Cooling Solutions Category Overview
Download
Report
Transcript Cooling Solutions Category Overview
Cooling
Category Presentation
All content in this presentation is protected – © 2008 American Power Conversion Corporation
Cooling
Cooling Solutions for the IT Environment
Room
Rack
InRoom™ Chilled Water
InRoom™ Direct Expansion
Room Air Distribution
Rack Air Distribution
InRack Direct
Expansion
Row
InRow® Chilled Water
InRow® Direct Expansion
InRow® Pumped
Refrigerant
Thermal Containment
Highest efficiency, predictable cooling from the closet to the data center
APC by Schneider Electric – Name - Date
Cooling
Cooling Solutions for the IT Environment
Cooling Distribution &
Piping
Chilled Water Distribution
Refrigerant Distribution
APC by Schneider Electric – Name - Date
Heat Rejection
Condensers
Chillers
Fluid Coolers
Cooling Solutions: Key Considerations
Ability to adapt to unknown variables including power
densities that are increasing and unpredictable
Elimination of hot spots within the room and the rack
Dynamic heat loads and virtualization
Minimize total cost of ownership
Ensure stable inlet temperatures to IT equipment at all levels
of the rack
Flexibility to add cooling as the demand increases
APC by Schneider Electric – Name - Date
Cooling Solutions: APC Capabilities
Scalable solutions capable of handling IT equipment heat loads
from 1 to 30 kW per rack
Intelligent monitoring and dynamic controls system to adjust to
fluctuating IT heat loads and airflow requirements
Efficiently address data center cooling needs through the
implementation of a hybrid architecture
Minimize TCO through variable fan technology and right-sized
components
Heat removal at the source to eliminate mixing and ensure
uniform inlet temperatures to the rack
APC by Schneider Electric – Name - Date
Room Cooling
APC by Schneider Electric – Name - Date
Key Customer Challenges and Solutions: Room Cooling
Key Challenge: Planning for all of the unknown variables that will
occur through the life of the IT environment.
Room Cooling products offer flexible cooling solutions
perfect for lower density racked and non-racked IT loads.
Environments
● Closet / Server Room
• Room Air Distribution products provide ventilation to quickly address
lower density heat problems.
• InRoom Direct Expansion products offer portable self contained
dedicated cooling for rapid deployment in areas where cooling was not
properly planned.
● Data Center
• InRoom Direct Expansion offers glycol, multi-cool, and economizer
options to address a wide range of application for the small to medium data
center.
• InRoom Chilled Water products offer a complete range of sizes and
options to efficiently address large data centers.
APC by Schneider Electric – Name - Date
Room Cooling
InRoom™ Chilled Water
Perimeter chilled water cooling for medium to large data
centers.
Up to 150kW
InRoom™ Direct Expansion
Perimeter and portable cooling for wiring closets, server
rooms, and data centers.
Up to 86kW
Room Air Distribution
Air ventilation for wiring closets.
Up to 3.5kW
APC by Schneider Electric – Name - Date
Rack Cooling
APC by Schneider Electric – Name - Date
Key Customer Challenges and Solutions: Rack Cooling
Key Challenge: Insufficient airflow or cooling within a rack
caused by higher density IT equipment.
Rack Cooling products offer dedicated cooling and air
distribution for single racks or hot spots.
Environments
● Closet / Server Room
• Rack Air Distribution products provide solutions to address non
uniform airflow within racks caused by switches and other devices with
side to side airflow.
• InRack Direct Expansion provides a dedicated cooling system within
rack a contained rack isolating hot and cold air to improve efficiency and
predictability
● Data Center
Rack Air Distribution provide ventilation systems to improved cold air
distribution or heat removal to or from individual racks.
APC by Schneider Electric – Name - Date
Rack Cooling
Rack Air Distribution
Air distribution for power dense racks and low pressure areas.
