Surveying a Level Loop - Mr Desantis | TZHS Engineering

Download Report

Transcript Surveying a Level Loop - Mr Desantis | TZHS Engineering

Surveying a Level Loop
Level Loop
Instrument
location (TYP)
(or Closed Circuit)
FS 4.26 ft
1
Elev. 100.00 ft
Turning Point
(TYP)
Closed Circuit or Level Loop
AUTO LEVEL READINGS
STADIA
PT
(+)
BS
BM
7.13
TP-1
HI= Elev + BS
HI
(-)
FS
ELEV
107.13
X
100.00
4.26
102.87
TOP/BOT
STADIA
DIST
/Angle
Elev= HI-FS
Level Loop
(or Closed Circuit)
2
Elev. 100.00 ft
Turning Point
Elev. 102.87
Closed Circuit or Level Loop
AUTO LEVEL READINGS
STADIA
PT
(+)
BS
BM
TP-1
TBM
HI= Elev + BS
HI
(-)
FS
ELEV
7.13
107.13
X
100.00
1.75
104.62
4.26
102.87
2.99
101.63
TOP/BOT
STADIA
DIST
/Angle
Elev= HI-FS
Level Loop
(or Closed Circuit)
Elev.
101.63 ft
3
Elev. 100.00 ft
5
4
Closed Circuit or Level Loop
AUTO LEVEL READINGS
STADIA
PT
(+)
BS
HI
(-)
FS
ELEV
BM
7.13
107.13
X
100.00
TP-1
1.75
104.62
4.26
102.87
TBM
5.62
107.25
2.99
101.63
TP-2
0.94
102.18
6.01
101.24
TP-3
9.12
103.32
7.98
94.20
3.34
99.98
POR
HI= Elev + BS
TOP/BOT
STADIA
DIST
/Angle
Elev= HI-FS
Closure Error
The difference between a measured or
calculated elevation and the true or
established elevation.
Closure Error = Final Elev. – Initial Elev.
Closed Circuit or Level Loop
AUTO LEVEL READINGS
STADIA
PT
(+)
BS
HI
(-)
FS
ELEV
BM
7.13
107.13
X
100.00
TP-1
1.75
104.62
4.26
102.87
TBM
5.62
107.25
2.99
101.63
TP-2
0.94
102.18
6.01
101.24
TP-3
9.12
103.32
7.98
94.20
POR
3.34
99.98
- 100.00
CLOSURE ERROR = - 0.02 ft
TOP/BOT
STADIA
DIST
/Angle
Closed Circuit or Level Loop
AUTO LEVEL READINGS
STADIA
PT
(+)
BS
HI
(-)
FS
BM
7.13
107.13
X
TP-1
1.75
104.62
4.26
TBM
5.62
107.25
2.99
TP-2
0.94
102.18
6.01
TP-3
9.12
103.32
7.98
POR
3.34
ELEV
TOP/BOT
STADIA
100.00 BS 8.63 / 5.63
102.87 FS 5.69 / 2.83
BS 3.15 / 0.25
101.63 FS 4.44 / 1.54
BS 6.67 /4.57
101.24 FS 7.08 / 4.94
BS 1.84 / 0.04
94.20 FS 8.94 / 7.02
BS 10.42 / 7.82
DIST
/Angle
300 ft
286 ft
290 ft
290 ft
210 ft
214 ft
180 ft
192 ft
260 ft
248 ft
99.98 FS 4.58 / 2.10
- 100.00
TOTAL = 2470 ft
CLOSURE ERROR = - 0.02 ft
Level Loop
(or Closed Circuit)
Instrument
location (TYP)
Elev.
101.63 ft
3
Elev. 100.00 ft
5
4
Allowable Error
• The allowable error depends on the type
and purpose of the surveying.
• In this class, we will use
Reducing Errors
• Check that bubble is centered for EVERY rod
reading.
• Keep the rod plumb during each reading.
• Establish equal BS and FS reading distances.
– Equal reading distances will cancel out any error
caused by the line of sight not being parallel with the
axis of the bubble tube.
– This is not always possible due to terrain.
Common Errors
•
•
•
•
Faulty rod reading (verify reading)
Rod not fully extended (high reading)
Tripod movement during reading
Confusion between recording BS and FS
entries in the field book
Allowable Error
Survey data is acceptable