Module 8 - 70861 - University of Southern Queensland
Download
Report
Transcript Module 8 - 70861 - University of Southern Queensland
Wastewater Treatment
On completion of this module you should be:
Aware of the public health aspects and goals of
wastewater treatment
Able to define the design flows to a wastewater treatment
plant
Able to describe and discuss the processes involved in
primary, secondary and tertiary treatment
Able to compare the differences between the fixed-film
and suspended growth systems in biological treatment
Able to discuss the methods available for nutrient removal
Module 8
1
Wastewater Treatment
Public health aspects of wastewater treatment
3.4 million people, mostly children, die annually from waterrelated diseases
2.4 million people lack access to basic sanitation include the
poorest in the world
1.1 billion people lack access to even improved water sources
Access to safe water supply and sanitation is fundamental for
better health, poverty alleviation and development (WHO data)
Module 8
2
Typical Characteristics of
Wastewater
Oxygen demand, BOD5 mg/L
200 - 400
Total suspended solids mg/L
200 - 300
Nitrogen mg/L
20 - 30 as NH3
30 - 70 total
Phosphorus, mg/L
8 - 16 total
Total dissolved solids, mg/l
400 - 600
Toxins eg metals, organics
Grease and oil
Total coliform number/mL
105 - 106
Fecal coliform, number/mL
104 - 105
Fecal streptococci number/mL
103 - 104
Enteric virus number/mL
10 - 102
Module 8
3
Wastewater Treatment Goals
Minimum capital cost
Reliable and economic operation
Protect public health from contamination of water
supplies
Removal of floating, suspended and soluble matter
Module 8
4
Wastewater Treatment Goals (cont)
Reduce BOD, COD, pathogenic organisms and
nutrient
Efficient collection system for aerobic conditions
Maintain aesthetics of natural water bodies, ecology
of water systems
Module 8
5
Treatment Selection
Wastewater treatment comprises primary,
secondary and tertiary treatments
The selection of appropriate treatment processes is
dependent upon the nature and strength of
pollutants, quantity of flow, and discharge licence
conditions
Module 8
6
Design Flows
Hydraulic loading
PWWF
Organic loading g/c.d
55 - 70 BOD5
70 -80 NFR or TSS
7 - 8 NH3 - N
Module 8
7
Primary Treatment
The first stage of wastewater treatment comprises
largely physical processes.
A well-designed primary treatment should remove
about 40 - 75% of TSS and about 25 - 40% BOD5
A possible pre-treatment is the injection of air, O2,
H2O2 and pre-chlorination if the influent is anaerobic
Processes include screening, grit removal and primary
settling
Module 8
8
Screens
The removal of large objects that may damage
pumps or block channels
Fixed or mechanical
Velocity in channels about 0.3 - 0.4 m/s
Velocity through openings about 0.6 - 1 m/s
All screenings to be removed/buried
Location of strong odour from decomposition
Module 8
9
Mechanical
bar screen
Module 8
10
Rotating drum screen
Module 8
11
Comminutors
These are mechanical cutting screens
that reduce the size of large objects
Shredded matter are returned to the flow
stream
A by-pass may be included
Module 8
12
Comminutor
Module 8
13
Grit Chambers
Purpose is to remove inorganic grit/sand 0.2 - 1 mm
size through differential settling
Aim is to prevent damage to pumps, blockage of
channels and cementing of sludge in settling tanks
Two types of grit chambers, namely constant velocity
and aerated/spiral flow tanks
Module 8
14
Constant Velocity Grit Chamber
Class I settling - horizontal flow
Uniform velocity at 0.25 - 0.35 m/s
Ideal parabolic shape or approximation
Width:depth ratio 1:1
Length 18 x max. depth
Module 8
15
Constant Velocity Grit Chamber
Module 8
16
Aerated or Spiral Flow Grit Chamber
Flexibility of control; more efficient grit removal and
can assist pre-aeration
Suitable for larger population > 10 000 ep
HRT of about 3 min at PWWF
Module 8
17
Aerated or Spiral Flow Grit Chamber
Module 8
18
Vortex Flow Grit Chamber
Module 8
19
Primary Sedimentation
Largely class II settling of flocculent matter and natural
coalescence or flocculation occurs
A test column is used to establish settling
characteristics and correction factor of 0.65 - 0.85 is
applied to overflow rate and 1.25 - 1.5 to detention
time values
Per cent removal = hn(Rn + Rn+1)/(2h)
The settled solids are pumped to an anaerobic
digestion tank. The effluent (settled sewage) from
primary treatment flows to the next stage i.e.
