On Demand Presentation - News from American Water Heaters

Download Report

Transcript On Demand Presentation - News from American Water Heaters

RELIABILITY ON DEMAND
A COMPLETE LINE OF TANKLESS GAS WATER HEATERS
American On-Demand Gas Water Heaters
•
•
•
•
•
A full product line of tankless water heaters by American
Residential and Commercial applications
Interior and Exterior installation options
Natural Gas or Propane
16 different models covering a range of needs
1
Rely on American
• Benefit from the always reliable customer service of American and
the comfort of endless hot water.
• Combine the efficiency of the tankless technology with the expertise
of the American brand.
• Gain greater flexibility when it comes to controlling water
temperature in the home.
2
Reliable Technology
• On-board diagnostics and safety
monitoring
• Energy efficient - up to 84% thermal
efficiency
• Continuous hot water up to 9.8 GPM
(maximum flow rate)
• Direct electronic ignition; no pilot light
• 12-year limited warranty on heat
exchanger in residential applications,
5-year limited warranty on heat exchanger
in commercial applications; 5-year
warranty on all parts
• Up to 237,000 BTU maximum gas
consumption
• Natural gas or propane
3
Inspired Comfort
• All models come with a Standard
Temperature Controller that can
set the temperature within a
specific range and can provide
error codes to diagnose
problems.
• The Commercial Temperature
Controller can be used to
achieve temperatures above
140ºF, up to 160ºF for the 305
models and up to 185ºF for the
505 and 705 models.
Standard Temperature
Controller
Commercial Temperature
Controller
4
Remote Controller
In-Use Indicator Light
Indicates hot water is being
supplied (a tap is open)
Temperature Display
Shows the temperature
setting
Priority Indicator
Indicates that this controller is
setting the temperature
Error Codes
When a fault is detected
an error code flashes at
the temperature display
Priority Button
Priority can be changed to
another controller if desired
Thermostat
Increases/decreases
temperature setting
On/Off Button
Will turn the water heater on/off
5
On-Demand Models
305 Model Specifications
• Model Numbers:
– Interior: GT-305-NI and GT-305-PI
– Exterior: GT-305-NE and GT-305-PE
• BTU Input:
– Minimum 15,000/Maximum 180,000
• Flow Rate:
– 7.5 GPM Maximum
– 0.6 GPM Minimum
• Efficiency Rating:
– Indoor 84%/Outdoor 83%
• Weight:
– Indoor 50 lbs./Outdoor 46 lbs.
Exterior
7
Interior
505 Model Specifications
Exterior
Interior
• Model Numbers:
– Interior: GT-505-NI and GT-505-PI
– Exterior: GT-505-NE and GT-505-PE
• BTU Input:
– Minimum 15,000/Maximum 199,000
• Flow Rate:
– 9.4 GPM Maximum
– 0.6 GPM Minimum
• Efficiency Rating:
– Indoor 84%/Outdoor 83%
• Weight:
– Indoor 50 lbs./Outdoor 46 lbs.
8
705 Model Specifications
• Model number*:
– Interior: GT-705-NI and GT-705-PI
– Exterior: GT-705-NE and GT-705-PE
• BTU Input:
– Minimum 19,000/Maximum 237,000
• Flow Rate:
Interior
– 9.8 GPM Maximum
– 0.6 GPM Minimum
• Efficiency Rating:
– Indoor 84%/Outdoor 83%
• Weight:
*ASME models also available:
– 55 lbs.
Interior: AGT-705-NI and AGT-705-PI
Exterior: AGT-705-NE and AGT-705-PE
9
Exterior
Model Specifications Overview
Model
Number
BTU Input
Minimum
Natural/Propane
Maximum
Hot Water Output (GPM)
Maximum 45ºF Rise 70ºF Rise
Approximate
Shipping
Weight (lbs.)
Energy
Factor
(E.F.)
INTERIOR MODELS
GT-305-NI
15,000
180,000
7.5
6.6
4.3
50 lb.
.82
GT-505-NI
15,000
199,000/190,000
9.4
7.4/7.1
4.7
50 lb.
.82
GT-705-NI
19,000
237,000
9.8
8.8
5.7
55 lb.
N/A
AGT-705-NI* 19,000
237,000
9.8
8.8
5.7
55 lb.
N/A
EXTERIOR MODELS
GT-305-NE
15,000
180,000
7.5
6.6
4.3
46 lb.
.82
GT-505-NE
15,000
199,000
9.4
7.4
4.7
46 lb.
.82
GT-705-NE
19,000
237,000
9.8
8.7
5.7
55 lb.
N/A
AGT-705-NE* 19,000
237,000
9.8
8.7
5.7
55 lb.
N/A
*705A models are ASME Certified.
For Propane, change “N” to “P” in model number (e.g. ATI-305P).
All information above for 305 (200/201 Series) and 505 (200/201 Series)
10
Multi-System Options
• Connection cable or kits are available for multi-system integration.
Number of Connected Water Heaters:
Accessories Necessary:
2
(1) 2-Unit connection cable or (1) Multi-Unit connection kit
3
(1) Multi-Unit connection kit and (1) Multi-Unit connection cable
4
(1) Multi-Unit connection kit and (2) Multi-Unit connection cables
5
(1) Multi-Unit connection kit and (3) Multi-Unit connection cables
11
Sizing
Model Selection Guide
• To properly size On-Demand units for a home, two factors are of
critical importance . . .
1. Incoming ground water temperature
- Will determine the amount of “temperature rise” required to
achieve the desired hot water outlet temperature (120ºF is
