The CMS Trigger
Claudia-Elisabeth Wulz
Institute for High Energy Physics, Vienna
LHC Days in Split
10 Oct. 2002
Cross Sections and Rates
Cross sections for different
processes vary by many orders
of magnitude
• inelastic:
• W -> ln:
• tt:
• Higgs (100 GeV):
• Higgs (600 GeV):
109 Hz
100 Hz
10 Hz
0.1 Hz
0.01 Hz
Required selectivity
1 : 10 10 - 11
Trigger
C.-E. Wulz
2
Split, Oct. 2002
Principle of Triggering
T(
)
Event accepted?
YES
NO
Successive steps
Depends on
Event type
Properties of the measured trigger objects
e/g, m, hadronic jets,t-Jets,
missing energy, total energy
Trigger conditions: according to physics and technical priorities
Trigger objects (candidates):
C.-E. Wulz
3
Split, Oct. 2002
CMS Detector (Compact Muon Solenoid)
C.-E. Wulz
4
Split, Oct. 2002
Trigger Levels in CMS
Level-1 Trigger
Macrogranular information from calorimters and
muon system (e, m, Jets, ETmissing)
Threshold and topology conditions possible
Latency: 3.2 ms
Input rate: 40 MHz
Output rate: up to 100 kHz
Custom designed electronics system
High Level Trigger (several steps)
More precise information from calorimeters, muon
system, pixel detector and tracker
Threshold, topology, mass, … criteria possible as
well as matching with other detectors
Latency: between 10 ms and 1 s
Input rate: up to 100 kHz
Ouput (data acquisition) rate: approx. 100 Hz
Industral processors and switching network
C.-E. Wulz
5
Split, Oct. 2002
Conventional Concept with 3 Steps
Investment in
specialized
processors,
control
C.-E. Wulz
6
Split, Oct. 2002
CMS Concept with 2 Steps
Advantages:
Fewer components, scalable
Investment in
band width and
commercial
components
C.-E. Wulz
7
Split, Oct. 2002
Evolution of Trigger Requirements
ATLAS/CMS:
Rather high rates and large event sizes
Interaction rates:
~ Factor 1000 larger than at LEP,
~ Factor 10 larger than at Tevatron
C.-E. Wulz
88
Split,
Split,Oct.
Oct.2002
2002
Level-1 Trigger
Only calorimeters and muon system involved
Reason: no complex pattern recognition as in
tracker required (appr. 1000 tracks at 1034 cm-2s-1
luminosity), lower data volume
Trigger is based on:
Cluster search in the calorimeters
Track search in muon system
C.-E. Wulz
9
Split, Oct. 2002
Architecture of the Level-1 Trigger
GLOBAL TRIGGER
Global Calorimeter
Trigger
Regional Calorimeter
Trigger
Local Calorimeter
Trigger
Calorimeter
cell energies
C.-E. Wulz
Global Muon Trigger
Regional DT
Trigger
Regional CSC
Trigger
Local DT
Trigger
RPC
Trigger
Local CSC
Trigger
DT Hits
CSC Hits
10
RPC Hits
Split, Oct. 2002
Strategy of the Level-1 Trigger
Local
• Energy measurement in single calorimeter cells or groups of cells (towers)
• Determination of hits or track segments in muon detectors
Regional
• Identification of particle signature
• Measurement of pT/ET (e/g, m, hadron jets, t-jets)
• Determination of location coordinates (h,f) and quality
Global
• Sorting of candidates by pT/ET, quality and retaining of the
best 4 of each type together with location and quality information
• Determination of SET, HT, ETmissing, Njets for different thresholds and h ranges
• Algorithm logic
• thresholds (pT/ET, NJets)
• geometric correlations
- e.g. back-to-back events, forward tagging jets
- more detailed topological requirements optional
- location information for HLT
- diagnostics
C.-E. Wulz
11
Split, Oct. 2002
Level-1 Calorimeter Trigger
Goals
Identify electron / photon candidates
Identify jet / t-jet candidates
Measure transverse energies (objects, sums, missing ET)
Measure location
Provide MIP/isolation information to muon trigger
C.-E. Wulz
12
Split, Oct. 2002
Local / Regional Electron/Photon Trigger
Trigger primitive generator (local)
Flag max of 4 combinations
(“Fine Grain Bit”)
Regional calorimeter trigger
ET cut
Hit
+max of
Longitundinal cut hadr./electromagn. ET
/
Hadronic and electromagnetic isolation
< 2 GeV
< 1 GeV
f
Electron / photon
h
C.-E. Wulz
< 0.05
One of
e/g
Jet
> ET threshold
13
Split, Oct. 2002
Typical e/g Level-1 Rates and Efficiencies
• Single isolated e/g rate at 25 GeV threshold: 1.9 kHz
• 95% efficiency at 31 GeV
C.-E. Wulz
14
Split, Oct. 2002
Jet / t Trigger
Jet ET is obtained from energy sum of 3 x 3 regions sliding window technique, seamless coverage up to |h| < 5
Up to |h| < 3 (HCAL barrel and endcap) the regions are 4 x 4 trigger towers
Narrow jets are tagged as
t-jets in tracker acceptance
(|h| < 2.5) if ET deposit
matches any of these patterns
{
C.-E. Wulz
15
Split, Oct. 2002
Typical Level-1 Jet Rates and Efficiencies
• Single jet rate at 120 GeV threshold: 2.2 kHz, 95% efficiency at 143 GeV
• Dijet rate at 90 GeV: 2.1 kHz 95% efficiency at 113 GeV
• Single t-jet rate at 80 GeV threshold: 6.1 kHz
C.-E.