secondary treatment
Module 8
20
Primary Sedimentation
Per cent removed = dh1(R1 + R2)/(2h5) + dh2(R2 + R3)/(2 h5 ) + ...
Module 8
21
Some Features of Primary Settling
Design to accept 2 to 3 x ADWF
Removal of 40 - 75% suspended solids
Some incidental BOD5 reduction 25 - 40%
Hydraulic loading Q/A 30 m3/m2.d
HRT 1.5 to 3 h; depth 2.5 to 5 m
Even inlet distribution > 3 m/s
Sludge scrapers should not cause re-suspension
Module 8
22
Primary settling %
removed vs time
Module 8
23
Types of Primary Settling tanks
Rectangular horizontal-flow
Tanks use less space
Forward velocity 10 - 15 mm/s
Weir loading rate < 300 m3/m.d
Length:width ratio 3:1
Module 8
24
Rectangular horizontal-flow
Module 8
25
Types of Primary Settling tanks
Up-flow tank
Square with 60o sludge hopper
No moving parts as sludge is removed
hydrostatically
Some possible particle carry over
Module 8
26
Up-flow settling tank
Module 8
27
Types of Primary Settling tanks
Circular radial flow tank
Radial-horizontal flow
Uses radial scrapers to remove sludge
Module 8
28
Circular Radial Flow Tank
Module 8
29
Circular
Radial Flow
Tank
Module 8
30
Circular Radial Flow Tank
Module 8
31
Pulteney Bridge
and Weir, City of
Bath
Module 8
32
Secondary Treatment
Central process is biological in which
dissolved organics are utilised by
microorganisms
Hence, secondary treatment is often known
as biological treatment
The concomitant growth of biomass (cells)
and substrate removal must be followed by
separation
Module 8
33
Classification of Microorganisms
Microorganism
Energy source
Carbon source
Autotrophic
photoautotrophic
light
CO2
chemoautotrophic
inorganic oxidationreduction reaction
CO2
Heterotrophic
photoheterotrophic
light
organic carbon
chemoheterotrophic
organic oxidationreduction reaction
organic carbon
Module 8
34
Typical microorganisms in activated sludge
Module 8
35
Biological processes
Aerobic condition – presence of free
molecular oxygen
Anaerobic condition – devoid of free
molecular oxygen
Anoxic – absence of free molecular
oxygen but presence of nitrate
Module 8
36
Types of Metabolism
Respiratory metabolism
aerobic microorganisms generate energy by
enzyme-mediated electron transport from an
electron donor to an external electron acceptor
eg O2
anoxic process uses NO3- and SO42- as the
electron acceptors
Module 8
37
Types of Metabolism
Fermentative metabolism
anaerobic processes that do not involve an
external electron acceptor
process is less energy efficient and is
characterised by low growth rates and low cell
yield
facultative anaerobes can shift from fermentative
to aerobic respiratory metabolism depending on
the absence or presence of O2
Module 8
38
Some Concepts of Biological
Treatment
Biological growth curve
Food:microorganism ratio ie F/M
Fixed-film (attached) system and
suspended growth system
Module 8
39
Biological growth curve
Lag phase
Log-growth or exponential phase
Stationary phase
Log-death or endogenous phase
Module 8
40
3500
700
600
2500
500
2000
400
1500
300
COD
Biomass
1000
200
500
100
0
Biomass mg/L
COD mg/L
Biomass/COD vs time
3000
0
0
20
hours 40
60
80
Biomass growth and substrate removal curves
Module 8
41
F/M ratio
Food is the substrate i.e. (Q x S)
Microorganisms i.e. (reactor volume x
biomass conc.)