Up to 16.5 kW
InRack Direct Expansion
Rack integrated cooling system for environmentally controlled
spaces.
Up to 7 kW
APC by Schneider Electric – Name - Date
Row Cooling
APC by Schneider Electric – Name - Date
Key Customer Challenges and Solutions: Row Cooling
Key Challenge: Keeping up with growing heat densities while
trying to reduce operational costs.
Row Cooling products offer energy efficient solutions for
low to high density racks and zones.
Environments
● Closet / Server Room
• InRow Direct Expansion products provide rapidly deployable self contained systems
to easily address areas where cooling was not planned.
• Thermal Containment provides rack level containment to isolate hot and cold air to
improve efficiency and predictability
● Data Center
• InRow Direct Expansion products are offered in air and fluid cooled options to
address a wide range of applications for the small to medium data center.
• InRow Chilled Water solutions are offered in several cabinet sizes, with and without
humidity control for large data centers.
• Thermal Containment is available in rack and aisle level configurations to address
racks, zones, or complete data center build outs to improve efficiency and predictability.
APC by Schneider Electric – Name - Date
Row Cooling
InRow® Chilled Water
Close-coupled, chilled water cooling for medium to large data
centers.
Up to 70kW
InRow® Direct Expansion
Close-coupled, air, water, and glycol cooling for closets, server
rooms, and data centers.
Up to 43kW
Thermal Containment
Air containment systems designed to maximize cooling
predictability, capacity, and efficiency.
APC by Schneider Electric – Name - Date
Cooling Distribution and Piping
APC by Schneider Electric – Name - Date
Key Customer Challenges and Solutions: Cooling
Distribution and Piping
Key Challenge: Improve flexibility to add cooling as demand
increases
Cooling Distribution products offer centralized distribution
and piping for rapid deployment of row cooling.
Environments
● Closet / Server Room
• Chilled Water Distribution offers flexible pipe kits for spaces where
chilled water is available.
● Data Center
• Chilled Water Distribution offers centralized distribution, jointless
PEX-AL-PEX piping, and insulation for complete distribution of chilled
water within the data center.
APC by Schneider Electric – Name - Date
Cooling Distribution and Piping
Chilled Water Distribution
Flexible chilled water and glycol distribution system for the
InRow cooling units
Supports up to 12 InRow RC unit
Cooling Distribution and Piping
Accessories
Options to optimize the distribution piping for InRow cooling
solutions
APC by Schneider Electric – Name - Date
Heat Rejection
APC by Schneider Electric – Name - Date
Key Customer Challenges and Solutions: Heat Rejection
Key Challenge: Ensuring reliable operation of the
entire cooling system
Heat Rejection products provide matched outdoor heat
removal for operation of room, row, and rack cooling
Environments
● Closet , Server Room, and Data Center
• Condensers offer matched heat rejection for InRoom and InRow
Direct Expansion products for air cooled applications
• Fluid Coolers offer matched systems for InRoom and InRow Direct
Expansion products for fluid cooled applications
• Chillers offer many sizes and features to address a wide range of
chilled water applications for any IT environment.
APC by Schneider Electric – Name - Date
Heat Rejection
Chillers
Water chilling plants for row and room cooling products.
5-220 kW
Condensers
Specifically engineered heat rejection for row and room cooling
products.
Fluid Coolers
Heat removal designed to use water or glycol for row and room
cooling products.
The Different Types of Air Conditioning Equipment for IT
59 Environments
APC by Schneider Electric – Name - Date
The APC Differentiators
APC provides air distribution, portable cooling and precision air
conditioning for all IT equipment cooling needs
Designed for cooling and heat removal in low power to high
density environments at the rack, row, and room level
Ease of use with integrated management for multiple platforms
Serviceable components with few single points of failure for high
availability
Ease of integration with entire APC portfolio
Highest efficiency, predictable cooling from the closet to the data center
APC by Schneider Electric – Name - Date