recommended)
2. Peak hot water demand
- How much hot water the home will need during its busiest usage
period
13
Ground Water Temperature Factor
14
Peak Hot Water Demand
• Consider all the applications and fixtures in the home that use hot
water, including lavatory faucets, kitchen faucets, washing
machines, dishwashers, showers and bathtubs.
• Determine how many of these appliances and fixtures will be in use
at the same time during the busiest usage period.
– For example, if one kitchen faucet, one shower and a washing
machine are all in use during the busiest period, use the number
3 to make your selection from the Model Selection Guide.
15
Model Selection Guide
Appliances or fixtures
in simultaneous use
during peak demand
Ground Water Temperature Zone
Southern Zone
Central Zone
Northern Zone
1
305 or 505
305 or 505
305 or 505
2
305 or 505
305 or 505
305 or 505
3
505 or 705
(2) 505 or 705
(2) 505
4
(2) 505
(2) 505
(2) 505
5
(2) 505
(2) 705
(2) 705
6 or more
Multi-system
Multi-system
Multi-system
*Note: This Selection Guide is based on 120ºF outlet water temperature.
16
Energy Star® Qualified Models
Tax Credit
High efficiency water heaters are not just environmentally sound–over the course of their life-cycles,
they can also help homeowners save a lot of money. Due to a recent extension of residential tax
credits for energy-efficient improvements, several of our American On-Demand models are now
eligible for a tax credit of up to 30% (with a cap of $1,500) of the purchase and install price.
See americanwaterheater.com for more information
Technical Information
Outlet Flow Data
11
10
9
Water Flow (gpm)
8
7
305 (200)
6
505 (200)
5
705
4
3
2
1
0
0
10
20
30
40
50
60
70
80
ΔT - Temperature Rise (°F)
18
90
100
110
120
Dimensions – Interior Models
305/505 (200/201 Series)
20
705 Model
Dimensions – Exterior Models
305/505 (200/201 Series)
21
705 Model
Pipe Sizing
22
Piping for Basic Installation
Equipment List:
1 Water Heater
1 Plumbing Installation Kit (Optional)
2 Unions
2 Ball Valves
2 Drain Valves
1 Pressure Relief Valve
On-Demand
Water Heater
KEY
3/4″ Gas Connection
3/4″ Hot Water Supply
For Building Fixtures
Gas Supply
3/4″ Cold Water Supply
23
3/4″ Ball Value
Pressure Regulator
3/4″ Union
Circulating Pump
Check Value
Bolier Drain Valve
Pressure Relief Valve
Solenoid Valve
Flue Terminal Clearances – Interior Models
U.S.
DIM DESCRIPTION
Installations
A Clearance above grade, veranda, porch,
12″ (30 cm)
deck, or balcony
B Clearance to window/door that may be open 12″ (30 cm)
C Clearance to permanently closed window
*
D Vertical clearance to ventilated soffit, located
*
above terminal within horizontal distance of
2 ft. (61 cm) from center line of terminal
E Clearance to unventilated soffit
*
F Clearance to outside corner
*
G Clearance to inside corner
*
H Clearance to each side of center line extended
*
above meter/regulator assembly
I Clearance to service regulator vent outlet
*
J Clearance to non-mechanical air supply
12″ (30 cm)
inlet to building or combustion air inlet
to any other appliance
K Clearance to a mechanical air supply 3′ (91 cm) above
inlet
if w/i 10 ft. (3 m)
horizontally
L Clearance above paved sidewalk/paved
*
driveway located on public property
M Clearance under veranda, porch, deck, balcony
*
*For clearances not specified in ANSI Z223.1/NFPA 54 or
CSA B149.1, clearances are in accordance with local
installation codes and the requirements of the gas supplier.
24
Flue Terminal Clearances – Exterior Models
U.S.
DIM DESCRIPTION
Installations
A Clearance above grade, veranda, porch,
12″ (30 cm)
deck, or balcony
B Clearance to window/door that may be open 12″ (30 cm)
C Clearance to permanently closed window
*
D Vertical clearance to ventilated soffit, located
*
above terminal within horizontal distance of
2 ft. (61 cm) from center line of terminal
E Clearance to unventilated soffit
*
F Clearance to outside corner
*
G Clearance to inside corner
*
H Clearance to each side of center line extended
*
above meter/regulator assembly
I Clearance to service regulator vent outlet
*
J Clearance to non-mechanical air supply
12″ (30 cm)
inlet to building or combustion air inlet
to any other appliance
K Clearance to a mechanical air supply 3′ (91 cm) above
inlet
if w/i 10 ft. (3 m)
horizontally
L Clearance above paved sidewalk/paved
*
driveway located on public property
M Clearance under veranda, porch, deck, balcony
*
*For clearances not specified in ANSI Z223.1/NFPA 54 or
CSA B149.1, clearances are in accordance with local
installation codes and the requirements of the gas supplier.
25
For more information visit
www.americanwaterheater.com