F/M is expressed as t-1
F/M is used as a preliminary design criterion
Module 8
42
Fixed-Film Systems
Land treatment, trickling and rotating
biological filters are predominantly
aerobic biological processes
Land treatment i.e. broadcasting of
sewage is one of the earliest forms of
wastewater treatment
Module 8
43
Trickling Filter
Development of a biofilm on an inert surface
where macro and microorganisms break down
organic matter
Natural sloughing of the biofilm owing to aerobic
growth, decay and shear stress at the interface
Filter medium voids promote air circulation and
aerobic condition
Module 8
44
Trickling Filter
Module 8
45
Trickling filters at Wetalla
Module 8
46
Interaction of biofilm
Module 8
47
Trickling Filter (cont)
Design for PWWF
Simplicity in construction but little control
Ease of operation but high initial capital cost
Balance of hydraulic and organic loading
necessary to prevent clogging of voids
Module 8
48
Trickling Filter (cont)
BOD removal efficiency E = 1/[1 + 0.44(W/VF)]
Speed of distributor is critical
Recirculation ratio 0.5 - 3
Humus sludge production 0.3 - 0.5 g/g BOD5
removed
Module 8
49
Rotating Biological
Contact Unit
A fixed-film aerobic process comprising of large
number of discs rotating half submerged in a tank
Wastewater flows through the tank
Development of biofilm on the disc that interacts
with the wastewater
The rotating biological contact units are compact
with low energy consumption
Module 8
50
A rotating
biological
contact unit
Module 8
51
Suspended Growth Systems
Microorganisms are held in suspension as a high
concentration flocculent, bulky matter through agitation,
stirring
The microorganisms interact with influent wastewater
and biodegrade organic matter into CO2, H2O and byproducts, releasing energy for growth of new cells
The activated sludge process is an example of an
aerobic suspended growth system. The anaerobic
digester for the break down of waste sludge is an
example of an anaerobic suspended growth system
Module 8
52
Activated Sludge Process
Influent (or settled sewage from primary treatment)
enters the reactor (aerator tank) where contaminants are
biodegraded by selected microorganisms
Reaction processes lead to the reduction of
contaminants and increase of biomass (cells)
In the activated sludge process the biomass is often
referred as the mixed liquor volatile suspended solids
(MLVSS)
MLSS is the mixed liquor suspended solids (MLVSS
0.8 MLSS)
Module 8
53
Activated Sludge Process (cont)
The biomass is separated in a final sedimentation tank
(clarifier) as settled sludge and recirculated as return
activated sludge (RAS) to the reactor
The clarified effluent is often of a standard that may be
discharged into receiving waters
The RAS increases the MLVSS concentration in the
reactor
To maintain a designed MLVSS (at steady state) some
biomass must be wasted
Module 8
54
Activated sludge process with alternative wasting locations
Module 8
55
Some Features of the Activated Sludge
Process
Design for PDWF and F/M ratio
System is aerobic; requires 0.5 - 2 mg/L DO using
diffused air, surface aerators, turbines
Microorganisms are mainly aerobic & facultative
heterotrophs and some autotrophs for nitrification.
Microorganisms are kept in suspension by mixing
Module 8
56
Some Features of the Activated Sludge
Process (cont)
Sludge recycle (RAS) is an essential part of the process.
