol
9600 and 19,200 baud
Allows in field
software updates
19
Hardware Features
Retransmit outputs
2 optional
Current or voltage
Process, set points,
% power
Universal power supply
85 to 265 vac/vdc, 50 to 60 hz
Optional 24 to 28 vac/vdc
20
Performance Specifications
Operating range
Calibration accuracy
0 to +65C
0.1% of span, +/- LSD
(whole digit)
Sensor update rate
20 Hz, 50 ms, Input 1
10 Hz, 100 ms, Input 2
and Input 3
21
F4 Hardware Architecture
Input to Output Isolation
Minimum
500 Vac/Vdc
between blocks
22
Agency Approvals
UL, c-UL 916 listed
User replaceable input and output modules
European CE conformity
EN 50082-2, immunity standard
EN 50081-2, emission standard
EN 61010-1 low-voltage
directive, safety
NEMA 4X, IP 65 front panel seal
23
Software Architecture
Main Page
Operations Page
Setup Page
Factory Page
24
Software Architecture
“Guided” setup & programming
Guided
configuration
Presents
a sequence of parameter
choices needed to complete a
functional configuration
Full
unabbreviated text
Uses
full text messages, not cryptic
parameter and configuration names
25
Software
Operation
Context
sensitive help
Toggle the
“Information”
key
26
Process Value
Bargraph
Displays
View
both
Output 1A and 1B
in graphical format
27
Programming
A User-Named
Alarm
Select
first
line to change
28
Programming
A User-Named
Alarm
29
Programming
A User-Named
Alarm
30
Programming A
User-Named
Alarm
Select
alarm on
Output 1
31
Programming A
User-Named
Alarm
32
Programming A
User-Named
Alarm
33
Programming A
User-Named
Alarm
Enter
“VENT
OPEN” to name
output
34
Programming
A User-Named
Alarm
Save
change,
output naming
complete
35
Programming
A User-Named
Alarm
Return
to normal
operations display
with “Vent Open”
status displayed
36
F4 Software Architecture
Function naming
Optional, up
to 10 characters
Better operator recognition
Enter Alarm Name:
Alarm 1
Adjusts Character
Selects Character
37
F4 Software Architecture
Pop up verification displays
Lets
the user know when the F4 software is
storing changes in Non Volatile Memory
Save Setup Changes
or restore Values?
Restore
Save
38
F4 Software Architecture
Main Page
Display key
Main Page____
Go to Operations
Go to Setup
Go to Factory
control parameters
Up
to 16 customer programmable control parameters
•Set points, alarms, errors, % power
•Inner loop set point (cascade control)
•Bar graphs/set point and process
Gateway to
controller configuration
39
F4 Software Architecture
Main Page____
>Go to Operations
Go to Setup
Go to Factory
Operations Page
Auto tune PID control parameter values
Edit PID
crossover points
Digital set
Alarm
points
set points
40
F4 Software Architecture
Setup Page
Main Page____
Go to Operations
>Go to Setup
Go to Factory
Controller functional configuration
System settings
PID units, F or C, auto tune SP,
sensor failure, open loop, transfer power levels
Inputs; analog and digital
Outputs; control, alarm, communications, retransmit
Custom main page; selections
41
F4 Software Architecture
Factory Page
Set lockout
Change password
Main Page____
Go to Operations
Go to Setup
>Go to Factory
Diagnostics
Date code, software revisions, etc.
Calibration data
42
F4 Temperature/Process
Standard Operation
Open or closed loop operation
Automatic,
closed loop control
Control action responds to differences in
set point value
and process value
Manual,
open loop operation
Control actions responds to manual
changes to the controller output power
levels.
43
F4 Temperature/Process
Standard Operation
Five heat cool PID sets
Four
crossover points
programmable in the
operations menu
Crossover based on
set point or process
value
44
F4 Temperature/Process
Standard Operation
Auto/manual control operation
Manual
to auto transition
Based
on the last set point
Based on set point tracking (reverse bumpless)
Auto
to manual operation
System
menu choices for heat/cool transfer power levels
45
F4 Temperature/Process
Standard Operation
Single or multi-point offset feature
Single-point
Linear
across entire operating span
Multi-point
(10 points and offset values)
Points
can be positioned anywhere over the entire
operating span -19999 to 30000
Offset values are +/- 1000 units/degrees
Offset values are linearly interpolated between points
46
F4 Temperature/Process
Standard Operation
Digital set point feature
Four
namable set points
Activated
via the four digital inputs
Set point values are entered in the operations menu
Set point name and value appear on the main page
Values can not be adjusted from the main page
Digital set points have priority over local set point
47
F4 Temperature/Process
Standard Operation
Additional features
Process
outputs
Duplex
4
to 20 mA, 20 to 4 mA
Ramp
to set point
Ramp
Square
on start up/ramp on set point
root input linearization
48
F4 Temperature/Process
Standard Operation
Additional features
Custom
messages
4
user definable up to 50 characters
Activated by digital inputs
Displayed in main page
Tuning
Auto
feature
tune for heat only, cool only or heat and cool
49
F4 Temperature/Process
Standard Operation
Main Page
Displayable options
Local
or digital (namable) set point
Bar graphs
Set point, process value, output % power value
Tune status, active PID set
Digital input status
50
Creating a Part Number
Temperature/Process Controller
F4P X - X X X A - X X X X
Power Supply
Output 1A
Output 1B
Control Operation
(Standard or Enhanced)
RG Displays
Custom Options
Language Option
English, German
Spanish, French
Auxiliary Retransmit
51
F4P Feature Summary
F4P single channel
Single
channel PID
controller
1 universal analog input
4 digital event inputs
EIA232/485 comms
2 alarm outputs
52
Reasons to Buy
Usability
High
definition
display
Information key
Guided set Up
and programming
53
Reasons to Buy
Reliability
ISO
9001
manufacturing
Three year warranty
54
Reasons to Buy
Performance
Control
accuracy
Extensive feature set
Exhaustive life &
qualification testing
Availability
4
day lead-time
55
Reasons to Buy
Support
Local
sales
specialists
Applications
engineering
support
Rapid field
returns department
56
Series F4P 1/4 DIN Process
and Temperature Controllers
57