SCBA SmartDock.ppt

Download Report

Transcript SCBA SmartDock.ppt

SCBA Storage on
Rosenbauer Pumpers
View Spartan Chassis Sled Test video on Hendersonfireonline.com
Locations
Captain, FF/Paramedic, & FF all
located their respective seats
Engineer’s SCBA is in Comp 4
Engineer’s SCBA Deployment
• Open Compartment 4
• Press down on Yellow
tabs on both sides on
drawer.
• Slide out drawer until it
locks
• Grab handles and pull
down
Engineer SCBA Deployment
• Remove Retention
Strap
• Lift SCBA over
head and place on
your back
• Fold SCBA Bracket
back up.
• Slide Drawer back
into Comp 4
Stowing SCBA in Rosenbauer Engine
• Make sure all straps
are folded up and
contained inside
storage box.
• Press bottle firmly
into bracket
• Place retention strap
around SCBA
• Fold bracket plate
back up.
• Slide drawer back into
compartment.
IMMI GEN 2
SMARTDOCK SCBA BRACKET
Benefits
• Complies with NFPA 1901 to provide 9G
retention
• Deploys and stows easily
• Adjusts easily in the field
• No straps or levers for firefighters to
deploy
Smartdock Parts
Claw Assembly
Valve Retention Tab
Height Adjustment
CAUTION!!
Never cinch SCBA straps up while vehicle is in
motion. If shoulder straps are tight, SmartDock
will not retain bottle in the event of an accident.
Deployment
 Always wear seat belt when vehicle is in





motion
Place SCBA straps on shoulders
After arriving on scene cinch up straps on
shoulders
Lean forward
Stand up
SCBA bottle will automatically be released
from SmartDock
Daily Check and Stowing
View SmartDock SCBA Storage video on Hendersonfireonline.com
Troubleshooting
• Make certain claw
assembly works
smoothly everyday
during checkout
• Make sure bottle is
seated on valve
retention tab correctly
• Make sure height
adjustment is correct
(claw assembly should
barely touch top of
bottle – no more than
1/8” space.)
• Bottle heights may
vary slightly. Check
every time bottle is
put in bracket.