C.-E.
Wulz
Wulz
16 16
Split,
Split,
Oct.
Oct.
2002
2002
HT Trigger
HT, which is the sum of
scalar ET of all high ET
objects in the event is more
useful than total scalar ET
for the discovery or study
of heavy particles (SUSY
sparticles, top):
•
•
•
Total scalar ET integrates too much
noise and is not easily calibrated
– At Level-1 tower-by-tower ET
calibration is not available
However, jet calibration is
available as f(ET, h, f)
Implemented in Global
Calorimeter Trigger
• Rate with cutoff at 400 GeV: 0.7 kHz, 95% efficiency at 470 GeV
C.-E. Wulz
17
Split, Oct. 2002
Muon Trigger Detectors
Drift Tube Chambers and Cathode Strip Chambers are used for precision
measurements and for triggering.
Resistive Plate Chambers (RPC’s) are dedicated trigger chambers.
C.-E. Wulz
18
Split, Oct. 2002
Local Muon Trigger
Drift Tube
Chambers
Cathode Strip
Chambers
Superlayer
Vector of 4 hit cells
Comparators allow resolution of
1/2 strip width
Station
Correlator combines vectors
to track segment
C.-E. Wulz
6 hit strips
form track segment
19
Split, Oct. 2002
Regional DT/CSC Muon Trigger (Track Finder)
Trigger relies on track segments pointing to the vertex and correlation of several
detector planes
• Tracks with small pT often do not point to the vertex
(multiple scattering, magnetic deflection)
• Tracks from decays and punchthrough do not point to vertex in general
• Punchthrough and sailthrough particles seldom transverse all muon detector
planes
C.-E. Wulz
20
Split, Oct. 2002
Regional DT/CSC Muon Trigger (Track Finder)
Track Segment and direction of extrapolation
Longitudinal
plane
Bending
plane
Drift Tube Trigger
(CSC Trigger similar)
C.-E. Wulz
21
Split, Oct. 2002
Regional RPC Muon Trigger
RPC-Trigger is based on strip hits
matched to precalculated patterns
according to pT and charge.
4/4
High
pT 3/4
For improved noise reduction algorithm
requiring conincidence of at least 4/6 hit
planes has been designed. Number of
patterns is high. FPGA solution
(previously ASICs) seems feasible, but
currently expensive. Solutions to reduce
number of patterns under study.
C.-E. Wulz
Low 3/4
pT
4/4
22
Split, Oct. 2002
Global Muon Trigger
DR/CSC/RPC: combined in Global Muon Trigger
Optimized algorithm (no simple AND/OR) with respect to
• efficiency
-> Make use of geometry + quality
• rates
• ghost suppression
C.-E. Wulz
23
Split, Oct. 2002
L1 Single & Di-Muon Trigger Rates
Trigger rates in kHz
|h| < 2.1
18, 8;8
eW
=84.9 %
eZ
=99.7 %
eBsmm = 7.2 %
20, 5;5
eW
=82.3 %
eZ
=99.7 %
eBsmm =15.1 %
14, -;eW
=89.6 %
eZ
=99.8 %
eBsmm =27.1 %
25, 4;4
eW
=74.2 %
eZ
=99.5 %
eBsmm =18.4 %
working points compatible with current L1 pT binning
L = 1034cm-2s-
L = 2x1033cm-2s-1
C.-E. Wulz
24
1
Split, Oct. 2002
Global/Central Trigger within ATLAS and CMS
Algorithm
bits
Algorithm
bits
Thresholds already set in calorimeters
and muon system. The Central Trigger
Processor receives object multiplicities. It
does not receive location information,
therefore topological conditions are
impossible. Separate RoI electronics for
the Level-2 Trigger is necessary.
C.-E. Wulz
Thresolds set in Global Trigger. The
processor receives objects with location
information,
therefore
topological
conditions are possible. Special HLT
algorithms or lower thresholds can be
used for selected event categories. Sorting
needs some time, however.