Owing to recycle the HRT is not the same as the solids
retention time (SRT) or sludge age
Sludge age is controlled by wasting the correct mass of
sludge daily
c = X V/[Qw Xw + (Q - Qw)Xe]
Module 8
57
Some Features of the Activated Sludge
Process (cont)
Mixed liquor suspended solids (MLSS) is a mixture of
microorganisms and particulate matter
MLSS serves as a quantitative measure of activated
sludge concentration
Final clarifiers separate the MLSS from the treated
wastewater using class III and IV for settling and
thickening sludge
Clarifier tanks are usually circular 10 - 30 m dia. and
depth is important 4 - 4.5 m
Module 8
58
Some Features of the Activated Sludge
Process (cont)
Mixing regimes in reactor tanks may be plug flow or
completely mixed system
Several variations of activated sludge processes are
possible
These range from the conventional systems with high
F/M to extended aeration plants with low F/M
Better effluent quality from activated sludge plants
compared with trickling filters
Module 8
59
Hydraulic Characteristics of Reactor
Tanks
Plug flow system
Each element has the same residence time
Long and narrow in dimension
No longitudinal mixing
BOD highest at inlet
Module 8
60
Hydraulic Characteristics of Reactor
Tanks
Plug flow system (cont)
DO lowest at inlet
Lower average MLSS
Theoretically more efficient than completely mixed flows
Module 8
61
Hydraulic Characteristics of Reactor
Tanks
Completely-mixed system
Each element may not have the same HRT
Continuous and thorough mixing
Rectangular tanks, typically 6 -7 m width x 3-5 m depth
Uniform MLSS and BOD
Module 8
62
Hydraulic Characteristics of Reactor
Tanks
Completely-mixed system (cont)
Higher MLSS
Substrate concentration in tank and effluent are equal
Better resistance to shock hydraulic and pollutant loads
Better resistance to toxic loads
Module 8
63
In practice nonideal flow occurs
Module 8
64
Areas of short-circuiting and incomplete mixing
Module 8
65
Aeration
Two-film theory - a physical mass transport across
gas film and liquid film
For the transfer of gas molecules from the gas
phase to the liquid phase, slightly soluble gases
encounter the primary resistance from the liquid
film
Very soluble gases encounter the primary
resistance to transfer from the gaseous film
Module 8
66
Two-film gas-liquid transfer
Module 8
67
Aeration
devices
Module 8
68
Aeration (cont)
Aim of the aerator - to increase O2 transfer from
liquid film to the bulk liquid at a rate sufficient to
meet the O2 demands of metabolism
A major energy consuming process
KLa is the overall oxygen mass transfer coefficient.
It is a function of the equipment, tank geometry and
wastewater characteristics
Oxygen transfer rate, OTR = KLa C20 V kg O2/h
Module 8
69
Aeration (cont)
Typical transfer rate
Kg O2 /kW.h
efficiency
Diffused air
0.6 - 1.0
6 - 15%
Surface aerator
0.7 - 1.3
OTRfield =
Module 8
70
Dome diffuser
Module 8
71
Aeration (cont)
Function of O2 in activated sludge is a two stage process
Aeration provides the DO (electron acceptor) for aerobic
metabolism
DO of 0.5 - 2 mg/L is necessary for aerobic condition
Aeration must balance the oxygen uptake by the
microorganisms
Module 8
72
Surface brushes
Module 8
73
Surface aerators
Module 8
74
Floating surface aerator
Module 8
75
Separation of the treated wastewater
from the solids
Occurs after the biological or transformation
process
A physical process of settling generally in a
separate tank
In some processes this removal of solids can
also occur in the same tank but separated in
time
Module 8
76
Final Sedimentation Tank
A physical separation process to settle the
solids (microorganisms, particulate) from the
clarified effluent
Thicken sludge is returned to the reactor tank
Design for 3 x ADWF or PWWF
Class III and IV settlings; depth is relevant
Weir overflow rate < 250 m3/m.d
Module 8
77
Final sedimentation tank
Module 8
78
Hindered zonal settling
Module 8
79
Final clarifier
Module 8
80
Final Sedimentation Tank (cont)
Involves 2 important functions
Clarification
– Hydraulic loading must not exceed the
settling velocity of the slowest settling
particle
– vs = Q/A ie. 30 - 40 m3/m2.d for
activated sludge
