מצגת ללקוחות IH-1000, ינואר 2010
Download
Report
Transcript מצגת ללקוחות IH-1000, ינואר 2010
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
Welcome to the Future
Fully automated blood grouping system IH-1000
IH-1000 The Ideal Solution for
Immunohematology
IH-1000 combines three important features which are significant
both for today and the future:
Highest level of security and flexibility with full automation
Fast sample processing with continuous access
Cost efficiency
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
A Revolution in Immunohematology
The IH-1000 device is a revolutionary instrument for
immunohematological diagnostics, which can be used to execute
any type of test procedure.
The device can easily be connected to a host system and due to the
flexible software with intelligent robotics, samples can be processed
in any desired sequence.
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
More Than Just a Routine Machine
IH-1000 is both a routine and an emergency appliance. The robotics
and sample throughput design is such that samples can be added at
any time whilst the routine samples continue to be processed.
The status of a sample can be checked on the 17“ screen and the
device automatically indicates when the results will be available.
IH-1000 can also be accessed from remote computer consoles,
allowing the status of the process to be monitored and for validation
of sample results.
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
A Ground-Breaking
Immunohematological Device
IH-1000 has the capacity to stock reagent supplies of 240 ID-Cards,
28 vials of test cells and diluents as required.
Depending on the test profile chosen, the instrument processes
without re-stocking of reagents for an average of 6-9 hours.
The instrument automatically shows the level of the reagent supplies
and additional reagents can be introduced at any time.The status of
the supplies can be checked on the device itself or from a remote
location, for example from a Wi-Fi connection.
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
Overview
Walk away
Stand alone instrument
Continuous sample loading
Continuous reagent loading
Priority samples (STAT)
Reagent stock
High throughput
Optimized for small blood volumes
Dispense verification
Easy-to-use
Full test menue
Wi-Fi
Touchsreen 17“
Host connectivity
Internal & external validation
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
A detailed look at
IH-1000
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
A detailed Look at IH-1000
Fully-automatic walk away system for ID-Cards
Reagent stock for 240 ID-Cards, 28 test cells and diluent solutions
Capability for up to 180 sample tubes
Autonomy for 6-9 hours on average
Real walk-away system for at least 2-3 hours
Throughput up to 720 test per hour (~ 120 ID-Cards)
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
A detailed Look at IH-1000
Continuous loading of reagents (without interruption)
Continuous loading of samples (without interruption)
Continuous refilling of system liquid (without interruption)
Continuous loading of real time emergency samples at any time
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
A detailed Look at IH-1000
Automated maintenance steps
Integrated back-up systems
Built-in computer with 17“ touchscreen
Validation at the device and/or on one or more remote computers
Wi-Fi connection for wireless computer connection possible
Size (wide x depth x height): 180 x 82 x 170 cm
Weight approx. 560 kg
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
3 Steps to Success
Step 1:
Cards
Loading
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
3 Steps to Success
Step 2:
System Liquids
and Waste
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
3 Steps to Success
Step 3:
Sample & Reagent
Loading
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
3-2-1 Auto Start
No start button necessary
Auto start function
As soon as samples and reagents are on-board the system starts
automatically
Sample by sample processing (first in – first out)
Therefore:
Emergency sample processing always possible (no waiting time to start)
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
The working horse
2 independant pipetting stations
3rd arm only for card transport
3 centrifuges
Automated maintenance steps
Automatic tube diameter
detection
Automatic tube decap check
Re-using partial used cards
Integrated back-up system
(pipettors and centrifuges
compensate each other)
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
Intelligent Sample Handling
Different tube diameters can be used on the same rack
Automatic detection of the tube diameter
Automatic check for cap removal
Low volume optimization (min. volume 100µl)
Possibility for pediatric samples (tube in tube technology)
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
Key features
Easy access design
Minimum training required ( installation + training ~ 3 hours)
Integrated sample preparation table
Real stand-alone system
Real emergency function
No system stop while maintaining system liquids
Integrated back up system
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
Automation with Flexibility
Blood grouping
Reverse grouping
Phenotyping
Crossmatching
Antibody screening
Antibody identification
Direct AHG test (DAT)
Single antigens
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
Bio-Rad Laboratories
IMMUNOHEMATOLOGY
Welcome to the Future