Transcript pptx
This is a special venue for me!
32
32
1
Time Domain Astronomy: The
Next Decade
S. R. Kulkarni
Caltech Optical Observatories
MAJOR DIVISION: VARIABLE
OBJECTS & TRANSIENTS
32
3
Variable Objects
• Key measurement: Light Curves
– Photometric Precision
• Low: RR Lyrae, Cepheids, AGN, Type Ia
• Moderate: Eclipsing Binaries, Gravitational Lensing
• High: Planetary Transits, Asteroseismology
• What is of value?
– Total number of visits usually matters more than
cadence
• Spectroscopy (followup)
– In most cases rapid follow up is not essential
– In many cases spectroscopy helps but is not crucial
32
4
Transient Objects
• Imaging surveys provide the starting point for investigation
– Supernova investigations are triggered by detection of a rising object
– For many studies the follow up is decoupled from the initial detection
of a GRB (at high energies)
• Cadence control is critical
– On the first night of an imaging survey the detected transients are
dominated by old supernovae
– Conversely lack of cadence control presents significant opportunity
costs (negative)
• Cadence directly determines the phase space that is being
explored
– “Universal” cadence simply means that everyone is equally unhappy
32
5
This Talk
• Focused entirely on transient object astronomy
• Main thesis:
– Transient object astronomy is served best by sharply focused time
domain surveys
– Conversely, the returns from a generic time domain survey are likely to
be quite poor (and wasteful of follow up resources)
• Transient Object Astronomy has a bright future in this decade and
likely to continue into the next decade (when TMT will become
operational)
– However, TMT time is precious
– Transient object astronomy has its own learning curve
– The TMT collaboration must start preparing now
32
6
AN EXEMPLAR
32
7
The Intermediate
Palomar Transient Facility (iPTF)
The Palomar Observatory
P60
P48
P200
32
9
P60
Confirmation
P48
Discovery
P200
Spectroscopy
32
10
32
Kasliwal 2011 (PhDT)
11
Super-luminous Supernovae
(no Hydrogen)
12
32
Death Omen!
PTF10tel
32
13
Double degenerates: The new frontier
Source: LISA Mission, NASA
32
14
ON TO LOW LATENCY
(SAME NIGHT)
32
15
32
16
Progenitor of a Ib Supernova!
32
17
What next?
S. R. Kulkarni
Short timescale is terra incognito
32
19
PTF11agg: Dirty Fireball?
32
20
Same night arcsecond localization of
error region of 72 square degrees!
32
21
As we go to press! GRB131011A
32
M. Kasliwal
L. Singer 22
•
TITLE: GCN CIRCULAR
NUMBER: 15324
SUBJECT: Fermi403206457: iPTF detection of a possible optical afterglow
DATE: 13/10/12 12:09:55 GMT
FROM: Mansi M. Kasliwal at Caltech/Carnegie <[email protected]>
M. M. Kasliwal (Carnegie Observatories/Princeton), L. P. Singer (Caltech) and S. B. Cenko
(NASA/GSFC) report on behalf of the intermediate Palomar
Transient Factory (iPTF) collaboration:
Starting 2013-10-12 05:26 UT, we imaged about 70 deg^2 in the vicinity of the localization of
the Fermi-GBM trigger 403206457 with the Palomar 48-inch Oschin telescope (P48). Sifting
through 10,816 candidate variable sources in the GBM error circle using standard iPTF vetting
procedures including Palomar 60-inch follow-up, we identify iPTF13dsw as a possible
optical afterglow candidate:
RA(J2000) = 02h 10m 06.38s
DEC(J2000) = -04d 24' 40.3"
Light Curve: R=19.7mag @ 05:26 UT (P48), R=20.2mag @ 08:07 UT (P60)
iPTF13dsw is 3.4 deg away from the center of the final GBM localization
(68% statistical confidence radius of 2.75 deg). Nothing was detected at
this location to a limiting magnitude of 20.6 mag on 2013 Sep 25.
At 08:56 UT, we obtained a Gemini-South/GMOS spectrum in twilight. The
spectrum is mostly featureless, with no prominent emission or absorption
lines between 5100-9300A.
.
32
23
WHAT IS THE METRIC OF SYNOPTIC
SURVEYS?
32
24
Proposed Metrics
• The “Reach” Etendue, AΔΩ
• Point source sensitivity, AΔΩ/θ2
• These metrics make sense only for static surveys.
• Not relevant for transient surveys
• For transients mere detection in itself is limited
value
• Classification and follow up is the key
32
25
Fundamental Parameters of a Time
Domain Survey (Transients)
•
•
•
•
Field-of-view (FOV), ΔΣ
Sensitivity (6σ), Sl
Time to move one FOV, τm
Cadence: typical time separation between revisit to the same FOV
• Basic Integration time, τs (frame time)
– Assume 60-s for all surveys
32
26
Areal Rate
• Short Duration Transients (T<τs)
• Long Duration Transients (T>τs)
• If follow up is essential then all that matters is Sl (set by
follow up) and the parameters shown above. For 21mag ZTF is 250 times faster than say HSC.
32
27
Zwicky Transient Facility
47-sq degree camera for P48
32
29
The SED Machine for P60
30 arcsec
7 arcminute
PI: Nick Konidaris, PS: Robert Quimby
In collaboration with
32 NCU-Taiwan
30
A Proposal: TMT Community based
Transient Object Facilities
• Recognizing that transient object astronomy is a
growing field with great promise the TMT
community should ensure that it has access to
quality transients
• Transient searches have three fundamental
parameters and as such the idea that a single
facility (equipped with “Universal Cadence”) can
provide the transient stream is incorrect
• The preparation for this should start now so that
the event streams will be ready by 2022.
32
31
ZTF Annual Workshops
• The ZTF consortium will be holding yearly
meetings (along the lines of the very
successful iPTF 2013 Workshop)
– We plan to invite key players from TMT
consortium to attend these meetings
• http://ptf.caltech.edu/iptf/iptf_workshop/
32