GOT1000 - SoftGOT - GOT Link Function for GT15 and GT16
Download
Report
Transcript GOT1000 - SoftGOT - GOT Link Function for GT15 and GT16
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
GOT1000 Series
SoftGOT-GOT Link Function
for GT15 and GT16 series
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
SoftGOT-GOT Link function –
Remote Maintenance for GOTs!
• The SoftGOT-GOT link function
enables GT SoftGOT1000 to
connect the GOT via Ethernet.
• The function synchronizes
SoftGOT1000 data with GOT
project data and resource data.
• This function is available for:
(GT12 not supported yet)
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
System overview
Interlock operations with GOT
and SoftGOT
⇒ Prevent unexpected
behaviors!!
Up to 99 GOTs can
be monitored on a
single PC
Worksite
Office
Ethernet
HUB
GT15/
GT16
HUB
Operation
interlock
Data auto upload
SoftGOT
Serial/BUS/
Ethernet
QPLC
Automatically upload the project
data from connected GOTs
⇒ No need to create the project
data for SoftGOT!!
Note! FX PLCs will be supported in one of the next development steps (no schedule yet)
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Configuration (Connection Type)
1) QBUS/serial connection between GOT and PLC
SoftGOT reads/writes devices in a PLC via GOT.
(Ethernet Transparent Function)
Worksite
Ethernet
GT15/GT16
Read/write devices
via GOT
Office
SoftGOT
RS232/
RS422/
QBUS
QPLC
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Configuration (Connection Type)
2) Ethernet connection between GOT and PLC
SoftGOT reads/writes devices in a PLC by directly
connecting to the PLC via Ethernet, not via GOT.
Worksite
Office
GT15/GT16
SoftGOT
RS232/
RS422/
QBUS
Read/write devices
by directly connecting to PLC
QPLC
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Features
•Project data auto acquisition function
SoftGOT automatically acquires GOT screen data (project
data).
There is no need to create the project data for SoftGOT.
Data Auto
Acquisition
Function
•Alarm data auto acquisition function
SoftGOT automatically acquires the alarm data of GOT.
Alarms that are already restored before connecting to
SoftGOT can also be viewed.
In both functions, the data stored in SoftGOT will be
updated every time the SoftGOT is started up.
Operation
Interlock
•Operating authority
Either one of SoftGOT or GOT can be operable to prevent
the simultaneous operation from both sides that may
cause unexpected behaviors.
•Operating authority (only GOT side)
A mode to make only GOT operable.
Until this mode is cancelled on a GOT, SoftGOT is not
operable.
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Operation Interlock – Operating Authority
Interlock operations with SoftGOT and GOT to prevent
simultaneous operation on both sides.
GT15/
GT16
Worksite
Operation interlock
Office
SoftGOT
×
Operable (with
operating authority)
QPLC
Operation is prohibited on
the GOT that had
operating authority before.
Move
operating
authority
×
Not operable (no operating authority)
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
Not operable
(without operating
authority)
Obtain operating authority
on the operating authority
acquisition screen
Operable (with operating authority)
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Operation Interlock – Operating Authority
Provides a mode to operate PLC only by GOT to prevent
the operating authority from being moved to SoftGOT.
If operating authority is enabled…
Worksite
GT15/
GT16
Operation interlock
Office
SoftGOT
×
QPLC
Operable
Not operable
• Not operable until GOT cancels the
operating authority priority
• SoftGOT cannot enable/cancel the
operating authority priority
The operating authority can be enabled/cancelled only on the GOT
side by using switches or utility functions on the GOT.
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Required Hardware
• All GT15 models
plus GT15-J71E71100 Ethernet
module
• All GT16 models
using integrated
Ethernet port
• Any Q CPU (only Q!)
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Required Software
• GT Works 3 V1.10L with
– GT Designer 3 V1.10L
– SoftGOT1000 3.10L
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
OS Installation -> GT15/GT16
• Transfer
extended
OS into
GOT!
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
GT Designer 3 Project Settings
Decide how to use the SoftGOT:
1. GOT and SoftGOT should always
show the same screen:
Use PLC Register (D) as Screen
switching device!
2. SoftGOT should act as separate HMI
showing different screens as GOT:
Use GOT Register (GD) as Screen
switching device!
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
SoftGOT settings
• Start SoftGOT1000
and open
Communication
settings
QCPU serial or QBUS connection
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
QCPU Ethernet connection
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
SoftGOT settings
1. Test GOT Link
Make sure to enter the IP-address
of the GOT (not the PLC!)
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
SoftGOT settings
2. Start Monitor
3. SoftGOT will
work for 2h
without dongle!
4. GOT project
will be uploaded
to SoftGOT
automatically!
5. Monitoring will
start
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Good to know!
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Good to know!
• Use internal GOT devices to control
operation method effectively!
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Manual references
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
This is the first time to have an
Ethernet Remote Maintenance
function in the GT15/GT16!
Let’s got out to customers
promoting and selling it!
Thank you for your attention
Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010