– HRT 1.5 to 2 h
Module 8
81
Final Sedimentation Tank (cont)
Thickening capacity is based on the Solids Flux
theory
A concept of maximum quantity of solids that can be
handled by a settling tank at a given underflow
removal rate without affecting performance. It
involves the solids loading rate
GL = Q(1 + R)X/(1000A) kg/m2.d
Measuring the settleability of sludge, SVI
Module 8
82
Analysis of solids flux
Module 8
83
Sludge Volume Index (SVI)
A criterion for measuring the settleability of sludge
It is related to the recycling of activated sludge
SVI is defined as the settled volume of sludge
(mL/L) in 30 minutes per unit MLSS (mg/L)
SVI of 50 - 100 mL/g indicate good dense sludge
SVI > 150 mL/g are light, poorly compacting
(bulking sludge)
Module 8
84
Factors affecting SVI
Sewage composition; relationship between
zoogloeal and filamentous growth are
dependent on industrial wastes, carbohydrates
etc
Degree of longitudinal mixing in reactor tank;
plug flow is less prone to bulking
Anoxic conditions and nitrifying systems result in
low SVI
Module 8
85
Return Activated Sludge (RAS)
Rate of return, R = 100/[106 /(X.SVI) - 1]
Represents the underflow of the final
clarifier to the reactor tank
An essential feature of the activated sludge
system to maintain the desired MLSS
Rate of return activated sludge varies from
20 to 150% of ADWF
Module 8
86
Types of Activated Sludge Systems
Conventional activated sludge
Operates at F/M ratios of 0.2 to 0.5
Design to remove BOD and may also nitrify
Plug flow, limited longitudinal mixing, spiral flow along
tank through diffusers
Reactor tanks are long, narrow up to 150 m length;
W:D = 1:1 to 2.2:1; D = 3 to 5 m; W = 6 to 12 m
Limited resistance to shock and toxic loads
Module 8
87
Types of Activated Sludge Systems
Continuous extended aeration process
Systems operate with low organic loadings (F/M);
high c and high HRT
Process minimises sludge handling, consequently
have no primary sedimentation tanks
Increased endogenous respiration results in less
sludge, but increase O2 demand
Module 8
88
Types of Activated Sludge Systems
Continuous extended aeration process (cont)
Exhibits completely mixed; hence more stable to
fluctuations in flow and loading (organic); requires
less stringent recycle
Examples are continuous oxidation ditches eg.
carousels
Module 8
89
Types of Activated Sludge Systems
Module 8
90
A comparison of Activated Sludge
Systems
Conventional
Extended aeration
Large flows
Small flows
Plug flow
Completely mixed
HRT 4 – 8 h
HRT 18 – 36 h
F/M 0.2 – 0.4
F/M 0.04 – 0.15
Sludge age 5 – 15 d
Sludge age > 15 d
MLSS 1500 – 3000 mg/L
MLSS 3000 – 6000 mg/L
BOD removed 80 –90%
BOD removed 85 – 95%
R 0.25 – 0.5
R 0.75 – 1.5
Module 8
91
Continuous extended aeration process
Module 8
92
Intermittent Decanting Extended Aeration (IDEA)
Biological oxidation and final clarification occur in
the same tank: functions are only separated in time
Primary treatment is not necessary
Treated and clarified water is decanted intermittently
but raw sewage is fed continuously
Sludge is wasted during the aeration cycle to
maintain a constant MLSS of 3500 - 5000 mg/L
Module 8
93
Pasveer Oxidation Ditch
An example of the intermittent decanting extended
aeration process serving 500 to 2000 ep
4 hours operating cycle for normal operation; 3
phases per cycle controlled by an automatic timing
device
Aeration
Settling
Effluent decanting
Module 8
2.5 h
1.0 h
0.5 h
94
Major advantages of the IDEA process
Cheaper than continuous activated sludge
systems
Easily modified to remove nutrients
Easy operation and minimum attendance
Module 8
95
Disadvantages of the IDEA process
High operating energy requirements
Sludges are often difficult to settle
Not suitable for large flows
Module 8
96
Disinfection
Secondary treatment will remove up to 98% of
microorganisms and 105 - 107/100 mL of coliform remains
Chlorine remains the common disinfection agent
A contact time of 20 - 30 minutes is required
Much debate continues on the use of chlorine
Other environmentally friendly methods are
preferred such as:
UVL, ozone, membrane filtration, artificial wetlands
Module 8
97
Nano-membrane filtration