25
Split, Oct. 2002
Global Trigger
The trigger decision is taken according to similar criteria as in data analysis:
• Logic combinations of trigger objects sent by the Global Calorimeter Trigger and the
Global Muon Trigger
Best 4 isolated electrons/photons
Best 4 non-isolated electrons/photons
Best 4 jets in forward regions
Best 4 jets in central region
Best 4 t-Jets
Total ET
Total ET of all good jets
Missing ET
12 jet multiplicities
Best 4 muons
ET, h, f
ET, h, f
ET, h, f
ET, h, f
ET, h, f
SET
HT
ETmissing, f(ETmissing)
Njets (different ET thresholds and h-regions)
pT, charge, f, h, quality, MIP, isolation
• Thresholds (pT, ET, NJets)
• Optional topological and other conditions (geometry, isolation, charge, quality)
C.-E. Wulz
26
Split, Oct. 2002
Algorithm Logic in Global Trigger
Object Conditions
eis.(1)
ET(1) > ET(1)t hreshold
ET(2) > ET(2)t hreshold
0o Š f(1) < 360o
0o Š f(2) < 360o
170o Š |f(1) - f(2)| < 190o
eis.(2)
Logical Combinations
eis.
eis.
OR
ETmissing
ETmissing
ET (eis.) > ET(e is.)threshold ET missing > ETthreshold
m+(1)
m-(2)
pT (1) > pT (1)t hreshold
pT (2) > pT (2)t hreshold
0o Š f(1) < 360o
0o Š f(2) < 360o
170o Š |f(1) - f(2)| < 190o
ISO(1) = 1, ISO(2) = 1
MIP (1) = 1, MIP (2) = 1
SGN (1) = 1, SGN(2) = -1
m
m
Particle Conditions
for isolated electrons
pT(m) > pT(m)threshold
Particle Condition for
missing ET
AND
Particle Conditions
for muons
AND
OR
ALGORITHM AND-OR
128 flexible parallel running algorithms implemented in FPGA’s.
Trigger decision (Level-1-Accept) is a function of the 128 trigger algorithm bits (for
physics). 64 more technical algorithms possible.
C.-E. Wulz
27
Split, Oct. 2002
Bs -> mm: Example of Topological Trigger
Df- distributions
Dh similar.
Can ask for
opposite charges in
addition.
C.-E. Wulz
28
Split, Oct. 2002
Bs -> mm: Example of Topological Trigger
Topological conditions: Dh < 1.5, Df < 2 rad, opposite muon charges
Gain by topological conditions and requiring no threshold on second
muon with respect to working point 20; 5,5: 1 kHz rate, 7.8%efficiency
(15.1% without, 22.9% with cuts).
C.-E. Wulz
29
Split, Oct. 2002
High Level Trigger Goals
•Validate Level-1 decision
• Refine ET/pT thresholds
• Refine measurement of position and other parameters
• Reject backgrounds
• Perform first physics selection
Detailed algorithms:
see talks of A. Nikitenko (e/g,jets), N. Neumeister (m) and other talks related
to CMS physics and wait for DAQ/HLT TDR due Dec. 2002.
C.-E. Wulz
30
Split, Oct. 2002
High Level Trigger Challenges
Rate reduction
Design input rate: 100 kHz (50 kHz at startup with luminosity 2x1033 cm-2s-1),
i.e. 1 event every 10 ms. Safety factor of 3: 33 kHz (16.5 kHz).
Output rate to tape: order of 100 Hz
Reduction factor: 1:1000
Example of allocation of input bandwidth to four categories of physics objects
plus service triggers (1 or 0.5 kHz):
- electrons/photons (8 or 4 kHz)
- muons (8 or 4 kHz)
- t-jets (8 or 4 kHz)
- jets + combined channels (8 or 4 kHz)
Algorithms
The entire HLT is implemented in a processor farm. Algorithms can almost be
as sophisticated as in the off-line analysis. In principle continuum of steps
possible. Current practice: level-2 (calo + muons), level-2.5 (pixels), level-3
(tracker), full reconstruction.
C.-E. Wulz
31
Split, Oct. 2002
High Level Trigger and DAQ Challenges
Processing time
Estimated processing time: up to 1 s for certain events, average 50 ms
About 1000 processors needed.
Interconnection of processors and frontend
Frontend has O(1000) modules -> necessity for large switching network.
Bandwidth
Average event size 1 MB -> For maximum L1 rate need 100 GByte/s
capacity.
C.-E. Wulz
32
Split, Oct. 2002
Conclusions
• CMS has designed a Trigger capable of fulfilling physics and
technical requirements at LHC.
• The Trigger consists of 2 distinct levels. Level-1 is custom
designed, the HLT is implemented with industrial components.
• Prototypes of many Level-1 electronics boards exist.
• Integration and synchronization tests are scheduled for
2003/2004.
• The HLT/DAQ Technical Design Report is finalized and due to be
ready at the end of 2002.
C.-E. Wulz
33
Split, Oct. 2002
Acknowledgments
- my colleagues in CMS and at HEPHY Vienna, especially P. Chumney,
J. Erö, S. Dasu, N. Neumeister, H. Sakulin, W. Smith, G. Wrochna,
A. Taurok.
- to the Organizing Committee of LHC Days in Split for the invitation and
the enjoyable conference.
C.-E. Wulz
34
Split, Oct. 2002