Module 8
98
Nutrient Removal
The major components of nutrients in wastewater
are nitrates and phosphates. They contribute to the
eutrophication of receiving water
Total nitrogen may be about 35 mg/L and total
phosphorus 8 mg/L after secondary treatment
Raw sewage composition of C:TN:TP 100:25:6
Normal plant growth only need C:TN:TP of
100:15:1
Module 8
99
Nitrification
In the nitrogen cycle, organic and ammonium
nitrogen are converted first to nitrite and then to
nitrate
Sources:
Organic nitrogen (40%)
Ammonium-nitrogen (NH4+–N 60%)
Nitrite-nitrogen (NO2—N)
Nitrate-nitrogen (NO3--N)
Module 8
100
Nitrification (cont)
Ammonia in wastewater is toxic to fish; it has a high
O2 demand; it increases Cl2 demand during
disinfection
Primary treatment removes < 20% influent nitrogen
Secondary treatment removes about 30% cumulative
Limit for ammonium-N in treated effluent < 2 mg/L
Module 8
101
Nitrification (cont)
Nitrification is a 2-stage process by different types of
aerobic autotrophic bacteria
NH4+ + (3/2)O2 = NO2- + 2H+ + H2O
NO2- + (1/2)O2 = NO3 Nitrifying bacteria are sensitive to toxic substances;
grow more slowly (high c); optimum temp 28-39oC
and decreases with low temp
Module 8
102
Nitrification (cont)
Operating pH 6.5 – 8
Nitrification reduces alkalinity (7.1 g of alkalinity as
CaCO3 is exhausted by 1 g NH4+-N) nitrified)
Nitrification is adversely affected by F/M > 0.4 – 0.6
Minimum DO 1.5 mg/L is required
Module 8
103
Denitrification
Conversion of nitrates (derived from nitrification) to
nitrogen gas
Denitrification is a type of respiration carried out by
facultative heterotrophs; a process known as anoxic as
NO3- is the terminal electron acceptor
Organic-C + NO3- = CO2 + H2O + OH- + N2 + energy
Alkalinity is increase but by about half the amount removed
by nitrification
Module 8
104
Denitrification (cont)
DO inhibits denitrification
A carbon source must be available (external or recycled
endogenous carbon)
Some BOD is removed but more slowly than aerobic
respiration
Denitrification can be induced in the anoxic part of fixed
growth systems by making the filter bed deeper (2.5 – 3 m)
but use of activated sludge is the normal process
Module 8
105
Denitrification (cont)
In conventional activated sludge, the anoxic zone within
the reactor tank may be 30 – 40% of volume and precedes
the aerobic zone
In carousel systems, the establishment of sequential
aerobic zones coupled with long HRT and high c promote
endogenous denitrification
Denitrification can be achieved in separate reactors using
suitable organic source
Module 8
106
Phosphorus Removal
Sources are from domestic wastewater, trade and
agricultural wastes; usually present in 3 forms
Orthophosphate (removed by chemical/or biological processes)
Polyphosphate
Organic phosphorus
Polyphosphate and organic phosphorus are less easily
removed until transformed to orthophosphate after
secondary treatment
Module 8
107
Phosphorus Removal (cont)
About 10% of insoluble phosphorus can be removed by
primary settling
Conventional biological treatment removes a further 15 35% by assimilation during biomass growth, but a well
designed BNR (biological nutrient removal) plant can
remove up to 95% of P
Almost all soluble phosphorus can be removed by
chemical precipitation
Module 8
108
Phosphorus Removal (cont)
Using chemical precipitation
Lime, Ca2+
Aluminium sulfate, Al3+
Ferrous sulfate (pickle liquor), Fe2+
Ferric chloride / ferric sulfate, Fe3+
Relative cost of coagulants, Al3+ > Fe3+ > Fe2+ > Ca2+
pH range for aluminium and iron salts 5.5 to 7
Module 8
109
Phosphorus Removal (cont)
A more efficient process is biological phosphorus removal
One example is the modified University of Cape Town
model (UCT) for biological nutrient removal
Denitrifying plants can be modified by a fermentation
zone at the head of the aeration tank
Selective growth of bacteria (acinetobacter) absorbs
the phosphorus
Daily wasting of activated sludge removes the stored
phosphorus
Module 8
110
Biological phosphorus removal
Modified Bardenpho process
Module 8
111
Biological phosphorus removal
Phosphate transport in and out of bacteria
Module 8
112
End of Module 8
Module 8
113